Evis Exera Bronchovideoscope, Olympus XBF-160Y3AC, XBF-1T160Y3AC,XBF-Q160Y2AC

K050220510(k) TraditionalCleared Feb 10, 200510-day reviewClass II21 CFR 874.4680Recalls 5 (2 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Olympus Medical Systems Corporation · EOQ Bronchoscope (Flexible Or Rigid)

Cleared on Feb 10, 2005 as substantially equivalent to K023984 (The Olympus Optical Co., 2003) and 1 other predicate after a 10-day review. Its family tree reaches back 5 generations to 1984. 2 of the 12 devices in its family, counting itself, have a Class I recall. It has been recalled 5 times, including 2 Class I recalls.

Decided
Feb 10, 2005
Review
10 days
Class
Class II
Product code
EOQ
Recalls
5 (2 Class I)
Predicates
2

Its longest line of descent runs back 5 generations to K844002 (1984). 11 ancestors in all. No later device cites it as a predicate yet. 2 of the 12 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year cleared 2003: 1 other ancestor, 1 with a Class I recall11996: 1 other ancestor1991: 1 other ancestor1994: 1 other ancestor1993: 1 other ancestor1997: 1 other ancestorK844002 · HU-Friedy Ims Cassette System · Hu-Friedy Mfg. Co., Inc. · 1984K980065 · C/T Med-Systems Cassette System · C/T Med System, Ltd. · 1998K990761 · Tuttnauer Mini Container Cassette, Tuttnauer Standard Case Cassette · Tuttnauer U.S.A Co, Ltd. · 1999K012105 · Polyvac Surgical Instrument Delivery System · Symmetry Medical, Inc. · 2002K033222 · Olympus Sterilization Trays · Olympus Winter & Ibe GmbH · 2004198019851990199520002005
  1. Root · 5 generations backK844002 HU-Friedy Ims Cassette SystemHu-Friedy Mfg. Co., Inc. · 1984
  2. 4 generations backK980065 C/T Med-Systems Cassette SystemC/T Med System, Ltd. · 1998
  3. 3 generations backK990761 Tuttnauer Mini Container Cassette, Tuttnauer Standard Case CassetteTuttnauer U.S.A Co, Ltd. · 1999
  4. 2 generations backK012105 Polyvac Surgical Instrument Delivery SystemSymmetry Medical, Inc. · 2002
  5. 1 generation backK033222 Olympus Sterilization TraysOlympus Winter & Ibe GmbH · 2004
  6. This deviceK050220 Evis Exera Bronchovideoscope, Olympus XBF-160Y3AC…Olympus Medical Systems Corporation · 2005

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K844002HU-Friedy Ims Cassette SystemHu-Friedy Mfg. Co., Inc.1984—
−4K980065C/T Med-Systems Cassette SystemC/T Med System, Ltd.1998—
−3K990761Tuttnauer Mini Container Cassette, Tuttnauer Standard Case CassetteTuttnauer U.S.A Co, Ltd.1999—
−2K012105Polyvac Surgical Instrument Delivery SystemSymmetry Medical, Inc.2002—
−1K033222Olympus Sterilization TraysOlympus Winter & Ibe GmbH2004—
0 (this device)K050220Evis Exera Bronchovideoscope, Olympus XBF-160Y3AC, XBF-1T160Y3AC,XBF-Q160Y2ACOlympus Medical Systems Corporation2005—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199310
199410
199610
199710
200311
FIG. 1 — Lineage of K050220, 1984–2005Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new EOQ device

  1. #1 K223299 Ambu® aScope™ 5 Broncho HD 5.0/2.2, Ambu®…score 18.4 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K023984Modification to Olympus Bronchoscopes BF-40 Series, BF-240 Series, and BF-160 Series
Summary page 2
…cessories 21 CFR 874.4680 I EOQ 3. Predicate Device Predicate Device Name Manufacturer 510(k) Number EVIS EXERA Bronchovideoscope Olympus Corporation K023984 Olympus BF type 160 EVIS EXERA Bronchovideoscope Olympus Corporation K023984 Olympus BF type 1T160 Olympus Sterilization Trays…
The Olympus Optical Co.2003Class I
*K033222Olympus Sterilization Trays
Summary page 2
…tion K023984 Olympus BF type 160 EVIS EXERA Bronchovideoscope Olympus Corporation K023984 Olympus BF type 1T160 Olympus Sterilization Trays Olympus Winter & Ibe GMBH | K033222 4. Device Description The subject devices, Olympus EVIS EXERA Bronchovideoscope XBF-160Y3AC, XBF-1T160Y3AC, and XBF-Q160Y2AC are…
Olympus Winter & Ibe GmbH2004—

Also cleared against K023984: 8 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (2 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 11, 2025Class IZ-0062-2026Device DesignAdditional IFU updates to provide further clarification on safe and effective use of bronchoscopes when used in conjunction with laser, argon plasma coagulation, and high-frequency therapy equipment.
Oct 12, 2023Class IZ-0190-2024Under Investigation by firmThere is a risk of endobronchial combustion if high-frequency cauterization is performed while supplying oxygen [and/or] the electrode section of the electrosurgical accessory is too close to the distal end of the endoscope.
Jul 27, 2023Class IIZ-2492-2023Labeling Change ControlComplaint of endoscope model becoming lodged in the endotracheal tube connector due to diameter being too large.
Aug 16, 2021Class IIZ-2573-2021Reprocessing ControlsThe firm is issuing validated, new reprocessing instructions according to the FDA 2015 guidance, "Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling."
Aug 8, 2018Class IIZ-3302-2018OtherThe attachment of non-Olympus accessories to the bronchoscope s instrument channel port may have resulted in more applied force than expected and lead to loosening of the instrument channel port.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K023984Modification to Olympus Bronchoscopes BF-40 Series, BF-240 Series, and BF-160 SeriesThe Olympus Optical Co. · 2003 · Direct predicate · ◆ in the 2003 ancestors bar of FIG. 114 Class I recalls

What does this lineage say?

  • The line of descent spans 21 years and passes through 6 companies; a new generation was cleared every 2.0 years on median.
  • 3 of the 11 ancestors have a recall of any class; 1 has a Class I recall.
  • 8 other devices also cite its predicate K023984.

How does its category compare?

All EOQ devices

EOQ Bronchoscope (Flexible Or Rigid): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · EOQ

20in 2025

2007: 22008: 22009: 32012: 22013: 42014: 32015: 62016: 32017: 42018: 72019: 112020: 102021: 152022: 112023: 122024: 132025: 202026 (partial year): 9
2007high 20 (2025) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · EOQ

147in 2025

2009: 24 days median2013: 178 days median2014: 302 days median2015: 206 days median2016: 262 days median2017: 136 days median2018: 212 days median2019: 147 days median2020: 103 days median2021: 169 days median2022: 134 days median2023: 160 days median2024: 130 days median2025: 147 days median2026 (partial year): 206 days median
2007high 302 (2014) · low 24 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · EOQ

25in 2025

2011: 12012: 42016: 12019: 12020: 12021: 92022: 52023: 18, 4 Class I2024: 42025: 25, 24 Class I
2007high 25 (2025) · low 0 (2007)2026

Class I (28 since 2007) Class II/III not classified

Adverse event reports per year · EOQ

6,546in 2025

2007: 392008: 872009: 1142010: 1002011: 962012: 932013: 932014: 982015: 1322016: 2972017: 3372018: 2792019: 6542020: 5152021: 1,3582022: 2,5412023: 5,0642024: 6,0512025: 6,546
2007high 6,546 (2025) · low 39 (2007)2025

MAUDE reports naming product code EOQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—039
20082—087
20093240114
20100—0100
20110—196
20122—493
20134178093
20143302098
201562060132
201632621297
201741360337
201872120279
2019111471654
2020101031515
20211516991,358
20221113452,541
20231216018 (4)5,064
20241313046,051
20252014725 (24)6,546
202692060—

What is it indicated for?

These instruments have been designed to be used with an Olympus video system center, light source, documentation equipment, videc monitor, endo-therapy accessories (such as biopsy forceps) and other ancillary equipment for endoscopy and endoscopic surgery within the airways and tracheobronchial tree. The XMAJ-178 is a sterilization tray intended for use in medical facilities to accommodate the Olympus autoclavable Bronchovideoscopes during autoclaving.…

Read the full statement (209 words)

These instruments have been designed to be used with an Olympus video system center, light source, documentation equipment, videc monitor, endo-therapy accessories (such as biopsy forceps) and other ancillary equipment for endoscopy and endoscopic surgery within the airways and tracheobronchial tree.

The XMAJ-178 is a sterilization tray intended for use in medical facilities to accommodate the Olympus autoclavable Bronchovideoscopes during autoclaving.

The MAJ-1214 is attached to the electrical connector on the endoscope to protect the connector from water penetration during reprocessing.

The FB-52C-1 has been designed to be used with an Olympus endoscope to collect tissue within the thoracic and abdominal cavities and the airways and tracheobrochial tree.

This instrument has been designed to be used with Olympus endoscopes to retrieve foreign bodies, caluculi or tissue specimens from the digestive tract, urinary tract, female reproductive tract and respiratory organs.

The Olympus IE-2P magnetic Extractor has been specially designed to be used within the airways and tracheobrochial tree.

These instruments have been designed to be used with an Olympus endoscope to perform endoscopic vascular or submucosal injection within the thoracic and abdominal cavities and the airways and tracheobrochial tree.

These measuring devices have been designed for measuring leisions within the thoracic and abdominal cavities and the airways and tracheobochial tree.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K050220: Evis Exera Bronchovideoscope, Olympus XBF-160Y3AC, XBF-1T160Y3AC,XBF-Q160Y2AC.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K050220

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026