510(k) Report

510(k) · Cleared

Cleared

I-Flow Elastomeric Pump (on-Q, Painbuster, C-Bloc, Homepump)

K040337510(k) TraditionalCleared May 24, 2004103-day reviewClass II21 CFR 880.5725

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

I-Flow Corp. · MEB Pump, Infusion, Elastomeric

Cleared on May 24, 2004 after a 103-day review. The FDA summary names no predicate by number. 1 of the 19 devices in its family, counting itself, has a Class I recall. 18 later devices descend from it.

Decided
May 24, 2004
Review
103 days
Class
Class II
Product code
MEB
Recalls
None
Predicates
0

18 later devices descend from it, 6 citing it directly. 1 of the 19 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2004: 2 descendants cleared2006: 1 descendant cleared2005: 5 descendants cleared2008: 2 descendants cleared, 1 with a Class I recall12007: 2 descendants cleared2016: 1 descendant cleared2013: 1 descendant cleared2019: 1 descendant cleared2024: 2 descendants cleared2026: 1 descendant cleared200020052010201520202025
  1. This deviceK040337 I-Flow Elastomeric Pump (on-Q, Painbuster, C-Bloc, Homepump)I-Flow Corp. · 2004
  2. Descendant · cites it directly · 9 of its ownK052117 I-Flow Elastomeric Pump (on-Q, Painbuster, C-Block, Homepump…I-Flow Corp. · 2005 · Recalled
  3. Descendant · cites it directly · 7 of its ownK042228 Beeline Motiv, Propolis, PcaMckinley, Inc. · 2004
  4. Descendant · cites it directly · 6 of its ownK050770 Modification to Accufuser, Accufuser Plus Standard Procedure KitMckinley Medical, LLC · 2005
  5. Descendant · 2 generations on · 5 of its ownK052451 MPS Acacia Medflo Elastomeric PumpMps Acacia · 2005
  6. Descendant · 2 generations on · 4 of its ownK081905 Accuflow and Accuflux Elastomeric Infusion PumpWestmed, Inc. · 2008 · Recalled (Class I)

Showing 5 of 18 descendants. See all descendants

Descendants cleared per year

2004: 22005: 52006: 12007: 22008: 22013: 12016: 12019: 12024: 22026: 1
2004high 5 (2005) · low 0 (2009)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 18 · See all
  • K052117I-Flow Elastomeric Pump (on-Q, Painbuster, C-Block, Homepump, Easypump)I-Flow Corp. · 2005 · cites it directly9descendants
  • K042228Beeline Motiv, Propolis, PcaMckinley, Inc. · 2004 · cites it directly7descendants
  • K050770Modification to Accufuser, Accufuser Plus Standard Procedure KitMckinley Medical, LLC · 2005 · cites it directly6descendants
  • K052451MPS Acacia Medflo Elastomeric PumpMps Acacia · 2005 · 2 generations on5descendants
  • K081905Accuflow and Accuflux Elastomeric Infusion PumpWestmed, Inc. · 2008 · 2 generations on4descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K040337I-Flow Elastomeric Pump (on-Q, Painbuster, C-Bloc, Homepump)I-Flow Corp.2004—
+1K052117I-Flow Elastomeric Pump (on-Q, Painbuster, C-Block, Homepump, Easypump)I-Flow Corp.20053
+1K042228Beeline Motiv, Propolis, PcaMckinley, Inc.2004—
+1K050770Modification to Accufuser, Accufuser Plus Standard Procedure KitMckinley Medical, LLC2005—
+2K052451MPS Acacia Medflo Elastomeric PumpMps Acacia2005—
+2K081905Accuflow and Accuflux Elastomeric Infusion PumpWestmed, Inc.2008Class I

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200420
200550
200610
200720
200821
201310
201610
201910
202420
202610
FIG. 1 — Lineage of K040337, 2004–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MEB device

  1. #1 K250234 SMARTeZ™ Elastomeric Infusion Pump (RS series)score 14.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

The FDA summary names no predicate by number.

What descends from it? (18)

See all 18

6 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K052117I-Flow Elastomeric Pump (on-Q, Painbuster, C-Block, Homepump, Easypump)I-Flow Corp.20059
K042228Beeline Motiv, Propolis, PcaMckinley, Inc.20047
K050770Modification to Accufuser, Accufuser Plus Standard Procedure KitMckinley Medical, LLC20056
K042405PAINPUMP1; PAINPUMP2Stryker Corp.20043
K043466PAINPUMP2Stryker Instruments20051
K060933Solace Post-Operative Pain Relief Infusion SystemApex Medical Technologies, Inc.20060

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K081905Accuflow and Accuflux Elastomeric Infusion PumpWestmed, Inc. · 2008 · 2 generations on · ◆ in the 2008 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • Of its descendants, K052117 (I-Flow Corp., 2005) has gone furthest, with 9 descendants of its own.

How does its category compare?

All MEB devices

MEB Pump, Infusion, Elastomeric: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MEB

2in 2024

2007: 52008: 22009: 12013: 12014: 12016: 12019: 12024: 22026 (partial year): 1
2007high 5 (2007) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MEB

42in 2007

2007: 42 days median
2007high 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MEB

17in 2018

2007: 12008: 32009: 482010: 22011: 8, 1 Class I2013: 2, 1 Class I2018: 17
2007high 48 (2009) · low 0 (2012)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · MEB

1,408in 2025

2007: 1102008: 4442009: 7982010: 1,8272011: 2,2652012: 1,9762013: 1,9562014: 2,6952015: 2,9802016: 2,1472017: 1,6532018: 1,4732019: 9742020: 2,7322021: 1,8022022: 1,2882023: 1,2482024: 1,4242025: 1,408
2007high 2,980 (2015) · low 110 (2007)2025

MAUDE reports naming product code MEB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20075421110
20082—3444
20091—48798
20100—21,827
20110—8 (1)2,265
20120—01,976
20131—2 (1)1,956
20141—02,695
20150—02,980
20161—02,147
20170—01,653
20180—171,473
20191—0974
20200—02,732
20210—01,802
20220—01,288
20230—01,248
20242—01,424
20250—01,408
20261—0—

What is it indicated for?

1. The I-Flow Elastomeric Pump is intended for continuous and/or intermittent infusion of medications for general infusion use, including antibiotic delivery, chemotherapy and pain management. Routes of administration include the following: intravenous, intra-arterial, subcutaneous, intramuscular and epidural. 2. The I-Flow Elastomeric Pump is also intended for continuous and/or intermittent delivery of medication (such as local anesthetics or narcotics)…

Read the full statement (123 words)

1. The I-Flow Elastomeric Pump is intended for continuous and/or intermittent infusion of medications for general infusion use, including antibiotic delivery, chemotherapy and pain management. Routes of administration include the following: intravenous, intra-arterial, subcutaneous, intramuscular and epidural.

2. The I-Flow Elastomeric Pump is also intended for continuous and/or intermittent delivery of medication (such as local anesthetics or narcotics) to surgical wound sites and/or close proximity to nerves for preoperative, perioperative and postoperative regional anesthesia and pain management. Routes of administration may be intraoperative, perineural or percutaneous.

3. The I-Flow Elastomeric Pump is also intended to significantly decrease narcotic use and pain when used to deliver local anesthetics to surgical wound sites or close proximity to nerves when compared with narcotic only pain management.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K040337: I-Flow Elastomeric Pump (on-Q, Painbuster, C-Bloc, Homepump).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K040337

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026