510(k) · Cleared
Recalled · 2006Ambit Push & Play Ambulatory Infusion Pump
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Sorenson Medical, Inc. · FRN Pump, Infusion
Cleared on Dec 8, 2005 as substantially equivalent to K965222 (Microject, Inc., 1997) and 3 other predicates after a 115-day review. Its family tree reaches back 2 generations to 2000. It has been recalled 4 times.
- Decided
- Dec 8, 2005
- Review
- 115 days
- Class
- Class II
- Product code
- FRN
- Recalls
- 4
- Predicates
- 4
Its longest line of descent runs back 2 generations to K002434 (2000). 7 ancestors in all, the oldest K965222 (1997). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K002434 | Palm Pump | Sorenson Medical, Inc. | 2000 | 4 |
| −1 | K033325 | Ambit Continuous Ambulatory Infusion Pump | Sorenson Medical, Inc. | 2003 | 4 |
| 0 (this device) | K052221 | Ambit Push & Play Ambulatory Infusion Pump | Sorenson Medical, Inc. | 2005 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1997 | 1 | 0 |
| 2003 | 2 | 0 |
| 2004 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FRN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FRN device
- #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K965222 | Microject Model Pca-1Summary page 1…Pump/Class II, 80FRN - 21 CFR 880.5725 Trade Names: amnbIT® PreSet Ambulatory Infusion Pump, or amnbIT® Pump Predicate Devices: * The MicroJect PCA Pump K965222 * The Palm Pump, K002434 * The ambIT® Continuous Ambulatory Infusion Pump K033325. Note: These predicate device… | 1997 |
| * | K002434 | Palm PumpSummary page 1…0.5725 Trade Names: amnbIT® PreSet Ambulatory Infusion Pump, or amnbIT® Pump Predicate Devices: * The MicroJect PCA Pump K965222 * The Palm Pump, K002434 * The ambIT® Continuous Ambulatory Infusion Pump K033325. Note: These predicate devices are manufactured by Sorenson M… | 2000 |
| * | K033325 | Ambit Continuous Ambulatory Infusion PumpSummary page 1…, or amnbIT® Pump Predicate Devices: * The MicroJect PCA Pump K965222 * The Palm Pump, K002434 * The ambIT® Continuous Ambulatory Infusion Pump K033325. Note: These predicate devices are manufactured by Sorenson Medical, Inc. * Stryker Pain Pumps 1 & 2 K042405. Not… | 2003 |
| * | K042405 | PAINPUMP1; PAINPUMP2Summary page 1…* The ambIT® Continuous Ambulatory Infusion Pump K033325. Note: These predicate devices are manufactured by Sorenson Medical, Inc. * Stryker Pain Pumps 1 & 2 K042405. Note: These pumps are manufactured by Stryker Instruments. Statement of Intended Use: The amnbIT® PreSet Ambulatory Inf… | 2004 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Oct 10, 2006 | Not classified | Z-0185-2007 | Other | Sterile disposable cassette used with infusion pump may cause an under-infusion when used in a low flow rate therapy of less than 10 ml per hour. |
| Oct 10, 2006 | Not classified | Z-0186-2007 | Other | Sterile disposable cassette used with infusion pump may cause an under-infusion when used in a low flow rate therapy of less than 10 ml per hour. |
| Oct 10, 2006 | Not classified | Z-0188-2007 | Other | Sterile disposable cassette used with infusion pump may cause an under-infusion when used in a low flow rate therapy of less than 10 ml per hour. |
| Oct 10, 2006 | Not classified | Z-0187-2007 | Other | Sterile disposable cassette used with infusion pump may cause an under-infusion when used in a low flow rate therapy of less than 10 ml per hour. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 5 years and passes through 1 company; a new generation was cleared every 3.2 years on median.
- 4 of the 7 ancestors have a recall of any class.
How does its category compare?
All FRN devicesFRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FRN
8in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FRN
172in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FRN
7in 2025
Class I (37 since 2007) Class II/III not classified
Adverse event reports per year · FRN
52,792in 2025
MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 12 | 102 | 15 | 1,086 |
| 2008 | 8 | 89 | 24 | 8,261 |
| 2009 | 9 | 66 | 102 | 1,952 |
| 2010 | 3 | 93 | 37 | 6,133 |
| 2011 | 3 | 103 | 69 | 41,367 |
| 2012 | 4 | 217 | 42 (2) | 15,482 |
| 2013 | 6 | 312 | 22 (3) | 40,082 |
| 2014 | 6 | 172 | 4 (3) | 94,180 |
| 2015 | 3 | 232 | 5 | 26,742 |
| 2016 | 3 | 301 | 7 (1) | 16,560 |
| 2017 | 3 | 305 | 13 | 12,060 |
| 2018 | 3 | 267 | 1 | 16,591 |
| 2019 | 2 | — | 18 (1) | 15,850 |
| 2020 | 1 | — | 16 (5) | 94,186 |
| 2021 | 2 | — | 3 (2) | 199,342 |
| 2022 | 6 | 268 | 2 | 888,020 |
| 2023 | 7 | 265 | 16 (10) | 165,838 |
| 2024 | 5 | 103 | 9 (4) | 57,730 |
| 2025 | 8 | 172 | 7 (4) | 52,792 |
| 2026 | 2 | — | 11 (2) | — |
What is it indicated for?
The ambIT® "PreSet" Ambulatory Infusion Pump is intended for use by surgeons and anesthesiologists for the perioperative and post operative infusion of local anesthetics and narcotics for pain management and regional anesthesia.
Routes of administration include intravenous, subcutaneous, intramuscular, perineural and epidural.
The ambIT® "PreSet" Ambulatory Infusion Pump is also intended to significantly decrease narcotic use and pain when used to deliver local anesthetics to surgical wound sites or close proximity to nerves when compared with narcotic only pain management.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K052221 · printed Nov 6, 2026
Cite this page
510(k) Report. “K052221: Ambit Push & Play Ambulatory Infusion Pump.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K052221
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026