510(k) · Cleared
Recalled · Class II · 2017Lightspeed 7.1 CT Scanner System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Ge Medical Systems, LLC · JAK System, X-Ray, Tomography, Computed
Cleared on Jul 12, 2006 as substantially equivalent to K040372 (Ge Medical Systems, LLC, 2004) after a 14-day review. Its family tree reaches back 3 generations to 2001. 45 later devices descend from it. It has been recalled once.
- Decided
- Jul 12, 2006
- Review
- 14 days
- Class
- Class II
- Product code
- JAK
- Recalls
- 1
- Predicates
- 1
Its longest line of descent runs back 3 generations to K013561 (2001). 45 later devices descend from it, 3 citing it directly.
- Root · 3 generations backK013561 Lightspeed 4.0 CT Scanner SystemGE Medical Systems · 2001 · Recalled
- 2 generations backK030420 Lightspeed 5.0 Computed Tomography SystemGE Medical Systems · 2003 · Recalled
- 1 generation backK040372 Lightspeed 7.0 CT Scanner SystemGe Medical Systems, LLC · 2004 · Recalled
- This deviceK061817 Lightspeed 7.1 CT Scanner SystemGe Medical Systems, LLC · 2006
- Descendant · cites it directly · 35 of its ownK081105 GE Lightspeed CT750 HD (Lightspeed 8.0)GE Healthcare · 2008 · Recalled
- Descendant · 2 generations on · 28 of its ownK120833 Discovery CT750 HDGe Medical Systems, LLC · 2012 · Recalled
- Descendant · 3 generations on · 21 of its ownK133705 Revolution CTGe Medical Systems, LLC · 2014 · Recalled
- Descendant · 4 generations on · 15 of its ownK163213 Revolution CTGe Medical Systems, LLC · 2016 · Recalled
- Descendant · 2 generations on · 10 of its ownK103489 GE Veo Reconstruction OptionGeneral Electric Co. · 2011
Showing 5 of 45 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 45 · See all- K081105GE Lightspeed CT750 HD (Lightspeed 8.0)GE Healthcare · 2008 · cites it directly35descendants
- K120833Discovery CT750 HDGe Medical Systems, LLC · 2012 · 2 generations on28descendants
- K133705Revolution CTGe Medical Systems, LLC · 2014 · 3 generations on21descendants
- K163213Revolution CTGe Medical Systems, LLC · 2016 · 4 generations on15descendants
- K103489GE Veo Reconstruction OptionGeneral Electric Co. · 2011 · 2 generations on10descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K013561 | Lightspeed 4.0 CT Scanner System | GE Medical Systems | 2001 | 5 |
| −2 | K030420 | Lightspeed 5.0 Computed Tomography System | GE Medical Systems | 2003 | 4 |
| −1 | K040372 | Lightspeed 7.0 CT Scanner System | Ge Medical Systems, LLC | 2004 | 5 |
| 0 (this device) | K061817 | Lightspeed 7.1 CT Scanner System | Ge Medical Systems, LLC | 2006 | — |
| +1 | K081105 | GE Lightspeed CT750 HD (Lightspeed 8.0) | GE Healthcare | 2008 | 5 |
| +2 | K120833 | Discovery CT750 HD | Ge Medical Systems, LLC | 2012 | 1 |
| +3 | K133705 | Revolution CT | Ge Medical Systems, LLC | 2014 | 14 |
| +4 | K163213 | Revolution CT | Ge Medical Systems, LLC | 2016 | 16 |
| +2 | K103489 | GE Veo Reconstruction Option | General Electric Co. | 2011 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2008 | 3 | 0 |
| 2009 | 1 | 0 |
| 2010 | 1 | 0 |
| 2011 | 3 | 0 |
| 2012 | 3 | 0 |
| 2013 | 1 | 0 |
| 2014 | 3 | 0 |
| 2016 | 3 | 0 |
| 2018 | 2 | 0 |
| 2019 | 4 | 0 |
| 2020 | 3 | 0 |
| 2021 | 2 | 0 |
| 2022 | 4 | 0 |
| 2023 | 3 | 0 |
| 2024 | 3 | 0 |
| 2025 | 3 | 0 |
| 2026 | 3 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JAK device
- #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K040372 | Lightspeed 7.0 CT Scanner SystemSummary page 2…tion software, associated accessories and connections/interfaces to accessories. The LightSpeed 7.1 Scanner System is an evolutionary modification to LightSpeed 7.0 (K040372). It is developed from the hardware platform of LightSpeed 7.0 32/64 slice system by adding new application features that… | 2004 |
What descends from it? (45)
See all 453 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| May 19, 2017 | Class II | Z-2183-2017 | Software design | It was discovered that an issue has been identified that can result in a scan starting before the prescribed delay has completed. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 5 years and passes through 2 companies; a new generation was cleared every 1.3 years on median.
- 3 of the 3 ancestors have a recall of any class.
- Of its descendants, K081105 (GE Healthcare, 2008) has gone furthest, with 35 descendants of its own.
- 3 other devices also cite its predicate K040372.
How does its category compare?
All JAK devicesJAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JAK
27in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JAK
141in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JAK
17in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JAK
219in 2025
MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 14 | 27 | 11 | 76 |
| 2008 | 26 | 42 | 16 | 120 |
| 2009 | 15 | 31 | 29 | 105 |
| 2010 | 7 | 92 | 51 | 119 |
| 2011 | 16 | 155 | 34 | 205 |
| 2012 | 28 | 121 | 23 | 192 |
| 2013 | 17 | 132 | 11 | 414 |
| 2014 | 30 | 200 | 10 | 308 |
| 2015 | 30 | 140 | 28 | 454 |
| 2016 | 25 | 129 | 44 | 365 |
| 2017 | 29 | 96 | 33 | 338 |
| 2018 | 24 | 114 | 10 | 543 |
| 2019 | 28 | 94 | 5 | 233 |
| 2020 | 30 | 112 | 8 | 177 |
| 2021 | 20 | 145 | 15 | 261 |
| 2022 | 30 | 131 | 9 | 199 |
| 2023 | 27 | 139 | 9 | 310 |
| 2024 | 26 | 141 | 20 | 212 |
| 2025 | 27 | 141 | 17 | 219 |
| 2026 | 21 | 167 | 23 | — |
What is it indicated for?
The LightSpeed 7.1 CT Scanner System is indicated for head and whole body X-ray Computed Tomography applications.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K061817 · printed Nov 6, 2026
Cite this page
510(k) Report. “K061817: Lightspeed 7.1 CT Scanner System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K061817
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026