510(k) · Cleared
Recalled · Class II · 2016Aff (Mark I) Volumetric Infusion Pump
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Definitive Medical Technologies, Ltd. · FRN Pump, Infusion
Cleared on May 8, 2007 as substantially equivalent to K003029 (B.Braun Medical, Inc., 2000) and 2 other predicates after a 74-day review. Its family tree reaches back 1 generation to 1992. It has been recalled 5 times.
- Decided
- May 8, 2007
- Review
- 74 days
- Class
- Class II
- Product code
- FRN
- Recalls
- 5
- Predicates
- 3
Its longest line of descent runs back 1 generation to K915522 (1992). 3 ancestors in all. No later device cites it as a predicate yet.
- Root · 1 generation backK915522 Flo-Gard (R) 6201Baxter Healthcare Corp · 1992 · Recalled
- This deviceK070529 Aff (Mark I) Volumetric Infusion PumpDefinitive Medical Technologies, Ltd. · 2007
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K915522 | Flo-Gard (R) 6201 | Baxter Healthcare Corp | 1992 | 6 |
| 0 (this device) | K070529 | Aff (Mark I) Volumetric Infusion Pump | Definitive Medical Technologies, Ltd. | 2007 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1995 | 1 | 0 |
| 2000 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FRN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FRN device
- #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K003029 | Infusomat PSummary page 1…R 880.5725- Trade-name of device: AFF (MARK I) Volumetric Infusion Pump 3. Predicate Devices: B. Braun Infusomatic Infusion Pump (K003029) Sigma International 8000 Infusion Pump (K950766) Baxter Flo-Gard Inf… | 2000 |
| * | K950766 | Sigma 8000 and Sigma 8002Summary page 1…Infusion Pump 3. Predicate Devices: B. Braun Infusomatic Infusion Pump (K003029) Sigma International 8000 Infusion Pump (K950766) Baxter Flo-Gard Infusion Pump (K915522) 4. Description: The Definitive Medical Tech… | 1995 |
| * | K915522 | Flo-Gard (R) 6201Summary page 1…matic Infusion Pump (K003029) Sigma International 8000 Infusion Pump (K950766) Baxter Flo-Gard Infusion Pump (K915522) 4. Description: The Definitive Medical Technologies AFF (Mark I) Volumetric Infusion Pump… | 1992 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Jun 14, 2016 | Class II | Z-2220-2016 | Device Design | WalkMed Infusion, LLC Announces a Voluntary Field Action of the Triton Infusion Pump (model 300000) and Triton FP Infusion Pump (model 400000) Due to Unapproved Changes to the Software and Specifications of the Triton Infusion Pump (model… |
| Jun 14, 2016 | Class II | Z-2219-2016 | Device Design | WalkMed Infusion, LLC Announces a Voluntary Field Action of the Triton Infusion Pump (model 300000) and Triton FP Infusion Pump (model 400000) Due to Unapproved Changes to the Software and Specifications of the Triton Infusion Pump (model… |
| Oct 1, 2015 | Class II | Z-0242-2016 | Device Design | The device might fail to detect air in line while infusing the medication Venofer. This may occur when a drop of Venofer gets stuck in the tubing adjacent to the bubble detector and the Total Volume Limit is programmed higher than the… |
| Feb 17, 2014 | Class II | Z-1122-2014 | Labeling design | WalkMed Infusion is initiaing a recall on their Triton FP Infusion Pump, Part Number 400000 due to the label on the right side of the pump containing an incorrect instruction. |
| Jun 17, 2010 | Not classified | Z-0307-2011 | Device Design | Pump door may be in a near shut position, but unlatched, and the "Door Open" alarm may not sound. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- 1 of the 3 ancestors has a recall of any class.
- 1 other device also cites its predicate K003029.
How does its category compare?
All FRN devicesFRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.
FDA decisions per year · FRN
8in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FRN
172in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FRN
7in 2025
Class I (37 since 2007) Class II/III not classified
Adverse event reports per year · FRN
52,792in 2025
MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 12 | 102 | 15 | 1,086 |
| 2008 | 8 | 89 | 24 | 8,261 |
| 2009 | 9 | 66 | 102 | 1,952 |
| 2010 | 3 | 93 | 37 | 6,133 |
| 2011 | 3 | 103 | 69 | 41,367 |
| 2012 | 4 | 217 | 42 (2) | 15,482 |
| 2013 | 6 | 312 | 22 (3) | 40,082 |
| 2014 | 6 | 172 | 4 (3) | 94,180 |
| 2015 | 3 | 232 | 5 | 26,742 |
| 2016 | 3 | 301 | 7 (1) | 16,560 |
| 2017 | 3 | 305 | 13 | 12,060 |
| 2018 | 3 | 267 | 1 | 16,591 |
| 2019 | 2 | — | 18 (1) | 15,850 |
| 2020 | 1 | — | 16 (5) | 94,186 |
| 2021 | 2 | — | 3 (2) | 199,342 |
| 2022 | 6 | 268 | 2 | 888,020 |
| 2023 | 7 | 265 | 16 (10) | 165,838 |
| 2024 | 5 | 103 | 9 (4) | 57,730 |
| 2025 | 8 | 172 | 7 (4) | 52,792 |
| 2026 | 2 | — | 11 (2) | — |
What is it indicated for?
The AFF (MARK I) Volumetric Infusion Pump is indicated for delivering infusions of medications, as well as providing TPN (Total Parenteral Nutrition) and PCA (Patient Control Analgesia). It is intended for use in hospitals, ambulatory & nursing home (extended care) settings, and home care environments.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K070529 · printed Nov 6, 2026
Cite this page
510(k) Report. “K070529: Aff (Mark I) Volumetric Infusion Pump.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K070529
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026