Licox Pmo Brain Monitoring System

K040235510(k) TraditionalCleared Apr 20, 200478-day reviewClass II21 CFR 882.1620Recalls 12

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Integra LifeSciences Corporation · GWM Device, Monitoring, Intracranial Pressure

Cleared on Apr 20, 2004 as substantially equivalent to K002765 (Integra Neurosciences, 2000) and 1 other predicate after a 78-day review. Its family tree reaches back 2 generations to 2000. 2 later devices descend from it. It has been recalled 12 times.

Decided
Apr 20, 2004
Review
78 days
Class
Class II
Product code
GWM
Recalls
12
Predicates
2

Its longest line of descent runs back 2 generations to K002765 (2000). 2 later devices descend from it, 2 citing it directly.

  1. Root · 2 generations backK002765 Licox CMP Monitor-AC3.1, Licox Imc Oxygen Catheters-CC1,CC1.SB…Integra Neurosciences · 2000 · Recalled
  2. 1 generation backK020558 Licox CC1.G2 Brain Oxygen Catheter-MicroprobeIntegra Neurosciences · 2002
  3. This deviceK040235 Licox Pmo Brain Monitoring SystemIntegra LifeSciences Corporation · 2004
  4. Descendant · cites it directly · 0 of its ownK131184 Integra Licox PTO2 MonitorIntegra Lifesciences Corp. · 2013 · Recalled
  5. Descendant · cites it directly · 0 of its ownK053244 Licox IT2 Complete Brain Tunneling Probe KitIntegra Lifesciences Corp. · 2006 · Recalled

Most influential descendants

Showing 2 of 2 · See all
  • K131184Integra Licox PTO2 MonitorIntegra Lifesciences Corp. · 2013 · cites it directly0descendants
  • K053244Licox IT2 Complete Brain Tunneling Probe KitIntegra Lifesciences Corp. · 2006 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K002765Licox CMP Monitor-AC3.1, Licox Imc Oxygen Catheters-CC1,CC1.SB Luicox Imc…Integra Neurosciences20003
−1K020558Licox CC1.G2 Brain Oxygen Catheter-MicroprobeIntegra Neurosciences2002—
0 (this device)K040235Licox Pmo Brain Monitoring SystemIntegra LifeSciences Corporation2004—
+1K131184Integra Licox PTO2 MonitorIntegra Lifesciences Corp.20135
+1K053244Licox IT2 Complete Brain Tunneling Probe KitIntegra Lifesciences Corp.20061

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200610
201310
FIG. 1 — Lineage of K040235, 2000–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GWM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GWM device

  1. #1 K252241 Pressio 3 Multi-parameter Neuromonitoring Systemscore 12.9 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K002765Licox CMP Monitor-AC3.1, Licox Imc Oxygen Catheters-CC1,CC1.SB Luicox Imc Introducer…
Summary page 1
…antially equivalent to those of a legally marketed predicate device, the LICOX Brain Oxygen Monitoring System, which was cleared to market under 510(k) K002765 and 510(k) K020558. Both devices were designed and are manufactured by the same company, GMSmbH, Kiel-Mielkend…
Integra Neurosciences20003
*K020558Licox CC1.G2 Brain Oxygen Catheter-Microprobe
Summary page 1
…to those of a legally marketed predicate device, the LICOX Brain Oxygen Monitoring System, which was cleared to market under 510(k) K002765 and 510(k) K020558. Both devices were designed and are manufactured by the same company, GMSmbH, Kiel-Mielkendorf, Germany, which…
Integra Neurosciences2002—

Also cleared against K002765: 8 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K131184Integra Licox PTO2 MonitorIntegra Lifesciences Corp.20130
K053244Licox IT2 Complete Brain Tunneling Probe KitIntegra Lifesciences Corp.20060

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Nov 7, 2014Class IIZ-0831-2015Device DesignDue to a complaint, it was determined that multiple lots of Licox catheters manufactured since October 29, 2013 contained a smart card which was programmed with an inaccurate lkN2 value.
Jun 11, 2013Class IIZ-0061-2014Nonconforming Material/ComponentIntegra LifeSciences Corporation has determined that there is a possibility that some lots of Licox CMP Brain Tissue Oxygen and Temperature Catheter Kits contain a hex wrench that does not loosen the set screw on the drill bit.
Jun 11, 2013Class IIZ-0062-2014Nonconforming Material/ComponentIntegra LifeSciences Corporation has determined that there is a possibility that some lots of Licox CMP Brain Tissue Oxygen and Temperature Catheter Kits contain a hex wrench that does not loosen the set screw on the drill bit.
Jun 11, 2013Class IIZ-0054-2014Nonconforming Material/ComponentIntegra LifeSciences Corporation has determined that there is a possibility that some lots of Licox CMP Brain Tissue Oxygen and Temperature Catheter Kits contain a hex wrench that does not loosen the set screw on the drill bit.
Jun 11, 2013Class IIZ-0060-2014Nonconforming Material/ComponentIntegra LifeSciences Corporation has determined that there is a possibility that some lots of Licox CMP Brain Tissue Oxygen and Temperature Catheter Kits contain a hex wrench that does not loosen the set screw on the drill bit.
Jun 11, 2013Class IIZ-0055-2014Nonconforming Material/ComponentIntegra LifeSciences Corporation has determined that there is a possibility that some lots of Licox CMP Brain Tissue Oxygen and Temperature Catheter Kits contain a hex wrench that does not loosen the set screw on the drill bit.
Jun 11, 2013Class IIZ-0056-2014Nonconforming Material/ComponentIntegra LifeSciences Corporation has determined that there is a possibility that some lots of Licox CMP Brain Tissue Oxygen and Temperature Catheter Kits contain a hex wrench that does not loosen the set screw on the drill bit.
Jun 11, 2013Class IIZ-0057-2014Nonconforming Material/ComponentIntegra LifeSciences Corporation has determined that there is a possibility that some lots of Licox CMP Brain Tissue Oxygen and Temperature Catheter Kits contain a hex wrench that does not loosen the set screw on the drill bit.
Jun 11, 2013Class IIZ-0059-2014Nonconforming Material/ComponentIntegra LifeSciences Corporation has determined that there is a possibility that some lots of Licox CMP Brain Tissue Oxygen and Temperature Catheter Kits contain a hex wrench that does not loosen the set screw on the drill bit.
Jun 11, 2013Class IIZ-0063-2014Nonconforming Material/ComponentIntegra LifeSciences Corporation has determined that there is a possibility that some lots of Licox CMP Brain Tissue Oxygen and Temperature Catheter Kits contain a hex wrench that does not loosen the set screw on the drill bit.
Sep 15, 2010Not classifiedZ-0161-2011Employee errorIncorrect expiration date - The outer boxes of the IP2P Licox Complete Kit for Cerebral Pressure, Temperature and ICP Monitoring Probes, Lot 250210A are labeled with an incorrect shelf life date (10 months too long).
Feb 18, 2010Not classifiedZ-1422-2010Process controlOne probe that had failed a product release test was inadvertently packaged and released into inventory in Integra's distribution center.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 4 years and passes through 2 companies; a new generation was cleared every 2.1 years on median.
  • 1 of the 2 ancestors has a recall of any class.
  • Of its descendants, K131184 (Integra Lifesciences Corp., 2013) has gone furthest, with 0 descendants of its own.
  • 8 other devices also cite its predicate K002765.

How does its category compare?

All GWM devices

GWM Device, Monitoring, Intracranial Pressure: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GWM

1in 2025

2007: 22008: 22009: 12010: 22011: 32012: 42013: 22014: 22016: 32017: 32018: 12019: 22020: 32021: 22024: 22025: 12026 (partial year): 1
2007high 4 (2012) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GWM

30in 2020

2011: 123 days median2012: 100 days median2016: 192 days median2017: 37 days median2020: 30 days median
2007high 192 (2016) · low 30 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GWM

3in 2025

2008: 12010: 92011: 62012: 12013: 122014: 22019: 12023: 1, 1 Class I2024: 4, 2 Class I2025: 3
2007high 12 (2013) · low 0 (2007)2026

Class I (3 since 2007) Class II/III not classified

Adverse event reports per year · GWM

441in 2025

2007: 1262008: 1052009: 1172010: 1042011: 1842012: 1512013: 1202014: 3602015: 4862016: 4192017: 4452018: 3022019: 2602020: 2682021: 2112022: 4242023: 7442024: 6412025: 441
2007high 744 (2023) · low 104 (2010)2025

MAUDE reports naming product code GWM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—0126
20082—1105
20091—0117
20102—9104
201131236184
201241001151
20132—12120
20142—2360
20150—0486
201631920419
20173370445
20181—0302
20192—1260
20203300268
20212—0211
20220—0424
20230—1 (1)744
20242—4 (2)641
20251—3441
20261—0—

What is it indicated for?

The LICOX PMO Brain Oxygen Monitoring System measures intracranial oxygen and temperature and is intended as an adjunct monitor of trends of these parameters, indicating the perfusion status of cerebral tissue local to sensor placement. LICOX System values are relative within an individual, and should not be used as the sole basis for decisions as to diagnosis or therapy. It is intended to provide data additional to that obtained by current clinical practice in cases where hypoxia or ischemia are a concern.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K040235: Licox Pmo Brain Monitoring System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K040235

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026