510(k) Report

510(k) · Cleared

Recalled · 2010

Innova 2000 and Innova 2000S (Mobile Version)

K024200510(k) SpecialCleared Jan 16, 200327-day reviewClass II21 CFR 892.1650Recalls 7

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ge Medical Systems, Inc. · OWB Interventional Fluoroscopic X-Ray System

Cleared on Jan 16, 2003 as substantially equivalent to K022322 (Ge Medical Systems, Inc., 2002) after a 27-day review. Its family tree reaches back 3 generations to 1989. It has been recalled 7 times.

Decided
Jan 16, 2003
Review
27 days
Class
Class II
Product code
OWB
Recalls
7
Predicates
1

Its longest line of descent runs back 3 generations to K890348 (1989). 6 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1995: 2 other ancestors1993: 1 other ancestorK890348 · LC, Cardiac Positioner #B5078A · General Electric Co. · 1989 · recalledK993037 · LCV+ Version 2 · Ge Medical Systems, Inc. · 2000 · recalledK022322 · Innova and Innova 2000 S · Ge Medical Systems, Inc. · 2002 · recalled19851990199520002005
  1. Root · 3 generations backK890348 LC, Cardiac Positioner #B5078AGeneral Electric Co. · 1989 · Recalled
  2. 2 generations backK993037 LCV+ Version 2Ge Medical Systems, Inc. · 2000 · Recalled
  3. 1 generation backK022322 Innova and Innova 2000 SGe Medical Systems, Inc. · 2002 · Recalled
  4. This deviceK024200 Innova 2000 and Innova 2000S (Mobile Version)Ge Medical Systems, Inc. · 2003
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K890348LC, Cardiac Positioner #B5078AGeneral Electric Co.19895
−2K993037LCV+ Version 2Ge Medical Systems, Inc.20006
−1K022322Innova and Innova 2000 SGe Medical Systems, Inc.20027
0 (this device)K024200Innova 2000 and Innova 2000S (Mobile Version)Ge Medical Systems, Inc.2003—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199310
199520
FIG. 1 — Lineage of K024200, 1989–2003Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OWB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OWB device

  1. #1 K251602 Alphenix, INFX-8000V/B, INFX-8000V/S, V9.6…score 18.3 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K022322Innova and Innova 2000 S
Summary page 1
…rue de la Miniére 78530 Buc Cedex. France Distributed by: GE Medical Systems PO Box 414 Milwaukee. WI 53201 Marketed Device: Innova 2000 and Innova 2000S cleared under K022322. Device Description: The Innova 2000 and 2000S (Mobile version) - hereafter referred to as Mobile Innova 2000 and Innova 2000S -…
Ge Medical Systems, Inc.20027

Also cleared against K022322: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 10, 2010Not classifiedZ-2238-2010OtherA hardware component (potentiometer and encoder)mismatch in Innova 2000 digital fluoroscopic imaging systems may cause a Source to Image Distance (SID) failure, which will cause the imager to fail to detect the distance between the imager…
Dec 22, 2009Not classifiedZ-0620-2010Device DesignPotential table rotation of Omega IV and Omega V tables affecting Advantx-E and Innova 2000, 2100IQ, 3100, 3100IQ, 4100, 4100IQ, 2121IQ and 3131IQ cardiovascular X-ray imaging systems. Due to potential weakness of some table rotational…
Aug 6, 2009Not classifiedZ-0393-2011Nonconforming Material/ComponentGE Healthcare has become aware of a potential video splitter failure with certain Innova 2000 and 4100 X-ray systems that may impact patient safety. A potential video splitter failure inside the GE equipment cabinet could occur with no…
Jul 31, 2009Not classifiedZ-2240-2009Component design/selectionGE Healthcare has recently became aware of a potential power supply failure with the Innova 2000, 3100 and 4100 systems that may impact patient safety. A potential power supply failure inside the GE equipment cabinet could occur with no…
Jul 25, 2008Not classifiedZ-2435-2008Device DesignThe charger and / or battery of the PDB may fail earlier than expected with no advance warning and thus cause the system to shut down.
Jan 14, 2008Not classifiedZ-2042-2008Process controlRisk of sudden table drop on Omega IV and Omega V tables on GE Healthcare Advantx-E as well as on Innova 2000, 2100IQ, 3100/3100 IQ and 4100/4100IQ cardiovascular X-ray system
Mar 6, 2006Not classifiedZ-0896-06OtherIncorrect screws were used for mounting the detector which may lead to a possible part falling onto a patient.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 2 companies; a new generation was cleared every 2.6 years on median.
  • 4 of the 6 ancestors have a recall of any class.
  • 2 other devices also cite its predicate K022322.

How does its category compare?

All OWB devices

OWB Interventional Fluoroscopic X-Ray System: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · OWB

22in 2025

2007: 32008: 42009: 92010: 72011: 62012: 62013: 112014: 152015: 112016: 162017: 202018: 232019: 92020: 162021: 242022: 212023: 122024: 132025: 222026 (partial year): 15
2007high 24 (2021) · low 3 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OWB

148in 2025

2007: 52 days median2008: 135 days median2009: 99 days median2010: 66 days median2011: 79 days median2012: 37 days median2013: 119 days median2014: 158 days median2015: 66 days median2016: 103 days median2017: 76 days median2018: 54 days median2019: 174 days median2020: 53 days median2021: 60 days median2022: 90 days median2023: 152 days median2024: 126 days median2025: 148 days median2026 (partial year): 221 days median
2007high 221 (2026) · low 37 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OWB

42so far in 2026, the most since 2007

2008: 12013: 102014: 92015: 352016: 132017: 132018: 62019: 72020: 82021: 312022: 242023: 222024: 112025: 302026 (partial year): 42
2007high 42 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OWB

14,008in 2025

2007: 12011: 12012: 12013: 272014: 1032015: 2,1342016: 4,0742017: 1,6042018: 1,4492019: 1,5582020: 1,5812021: 1,9812022: 2,9322023: 7,6042024: 7,9422025: 14,008
2007high 14,008 (2025) · low 0 (2008)2025

MAUDE reports naming product code OWB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735201
2008413510
200999900
201076600
201167901
201263701
2013111191027
2014151589103
20151166352,134
201616103134,074
20172076131,604
2018235461,449
2019917471,558
2020165381,581
20212460311,981
20222190242,932
202312152227,604
202413126117,942
2025221483014,008
20261522142—

What is it indicated for?

The Digital Fluoroscopic Imaging Systems are indicated for use in diagnostic and interventional cardiac angiography and optionally, rotational cardiac angiography procedures of human anatomy. It is intended to replace image intensifier fluoroscopic systems in all diagnostic or interventional cardiac angiography procedures. They can be operated in a mobile as well as a fixed site environment.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K024200: Innova 2000 and Innova 2000S (Mobile Version).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K024200

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026