510(k) Report

510(k) · Cleared

Recalled · Class II · 2023

Centricity Pacs IW

K082318510(k) SpecialCleared Aug 25, 200812-day reviewClass II21 CFR 892.2050Recalls 7

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ge Healthcare Dynamic Imaging Solutions · LLZ System, Image Processing, Radiological

Cleared on Aug 25, 2008 as substantially equivalent to K031311 (Dynamic Imaging, Inc., 2003) and 3 other predicates after a 12-day review. Its family tree reaches back 4 generations to 1994. 18 later devices descend from it. It has been recalled 7 times.

Decided
Aug 25, 2008
Review
12 days
Class
Class II
Product code
LLZ
Recalls
7
Predicates
4

Its longest line of descent runs back 4 generations to K942120 (1994). 11 ancestors in all. 18 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2007: 1 other ancestor2005: 1 other ancestor2004: 1 other ancestor2003: 2 other ancestors2000: 1 other ancestor1996: 1 other ancestor2010: 1 descendant cleared2012: 2 descendants cleared2015: 2 descendants cleared2016: 3 descendants cleared2013: 1 descendant cleared2024: 2 descendants cleared2014: 1 descendant cleared2018: 1 descendant cleared2022: 1 descendant cleared2021: 1 descendant cleared2026: 2 descendants cleared2025: 1 descendant clearedK942120 · Advantage Windows Diagnostic X-Ray Workstation · GE Medical Systems · 1994K013630 · Isite Radiology · Stentor, Inc. · 2001K031311 · Integradweb by Dynamic Imaging, Inc. · Dynamic Imaging, Inc. · 2003K042313 · Integradweb MPR/Mip · Dynamic Imaging, Inc. · 20041990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 2 other ancestors3 generations back: 3 other ancestors 1 generation forward: 2 descendants2 generations forward: 1 descendant3 generations forward: 6 descendants4 generations forward: 2 descendants5 generations forward: 3 descendants6 generations forward: 4 descendants K042313 · Integradweb MPR/Mip · Dynamic Imaging, Inc. · 2004K031311 · Integradweb by Dynamic Imaging, Inc. · Dynamic Imaging, Inc. · 2003K013630 · Isite Radiology · Stentor, Inc. · 2001K942120 · Advantage Windows Diagnostic X-Ray Workstation · GE Medical Systems · 19940+5
  1. Root · 4 generations backK942120 Advantage Windows Diagnostic X-Ray WorkstationGE Medical Systems · 1994
  2. 3 generations backK013630 Isite RadiologyStentor, Inc. · 2001
  3. 2 generations backK031311 Integradweb by Dynamic Imaging, Inc.Dynamic Imaging, Inc. · 2003
  4. 1 generation backK042313 Integradweb MPR/MipDynamic Imaging, Inc. · 2004
  5. This deviceK082318 Centricity Pacs IWGe Healthcare Dynamic Imaging Solutions · 2008
  6. Descendant · cites it directly · 16 of its ownK121387 Centricity Pacs-IWGe Healthcare Integrated IT Solutions · 2012 · Recalled
  7. Descendant · 2 generations on · 15 of its ownK123174 Centricity Pacs-IW with Universal ViewerGE Healthcare · 2012 · Recalled
  8. Descendant · 3 generations on · 6 of its ownK131977 Centricity Universal Viewer Zero Footprint ClientGE Healthcare · 2013 · Recalled
  9. Descendant · 4 generations on · 5 of its ownK141881 RapidresultsRamsoft, Inc. · 2014
  10. Descendant · 5 generations on · 3 of its ownK222476 OmegaAI Image ViewerRamsoft, Inc. · 2022

Showing 5 of 18 descendants. See all descendants

Descendants cleared per year

2010: 12012: 22013: 12014: 12015: 22016: 32018: 12021: 12022: 12024: 22025: 12026: 2
2010high 3 (2016) · low 0 (2011)2026

Most influential descendants

Showing 5 of 18 · See all
  • K121387Centricity Pacs-IWGe Healthcare Integrated IT Solutions · 2012 · cites it directly16descendants
  • K123174Centricity Pacs-IW with Universal ViewerGE Healthcare · 2012 · 2 generations on15descendants
  • K131977Centricity Universal Viewer Zero Footprint ClientGE Healthcare · 2013 · 3 generations on6descendants
  • K141881RapidresultsRamsoft, Inc. · 2014 · 4 generations on5descendants
  • K222476OmegaAI Image ViewerRamsoft, Inc. · 2022 · 5 generations on3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K942120Advantage Windows Diagnostic X-Ray WorkstationGE Medical Systems1994—
−3K013630Isite RadiologyStentor, Inc.2001—
−2K031311Integradweb by Dynamic Imaging, Inc.Dynamic Imaging, Inc.2003—
−1K042313Integradweb MPR/MipDynamic Imaging, Inc.2004—
0 (this device)K082318Centricity Pacs IWGe Healthcare Dynamic Imaging Solutions2008—
+1K121387Centricity Pacs-IWGe Healthcare Integrated IT Solutions20121
+2K123174Centricity Pacs-IW with Universal ViewerGE Healthcare201210
+3K131977Centricity Universal Viewer Zero Footprint ClientGE Healthcare20138
+4K141881RapidresultsRamsoft, Inc.2014—
+5K222476OmegaAI Image ViewerRamsoft, Inc.2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
200010
200320
200410
200510
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
201220
201310
201410
201520
201630
201810
202110
202210
202420
202510
202620
FIG. 1 — Lineage of K082318, 1994–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K031311Integradweb by Dynamic Imaging, Inc.
Summary page 1
…August 12, 2008 Classification Name: Picture Archiving Communications System Proprietary Name: Centricity PACS IWTMPACS System Predicate Devices: #K031311 IntegradWebTM PACS System by Dynamic Imaging, Inc. #K042313 IntegradWeb TM MRP/MIP TM by Dynamic Imagi…
Dynamic Imaging, Inc.2003—
*K042313Integradweb MPR/Mip
Summary page 1
…rietary Name: Centricity PACS IWTMPACS System Predicate Devices: #K031311 IntegradWebTM PACS System by Dynamic Imaging, Inc. #K042313 IntegradWeb TM MRP/MIP TM by Dynamic Imaging, Inc. #K072986 IntegradWeb TMPACS System by GE Healthcare…
Dynamic Imaging, Inc.2004—
*K072986Integradweb Pacs System
Summary page 1
…311 IntegradWebTM PACS System by Dynamic Imaging, Inc. #K042313 IntegradWeb TM MRP/MIP TM by Dynamic Imaging, Inc. #K072986 IntegradWeb TMPACS System by GE Healthcare Dynamic Imaging Solutions #K051673 Xeleris 2 Processing and…
GE Healthcare2007—
*K051673Xeleris 2 Processing and Review Workstation
Summary page 1
…MRP/MIP TM by Dynamic Imaging, Inc. #K072986 IntegradWeb TMPACS System by GE Healthcare Dynamic Imaging Solutions #K051673 Xeleris 2 Processing and Review Workstation by GE Medical Systems Device Description: Centricity PACS IWTMPACS System isan Intern…
GE Medical Systems20053

Also cleared against K031311: 1 other device →

What descends from it? (18)

See all 18

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K121387Centricity Pacs-IWGe Healthcare Integrated IT Solutions201216
K091631Accessnet, Accessmed, Accessrad, MedviewAspyra, Inc.20100

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 14, 2023Class IIZ-0138-2024Software designGE HealthCare has become aware of an issue where images from two different patients may be contained in a single study, when stored in Centricity PACS-IW V3.7.x, Centricity PACS-IW with Universal Viewer V5.0 and Centricity Universal…
Mar 28, 2023Class IIZ-1502-2023OtherGE HealthCare has become aware of an issue where information from two different patients can be mismatched when correcting patient or study information.
May 22, 2019Class IIZ-1781-2019Software designThere is a potential that one or more image series (i.e., all images within an image set) may be missing from an exam without a warning displayed in the viewer.
Feb 23, 2018Class IIZ-1302-2018Software designA database handling error could occur during the image acquisition process affecting the completeness of acquired images with Centricity PACS-IW. There is a potential that one or more image series (i.e. all images within an image set) may…
Sep 16, 2015Class IIZ-0023-2016Software Design ChangeImages may be missing when a system parameter MapRoute is set to a value greater than 1.
Feb 18, 2010Not classifiedZ-1394-2010Software designThere is a potential safety issue associated with the use of GE Centricity PACS-IW and PACS Web Diagnostic software related to use of built-in reconstruction functions which may result in incorrect anatomic orientation markers.
Feb 11, 2010Not classifiedZ-1402-2010Software design (manufacturing process)There is a potential safety issue associated with the use of GE Centricity PACS-IW and PACS Web Diagnostic software when dragging-and-dropping images from the Navigator causing flipping of the images that may impact patient safety.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 4 companies; a new generation was cleared every 4.0 years on median.
  • 2 of the 11 ancestors have a recall of any class.
  • Of its descendants, K121387 (Ge Healthcare Integrated IT Solutions, 2012) has gone furthest, with 16 descendants of its own.
  • 1 other device also cites its predicate K031311.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

Centricity PACS lW TMby GE Healthcare Dynamic Imaging Solutions is a device that receives medical images (including mammograms) and data from various imaging sources. Images and data can be stored, communicated, processed and displayed within the system or across computer networks at distributed locations. Lossy compressed mammographic images and digitized film screen images must not be reviewed for primary image interpretations. Mammographic images may…

Read the full statement (109 words)

Centricity PACS lW TMby GE Healthcare Dynamic Imaging Solutions is a device that receives medical images (including mammograms) and data from various imaging sources. Images and data can be stored, communicated, processed and displayed within the system or across computer networks at distributed locations.

Lossy compressed mammographic images and digitized film screen images must not be reviewed for primary image interpretations. Mammographic images may only be interpreted using an FDA approved monitor that offers at least 5 Mpixel resolution and meets other technical specifications reviewed and accepted by FDA.

Typical users of this system are trained professionals, including but not limited to physicians, radiologists, nurses, medical technicians, and assistants.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K082318: Centricity Pacs IW.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K082318

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026