510(k) · Cleared
Recalled · Class II · 2014Codman Eds 3 CSF External Drainage System, Models 82-1730, 82-1731, 82-1732, 82-1733, 82-1735, 82-1738
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Codman & Shurtleff, Inc. · JXG Shunt, Central Nervous System And Components
Cleared on Sep 29, 2006 as substantially equivalent to K902257 (Codman & Shurtleff, Inc., 1990) and 2 other predicates after a 115-day review. Its family tree reaches back 1 generation to 1990. 4 later devices descend from it. It has been recalled 3 times.
- Decided
- Sep 29, 2006
- Review
- 115 days
- Class
- Class II
- Product code
- JXG
- Recalls
- 3
- Predicates
- 3
Its longest line of descent runs back 1 generation to K902257 (1990). 3 ancestors in all. 4 later devices descend from it, 2 citing it directly.
- Root · 1 generation backK902257 Codman* External Drainage System II (Eds-II)Codman & Shurtleff, Inc. · 1990
- This deviceK061568 Codman Eds 3 CSF External Drainage System, Models 82-1730, 82-1731…Codman & Shurtleff, Inc. · 2006
- Descendant · cites it directly · 1 of its ownK162437 Codman EDS3 CSF External Drainage SystemCodman & Shurtleff, Inc. · 2016 · Recalled
- Descendant · cites it directly · 1 of its ownK121248 Liquoguard CSF Liquoguard CSF Tubing Set (1500MM) Liquoguard CSF…Moller Medical GmbH · 2013
- Descendant · 2 generations on · 0 of its ownK172537 Codman EDS 3 CSF External Drainage System, Codman EDS 3 CSF External…Codman & Shurtleff, Inc. · 2017
- Descendant · 2 generations on · 0 of its ownK150898 LiquoGuard 7, LiquoGuard 7 Drainage Set, Lenght 2000mmMoller Medical GmbH · 2015
Most influential descendants
Showing 4 of 4 · See all- K162437Codman EDS3 CSF External Drainage SystemCodman & Shurtleff, Inc. · 2016 · cites it directly1descendant
- K121248Liquoguard CSF Liquoguard CSF Tubing Set (1500MM) Liquoguard CSF Tubing Set (2000MM)…Moller Medical GmbH · 2013 · cites it directly1descendant
- K172537Codman EDS 3 CSF External Drainage System, Codman EDS 3 CSF External Drainage System…Codman & Shurtleff, Inc. · 2017 · 2 generations on0descendants
- K150898LiquoGuard 7, LiquoGuard 7 Drainage Set, Lenght 2000mmMoller Medical GmbH · 2015 · 2 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K902257 | Codman* External Drainage System II (Eds-II) | Codman & Shurtleff, Inc. | 1990 | — |
| 0 (this device) | K061568 | Codman Eds 3 CSF External Drainage System, Models 82-1730, 82-1731, 82-1732… | Codman & Shurtleff, Inc. | 2006 | — |
| +1 | K162437 | Codman EDS3 CSF External Drainage System | Codman & Shurtleff, Inc. | 2016 | 3 |
| +1 | K121248 | Liquoguard CSF Liquoguard CSF Tubing Set (1500MM) Liquoguard CSF Tubing Set… | Moller Medical GmbH | 2013 | — |
| +2 | K172537 | Codman EDS 3 CSF External Drainage System, Codman EDS 3 CSF External Drainage… | Codman & Shurtleff, Inc. | 2017 | — |
| +2 | K150898 | LiquoGuard 7, LiquoGuard 7 Drainage Set, Lenght 2000mm | Moller Medical GmbH | 2015 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1991 | 1 | 0 |
| 1995 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2013 | 1 | 0 |
| 2015 | 1 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JXG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JXG device
- #1 K243531 Codman Libertís Shunt Catheter with Bactiseal…score 11.9 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K902257 | Codman* External Drainage System II (Eds-II)Summary page 1…Common Name: External CSF Drainage System Classification Name: Central nervous system fluid shunt and components Predicate Device: K902257 External Drainage System 11 K910938 External Drainage System 1I K9540… | 1990 |
| * | K910938 | Codman External Drainage System II (Eds II)Summary page 1…ication Name: Central nervous system fluid shunt and components Predicate Device: K902257 External Drainage System 11 K910938 External Drainage System 1I K954021 External Drainage System 1I Device Description: The EDS 3 syst… | 1991 |
| * | K954021 | External Drainage System (Eds and Eds II)Summary page 1…onents Predicate Device: K902257 External Drainage System 11 K910938 External Drainage System 1I K954021 External Drainage System 1I Device Description: The EDS 3 system is designed to collect cerebral spinal fluid (CSF) and other… | 1995 |
What descends from it? (4)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Sep 15, 2014 | Class II | Z-0089-2015 | Device Design | tubing within the system that drains CSF may leak or disconnect from the joints and may result in over- or under-drainage of CSF from the ventricular system or introduction of air into the ventricular system (pneumocephalus) |
| Sep 15, 2014 | Class II | Z-0090-2015 | Device Design | tubing within the system that drains CSF may leak or disconnect from the joints and may result in over- or under-drainage of CSF from the ventricular system or introduction of air into the ventricular system (pneumocephalus) |
| Sep 15, 2014 | Class II | Z-0091-2015 | Device Design | tubing within the system that drains CSF may leak or disconnect from the joints and may result in over- or under-drainage of CSF from the ventricular system or introduction of air into the ventricular system (pneumocephalus) |
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All JXG devicesJXG Shunt, Central Nervous System And Components: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JXG
8in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JXG
255in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JXG
3in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JXG
1,198in 2025
MAUDE reports naming product code JXG, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 184 | 0 | 649 |
| 2008 | 6 | 60 | 1 | 630 |
| 2009 | 5 | 106 | 30 | 629 |
| 2010 | 3 | 30 | 0 | 812 |
| 2011 | 7 | 136 | 5 | 787 |
| 2012 | 3 | 78 | 1 | 977 |
| 2013 | 3 | 108 | 14 | 1,004 |
| 2014 | 0 | — | 6 | 1,251 |
| 2015 | 6 | 276 | 0 | 984 |
| 2016 | 6 | 143 | 0 | 1,091 |
| 2017 | 7 | 90 | 1 | 1,335 |
| 2018 | 6 | 102 | 0 | 1,484 |
| 2019 | 4 | 101 | 0 | 1,295 |
| 2020 | 2 | — | 8 | 1,206 |
| 2021 | 1 | — | 0 | 1,467 |
| 2022 | 4 | 101 | 0 | 1,329 |
| 2023 | 5 | 134 | 2 | 1,221 |
| 2024 | 3 | 90 | 3 | 1,214 |
| 2025 | 8 | 255 | 0 | 1,198 |
| 2026 | 2 | — | 1 | — |
What is it indicated for?
Use of the CODMAN EDS 3 CSF External Drainage System is indicated for draining cerebrospinal fluid (CSF) and other fluids of similar physical characteristics as a means of reducing intracranial pressure and CSF volume when the insertion of a permanent, internal shunt is not indicated.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K061568 · printed Nov 6, 2026
Cite this page
510(k) Report. “K061568: Codman Eds 3 CSF External Drainage System, Models 82-1730, 82-1731, 82-1732, 82-1733, 82-1735, 82-1738.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K061568
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026