Spacelabs Medical, Inc. · CBR Analyzer, Gas, Nitrous-Oxide, Gaseous Phase (Anesthetic Conc.)

Cleared on Apr 19, 2006 as substantially equivalent to K954962 (Spacelabs, Inc., 1996) and 1 other predicate after a 117-day review. Its family tree reaches back 2 generations to 2000. 3 later devices descend from it. It has been recalled 2 times.

Decided
Apr 19, 2006
Review
117 days
Class
Class II
Product code
CBR
Recalls
2
Predicates
2

Its longest line of descent runs back 2 generations to K001814 (2000). 3 ancestors in all, the oldest K954962 (1996). 3 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1996: 1 other ancestor2011: 1 descendant cleared2012: 1 descendant cleared2013: 1 descendant clearedK001814 · Datex-Ohmeda Compact Airway Module M-Caiovx and M-Covx (Version 01) and Accessories · Datex-Ohmeda · 2000K051092 · Datex-Ohmeda S/5 Compact Airway Module (Model Family E-Caiovx) E-Caiovx, E-Caiov, E-Caio, E-Covx, E-Cov, E-CO & Accesacc · GE Healthcare · 2005 · recalled1995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 1 descendant2 generations forward: 1 descendant3 generations forward: 1 descendant K051092 · Datex-Ohmeda S/5 Compact Airway Module (Model Family E-Caiovx) E-Caiovx, E-Caiov, E-Caio, E-Covx, E-Cov, E-CO & Accesacc · GE Healthcare · 2005 · recalledK001814 · Datex-Ohmeda Compact Airway Module M-Caiovx and M-Covx (Version 01) and Accessories · Datex-Ohmeda · 20000
  1. Root · 2 generations backK001814 Datex-Ohmeda Compact Airway Module M-Caiovx and M-Covx (Version 01)…Datex-Ohmeda · 2000
  2. 1 generation backK051092 Datex-Ohmeda S/5 Compact Airway Module (Model Family E-Caiovx)…GE Healthcare · 2005 · Recalled
  3. This deviceK053599 Spacelabs Medical Multigas Analyzer Module 91518 and AccessoriesSpacelabs Medical, Inc. · 2006
  4. Descendant · cites it directly · 2 of its ownK112173 Speacelabs Multigas ModuleSpacelabs Healthcare · 2011 · Recalled
  5. Descendant · 2 generations on · 1 of its ownK121017 Capnography Pad (92516)Spacelabs Healthcare · 2012
  6. Descendant · 3 generations on · 0 of its ownK130112 Capno Module, 92517Spacelabs Healthcare · 2013

Most influential descendants

Showing 3 of 3 · See all
  • K112173Speacelabs Multigas ModuleSpacelabs Healthcare · 2011 · cites it directly2descendants
  • K121017Capnography Pad (92516)Spacelabs Healthcare · 2012 · 2 generations on1descendant
  • K130112Capno Module, 92517Spacelabs Healthcare · 2013 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K001814Datex-Ohmeda Compact Airway Module M-Caiovx and M-Covx (Version 01) and…Datex-Ohmeda2000—
−1K051092Datex-Ohmeda S/5 Compact Airway Module (Model Family E-Caiovx) E-Caiovx…GE Healthcare20052
0 (this device)K053599Spacelabs Medical Multigas Analyzer Module 91518 and AccessoriesSpacelabs Medical, Inc.2006—
+1K112173Speacelabs Multigas ModuleSpacelabs Healthcare20111
+2K121017Capnography Pad (92516)Spacelabs Healthcare2012—
+3K130112Capno Module, 92517Spacelabs Healthcare2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201210
201310
FIG. 1 — Lineage of K053599, 2000–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CBR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K954962Spacelabs Medical Multigas Analyzer
Summary page 2
…le 91518 is substaatially equivalent in design concepts, technologies Discussion: and materials to the combination of the Spacelabs Medical Module 90518 (K954962) and the Datc-Ohmeda Compact Airway Module E-CAiOVX (K051092). The Module 915;18 was validated through rigorous tes…
Spacelabs, Inc.1996—
*K051092Datex-Ohmeda S/5 Compact Airway Module (Model Family E-Caiovx) E-Caiovx, E-Caiov…
Summary page 2
…ssion: and materials to the combination of the Spacelabs Medical Module 90518 (K954962) and the Datc-Ohmeda Compact Airway Module E-CAiOVX (K051092). The Module 915;18 was validated through rigorous testing that, in part, support the compliance of the Module 9151…
GE Healthcare20052

Also cleared against K954962: 1 other device →

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K112173Speacelabs Multigas ModuleSpacelabs Healthcare20112

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 8, 2011Not classifiedZ-2902-2011Software designSpacelabs received a report of the Model 91518 Multigas Analyzer trending low levels of an anesthetic agent that is not present during a particular case. The error is limited to only the trend table data.
Oct 8, 2007Not classifiedZ-0660-2008Software designInaccurate partial pressure readings; readings are not compensated for ambient pressure in mmHg or kPa.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 6 years and passes through 3 companies; a new generation was cleared every 4.8 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • Of its descendants, K112173 (Spacelabs Healthcare, 2011) has gone furthest, with 2 descendants of its own.
  • 1 other device also cites its predicate K954962.

How does its category compare?

All CBR devices

CBR Analyzer, Gas, Nitrous-Oxide, Gaseous Phase (Anesthetic Conc.): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CBR

1in 2011

2011: 1
2007high 1 (2011) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CBR

Too few CBR 510(k)s in any year since 2007 to give a median.

Recalls per year · CBR

1in 2011

2007: 12011: 1
2007high 1 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · CBR

1in 2025

2008: 12009: 12010: 12011: 12012: 82013: 12015: 12020: 12025: 1
2007high 8 (2012) · low 0 (2007)2025

MAUDE reports naming product code CBR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—10
20080—01
20090—01
20100—01
20111—11
20120—08
20130—01
20140—00
20150—01
20160—00
20170—00
20180—00
20190—00
20200—01
20210—00
20220—00
20230—00
20240—00
20250—01
20260—0—

What is it indicated for?

The Spacelabs Medical Multigas Analyzer Module 91518 (Module 91518) is intended to provide a means of monitoring a variety of gas concentrations and to alert clinical personnel when the concentration of anesthetic agent, oxygen, carbon dioxide or nitrous oxide falls outside of user defined limits. The Module 91518 is capable of automatically identifying which anesthetic agent(s) is being administered. The Module 91518 is intended to be used with, and is…

Read the full statement (125 words)

The Spacelabs Medical Multigas Analyzer Module 91518 (Module 91518) is intended to provide a means of monitoring a variety of gas concentrations and to alert clinical personnel when the concentration of anesthetic agent, oxygen, carbon dioxide or nitrous oxide falls outside of user defined limits. The Module 91518 is capable of automatically identifying which anesthetic agent(s) is being administered.

The Module 91518 is intended to be used with, and is controlled by, any Spacelabs Medical monitor, except the SLP100.

The Module 91518 is intended for use monitoring all hospitalized patients under the direction of qualified medical personnel.

Although the Module 91518 alarms when the duration between breaths exceeds user defined limits, it is not intended to be a primary diagnostic apnea monitor and/or recording device.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K053599: Spacelabs Medical Multigas Analyzer Module 91518 and Accessories.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K053599

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026