510(k) · Cleared
ClearedBI-Angular Shoulder System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Biomet, Inc. · MBF Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented
Cleared on Nov 20, 2003 as substantially equivalent to K030710 (Biomet, Inc., 2003) and 1 other predicate after a 64-day review. Its family tree reaches back 4 generations to 1980. 10 later devices descend from it.
- Decided
- Nov 20, 2003
- Review
- 64 days
- Class
- Class II
- Product code
- MBF
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 4 generations to K800494 (1980). 16 ancestors in all. 10 later devices descend from it, 1 citing it directly.
- Root · 4 generations backK800494 New Jersey Hemiarthroplasty Sholder ProsDepuy, Inc. · 1980
- 3 generations backK991585 Bipolar Shoulder ProsthesisBiomet, Inc. · 1999
- 2 generations backK002998 Biomet BI-Polar Shoulder SystemBiomet, Inc. · 2000 · Recalled
- 1 generation backK030710 Bio-Modular Shoulder SystemBiomet, Inc. · 2003 · Recalled
- This deviceK032895 BI-Angular Shoulder SystemBiomet, Inc. · 2003
- Descendant · cites it directly · 9 of its ownK042321 Mosaic Non-Modular Proximal Body and Eas Offset Modular Humeral HeadBiomet Manufacturing Corp · 2005
- Descendant · 2 generations on · 7 of its ownK111746 Comprehensive Segmental Revision System (SRS)Biomet, Inc. · 2011 · Recalled
- Descendant · 3 generations on · 5 of its ownK143659 Equinoxe Mega ProsthesisExactech, Inc. · 2015
- Descendant · 3 generations on · 3 of its ownK153398 Comprehensive SRS/Nexel ElbowBiomet Manufacturing Corp · 2016
- Descendant · 3 generations on · 2 of its ownK173411 Comprehensive Segmental Revision System (SRS)Biomet Manufacturing Corp · 2018
Showing 5 of 10 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 10 · See all- K042321Mosaic Non-Modular Proximal Body and Eas Offset Modular Humeral HeadBiomet Manufacturing Corp · 2005 · cites it directly9descendants
- K111746Comprehensive Segmental Revision System (SRS)Biomet, Inc. · 2011 · 2 generations on7descendants
- K143659Equinoxe Mega ProsthesisExactech, Inc. · 2015 · 3 generations on5descendants
- K153398Comprehensive SRS/Nexel ElbowBiomet Manufacturing Corp · 2016 · 3 generations on3descendants
- K173411Comprehensive Segmental Revision System (SRS)Biomet Manufacturing Corp · 2018 · 3 generations on2descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K800494 | New Jersey Hemiarthroplasty Sholder Pros | Depuy, Inc. | 1980 | — |
| −3 | K991585 | Bipolar Shoulder Prosthesis | Biomet, Inc. | 1999 | — |
| −2 | K002998 | Biomet BI-Polar Shoulder System | Biomet, Inc. | 2000 | 1 |
| −1 | K030710 | Bio-Modular Shoulder System | Biomet, Inc. | 2003 | 1 |
| 0 (this device) | K032895 | BI-Angular Shoulder System | Biomet, Inc. | 2003 | — |
| +1 | K042321 | Mosaic Non-Modular Proximal Body and Eas Offset Modular Humeral Head | Biomet Manufacturing Corp | 2005 | — |
| +2 | K111746 | Comprehensive Segmental Revision System (SRS) | Biomet, Inc. | 2011 | 1 |
| +3 | K143659 | Equinoxe Mega Prosthesis | Exactech, Inc. | 2015 | — |
| +3 | K153398 | Comprehensive SRS/Nexel Elbow | Biomet Manufacturing Corp | 2016 | — |
| +3 | K173411 | Comprehensive Segmental Revision System (SRS) | Biomet Manufacturing Corp | 2018 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1980 | 1 | 0 |
| 1987 | 1 | 0 |
| 1992 | 2 | 0 |
| 1994 | 2 | 0 |
| 1995 | 1 | 0 |
| 1998 | 2 | 0 |
| 1999 | 2 | 0 |
| 2001 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2005 | 1 | 0 |
| 2011 | 2 | 0 |
| 2015 | 1 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
| 2018 | 1 | 0 |
| 2023 | 1 | 0 |
| 2025 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MBF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MBF device
- #1 K202716 Ignite Anatomic Shoulder Systemscore 20.3 · 14 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K030710 | Bio-Modular Shoulder System | 2003 |
| * | K925613 | Proximal Humeral Replacement SystemSummary page 1…CFR Section 888.3690) Legally Marketed Devices To Which Substantial Equivalence Is Claimed: Bio-Modula@ Shoulder System - KO30710 Proximal Humeral Component - K925613 Device Description: The Bi-Angular43 Shoulder System is composed of a titanium alloy humeral stem with a modular humeral head wh… | 1994 |
What descends from it? (10)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K042321 | Mosaic Non-Modular Proximal Body and Eas Offset Modular Humeral Head | 2005 | 9 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 23 years and passes through 2 companies; a new generation was cleared every 2.7 years on median.
- 3 of the 16 ancestors have a recall of any class.
- Of its descendants, K042321 (Biomet Manufacturing Corp, 2005) has gone furthest, with 9 descendants of its own.
- 19 other devices also cite its predicate K030710.
How does its category compare?
All MBF devicesMBF Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MBF
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MBF
144in 2023
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MBF
1in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MBF
255in 2025
MAUDE reports naming product code MBF, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 2 |
| 2008 | 1 | — | 0 | 7 |
| 2009 | 1 | — | 1 | 16 |
| 2010 | 0 | — | 0 | 24 |
| 2011 | 0 | — | 0 | 32 |
| 2012 | 2 | — | 0 | 30 |
| 2013 | 1 | — | 0 | 40 |
| 2014 | 1 | — | 0 | 28 |
| 2015 | 0 | — | 0 | 49 |
| 2016 | 0 | — | 0 | 85 |
| 2017 | 2 | — | 1 | 193 |
| 2018 | 1 | — | 1 | 99 |
| 2019 | 2 | — | 2 | 47 |
| 2020 | 2 | — | 0 | 24 |
| 2021 | 1 | — | 0 | 36 |
| 2022 | 4 | 164 | 8 | 114 |
| 2023 | 4 | 144 | 1 | 143 |
| 2024 | 2 | — | 0 | 164 |
| 2025 | 2 | — | 0 | 255 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
1) Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis
2) Rheumatoid arthritis
3) Revision where other devices or treatments have failed
4) Correction of functional deformity
5) Fractures of the proximal humerus, where other methods of treatment are deemed inadequate
6) Difficult clinical management problems, including cuff arthropathy, where other methods of treatment may not be suitable or may be inadequate
Devices with surface coatings are indicated for cemented or uncemented biological fixation application. Non-coated (InterlokQ) devices and all polyethylene components are indicated for cemented application only.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K032895 · printed Nov 6, 2026
Cite this page
510(k) Report. “K032895: BI-Angular Shoulder System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K032895