510(k) Report

510(k) · Cleared

Cleared

Evite XL

K083050510(k) SpecialCleared Dec 29, 200876-day reviewClass II21 CFR 868.5895

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Draeger Medical AG & Co. KG · CBK Ventilator, Continuous, Facility Use

Cleared on Dec 29, 2008 as substantially equivalent to K010093 (Drager Medizintechnik GmbH, 2001) and 2 other predicates after a 76-day review. Its family tree reaches back 2 generations to 1991. 2 later devices descend from it.

Decided
Dec 29, 2008
Review
76 days
Class
Class II
Product code
CBK
Recalls
None
Predicates
3

Its longest line of descent runs back 2 generations to K902859 (1991). 5 ancestors in all. 2 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2001: 1 other ancestor1998: 1 other ancestor1994: 1 other ancestor2023: 1 descendant cleared2025: 1 descendant clearedK902859 · Servo Ventilator 300 · Siemens Life Support Systems · 1991 · recalledK974176 · Babylog 8000 Plus · Drager, Inc. · 1998 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 1 other ancestor 1 generation forward: 2 descendants K974176 · Babylog 8000 Plus · Drager, Inc. · 1998 · recalledK902859 · Servo Ventilator 300 · Siemens Life Support Systems · 1991 · recalled0
  1. Root · 2 generations backK902859 Servo Ventilator 300Siemens Life Support Systems · 1991 · Recalled
  2. 1 generation backK974176 Babylog 8000 PlusDrager, Inc. · 1998 · Recalled
  3. This deviceK083050 Evite XLDraeger Medical AG & Co. KG · 2008
  4. Descendant · cites it directly · 1 of its ownK220107 Mindray SV600 Ventilator, Mindray SV800 VentilatorShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2023
  5. Descendant · cites it directly · 0 of its ownK243767 SV600, SV800 VentilatorShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2025

Most influential descendants

Showing 2 of 2 · See all
  • K220107Mindray SV600 Ventilator, Mindray SV800 VentilatorShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2023 · cites it directly1descendant
  • K243767SV600, SV800 VentilatorShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K902859Servo Ventilator 300Siemens Life Support Systems19913
−1K974176Babylog 8000 PlusDrager, Inc.19981
0 (this device)K083050Evite XLDraeger Medical AG & Co. KG2008—
+1K220107Mindray SV600 Ventilator, Mindray SV800 VentilatorShenzhen Mindray Bio-Medical Electronics Co., Ltd.2023—
+1K243767SV600, SV800 VentilatorShenzhen Mindray Bio-Medical Electronics Co., Ltd.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199810
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202310
202510
FIG. 1 — Lineage of K083050, 1991–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CBK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CBK device

  1. #1 K252663 Inbentus Versatilescore 16.0 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K010093Non-Invasive Ventilation Niv Option, Model 84 14 474
Summary page 2
…A Dr~ger and Siemens Company Legally Marketed Devices to which Substantial Equivalence is claimed: 510(k) number Trade name Company K 010093; K980642 Evita XL Draeger Medical AG & Co. KG K 974176 Babylog 8000 plus D…
Drager Medizintechnik GmbH20013
*K980642EVITA 4 (8411900)
Summary page 2
…er and Siemens Company Legally Marketed Devices to which Substantial Equivalence is claimed: 510(k) number Trade name Company K 010093; K980642 Evita XL Draeger Medical AG & Co. KG K 974176 Babylog 8000 plus Draeger Me…
Drager, Inc.1998—
*K974176Babylog 8000 Plus
Summary page 2
…ivalence is claimed: 510(k) number Trade name Company K 010093; K980642 Evita XL Draeger Medical AG & Co. KG K 974176 Babylog 8000 plus Draeger Medical AG & Co. KG Device Description: Evita XL is a time-cycled micropr…
Drager, Inc.19981

Also cleared against K010093: 5 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K220107Mindray SV600 Ventilator, Mindray SV800 VentilatorShenzhen Mindray Bio-Medical Electronics Co., Ltd.20231
K243767SV600, SV800 VentilatorShenzhen Mindray Bio-Medical Electronics Co., Ltd.20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 3 companies; a new generation was cleared every 10.5 years on median.
  • 3 of the 5 ancestors have a recall of any class.
  • Of its descendants, K220107 (Shenzhen Mindray Bio-Medical Electronics Co., Ltd., 2023) has gone furthest, with 1 descendant of its own.
  • 5 other devices also cite its predicate K010093.

How does its category compare?

All CBK devices

CBK Ventilator, Continuous, Facility Use: FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · CBK

4in 2025

2007: 112008: 182009: 122010: 142011: 132012: 172013: 52014: 52015: 72016: 42017: 62018: 42019: 82020: 52021: 62023: 52024: 92025: 42026 (partial year): 3
2007high 18 (2008) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CBK

163in 2025

2007: 142 days median2008: 115 days median2009: 122 days median2010: 150 days median2011: 192 days median2012: 207 days median2013: 277 days median2014: 439 days median2015: 266 days median2016: 323 days median2017: 280 days median2018: 183 days median2019: 435 days median2020: 176 days median2021: 267 days median2023: 309 days median2024: 203 days median2025: 163 days median2026 (partial year): 235 days median
2007high 439 (2014) · low 115 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CBK

14in 2024

2007: 172008: 232009: 82010: 92011: 122012: 2, 1 Class I2013: 5, 2 Class I2014: 5, 4 Class I2015: 6, 4 Class I2016: 4, 1 Class I2017: 12018: 3, 3 Class I2019: 14, 13 Class I2020: 42021: 21, 19 Class I2022: 8, 4 Class I2023: 4, 3 Class I2024: 14, 14 Class I2026 (partial year): 15, 13 Class I
2007high 23 (2008) · low 0 (2025)2026

Class I (81 since 2007) Class II/III not classified

Adverse event reports per year · CBK

13,991in 2025

2007: 1,5312008: 1,9332009: 1,7662010: 1,7992011: 1,8772012: 5,5092013: 7,9212014: 7,6002015: 11,8762016: 16,0562017: 14,4512018: 9,8492019: 9,1002020: 11,0962021: 13,3222022: 15,9742023: 24,9282024: 20,3362025: 13,991
2007high 24,928 (2023) · low 1,531 (2007)2025

MAUDE reports naming product code CBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711142171,531
200818115231,933
20091212281,766
20101415091,799
201113192121,877
2012172072 (1)5,509
201352775 (2)7,921
201454395 (4)7,600
201572666 (4)11,876
201643234 (1)16,056
20176280114,451
201841833 (3)9,849
2019843514 (13)9,100
20205176411,096
2021626721 (19)13,322
20220—8 (4)15,974
202353094 (3)24,928
2024920314 (14)20,336
20254163013,991
2026323515 (13)—

What is it indicated for?

Long-term ventilator for intensive care.

For adults, children, and neonates with a minimum body weight of 3 kg (6.6 lbs). For premature infants with a minimum body weight of 0.5 kg (1.1 lbs) with the NeoFlow option.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K083050: Evite XL.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K083050

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026