Pulsera

K061685510(k) TraditionalCleared Sep 15, 200692-day reviewClass II21 CFR 892.1720

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Philips Medical Systems North America Co. · IZL System, X-Ray, Mobile

Cleared on Sep 15, 2006 as substantially equivalent to K042646 (Siemens Medical Systems, Inc., 2004) after a 92-day review. Its family tree reaches back 1 generation to 2004. 15 later devices descend from it.

Decided
Sep 15, 2006
Review
92 days
Class
Class II
Product code
IZL
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K042646 (2004). 15 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2009: 1 descendant cleared2012: 1 descendant cleared2014: 2 descendants cleared2018: 1 descendant cleared2025: 3 descendants cleared2023: 1 descendant cleared2022: 1 descendant cleared2021: 1 descendant cleared2026: 2 descendants cleared2024: 2 descendants clearedK042646 · Dynact · Siemens Medical Systems, Inc. · 2004200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 2 descendants3 generations forward: 1 descendant4 generations forward: 3 descendants5 generations forward: 4 descendants6 generations forward: 3 descendants7 generations forward: 1 descendant K042646 · Dynact · Siemens Medical Systems, Inc. · 20040+5
  1. Root · 1 generation backK042646 DynactSiemens Medical Systems, Inc. · 2004
  2. This deviceK061685 PulseraPhilips Medical Systems North America Co. · 2006
  3. Descendant · cites it directly · 14 of its ownK090590 Veradius, Model 718-130Philips Medical Systems North America Co. · 2009
  4. Descendant · 2 generations on · 12 of its ownK133819 VeradiusPhilips Medical Systems Nederland B.V. · 2014
  5. Descendant · 3 generations on · 11 of its ownK142708 Veradius UnityPhilips Medical Systems Nethrlands BV · 2014 · Recalled
  6. Descendant · 4 generations on · 6 of its ownK183040 Zenition 70Philips Medical Systems Nederland B.V. · 2018 · Recalled
  7. Descendant · 4 generations on · 3 of its ownK230871 Extron 5; Extron 7DRTECH Corporation · 2023

Showing 5 of 15 descendants. See all descendants

Descendants cleared per year

2009: 12012: 12014: 22018: 12021: 12022: 12023: 12024: 22025: 32026: 2
2009high 3 (2025) · low 0 (2010)2026

Most influential descendants

Showing 5 of 15 · See all
  • K090590Veradius, Model 718-130Philips Medical Systems North America Co. · 2009 · cites it directly14descendants
  • K133819VeradiusPhilips Medical Systems Nederland B.V. · 2014 · 2 generations on12descendants
  • K142708Veradius UnityPhilips Medical Systems Nethrlands BV · 2014 · 3 generations on11descendants
  • K183040Zenition 70Philips Medical Systems Nederland B.V. · 2018 · 4 generations on6descendants
  • K230871Extron 5; Extron 7DRTECH Corporation · 2023 · 4 generations on3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K042646DynactSiemens Medical Systems, Inc.2004—
0 (this device)K061685PulseraPhilips Medical Systems North America Co.2006—
+1K090590Veradius, Model 718-130Philips Medical Systems North America Co.2009—
+2K133819VeradiusPhilips Medical Systems Nederland B.V.2014—
+3K142708Veradius UnityPhilips Medical Systems Nethrlands BV20144
+4K183040Zenition 70Philips Medical Systems Nederland B.V.20185
+4K230871Extron 5; Extron 7DRTECH Corporation2023—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201210
201420
201810
202110
202210
202310
202420
202530
202620
FIG. 1 — Lineage of K061685, 2004–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IZL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IZL device

  1. #1 K242015 TOPAZ Mobile X-ray System (Models : TOPAZ-32D…score 19.9 · 19 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K042646Dynact
Summary page 1
…5684 PC Best, The Nederlands Predicate Device: The Philips 3D-RX Option for BV Pulsera is substantially equivalent to the Siemens ArcadisOrbic 3D (FDA Number K042646). Device Description: The Philips 3D-RX Option for BV Pulsera is a mobile C-Armn X-Ray System offering Radiographic and Fluorosc…
Siemens Medical Systems, Inc.2004—

Also cleared against K042646: 3 other devices →

What descends from it? (15)

See all 15

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K090590Veradius, Model 718-130Philips Medical Systems North America Co.200914

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K090590 (Philips Medical Systems North America Co., 2009) has gone furthest, with 14 descendants of its own.
  • 3 other devices also cite its predicate K042646.

How does its category compare?

All IZL devices

IZL System, X-Ray, Mobile: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · IZL

11in 2025

2007: 32008: 42009: 32010: 32011: 62012: 32014: 72015: 42016: 62017: 72018: 82019: 92020: 92021: 132022: 162023: 32024: 92025: 112026 (partial year): 6
2007high 16 (2022) · low 0 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IZL

153in 2025

2007: 30 days median2008: 49 days median2009: 125 days median2010: 65 days median2011: 66 days median2012: 83 days median2014: 104 days median2015: 88 days median2016: 47 days median2017: 45 days median2018: 47 days median2019: 33 days median2020: 43 days median2021: 48 days median2022: 89 days median2023: 55 days median2024: 159 days median2025: 153 days median2026 (partial year): 157 days median
2007high 159 (2024) · low 30 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IZL

47in 2025

2007: 72010: 42011: 62012: 52013: 102014: 42015: 42019: 22020: 12022: 12023: 62024: 52025: 472026 (partial year): 5
2007high 47 (2025) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IZL

27in 2025

2007: 162008: 272009: 352010: 752011: 1182012: 242013: 172014: 512015: 302016: 332017: 352018: 272019: 402020: 482021: 472022: 322023: 772024: 392025: 27
2007high 118 (2011) · low 16 (2007)2025

MAUDE reports naming product code IZL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007330716
2008449027
20093125035
2010365475
20116666118
2012383524
20130—1017
20147104451
2015488430
2016647033
2017745035
2018847027
2019933240
2020943148
20211348047
20221689132
2023355677
20249159539
2025111534727
202661575—

What is it indicated for?

The 3D-RX Option on the BV Pulsera provides 3D imaging functionality and is intended to be used whenever the physician benefits from intra-operatively-generated 3D information of high contrast objects and anatomical structures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K061685: Pulsera.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K061685

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026