EVITA 4 (8411900)

K980642510(k) TraditionalCleared Sep 4, 1998197-day reviewClass II21 CFR 868.5895

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Drager, Inc. · CBK Ventilator, Continuous, Facility Use

Cleared on Sep 4, 1998 after a 197-day review. The FDA summary names its predicate without a number. 32 of the 113 devices in its family, counting itself, have a Class I recall. 112 later devices descend from it.

Decided
Sep 4, 1998
Review
197 days
Class
Class II
Product code
CBK
Recalls
None
Predicates
0

112 later devices descend from it, 7 citing it directly. 32 of the 113 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2005: 2 descendants cleared2004: 6 descendants cleared, 2 with a Class I recall22007: 5 descendants cleared2010: 6 descendants cleared, 1 with a Class I recall12008: 10 descendants cleared, 2 with a Class I recall22002: 1 descendant cleared2006: 4 descendants cleared, 1 with a Class I recall12011: 9 descendants cleared, 6 with a Class I recall62009: 5 descendants cleared, 1 with a Class I recall12023: 5 descendants cleared, 1 with a Class I recall12025: 3 descendants cleared2012: 8 descendants cleared, 2 with a Class I recall22014: 3 descendants cleared, 1 with a Class I recall12019: 5 descendants cleared, 1 with a Class I recall12015: 7 descendants cleared, 1 with a Class I recall12026: 4 descendants cleared2024: 4 descendants cleared2021: 6 descendants cleared, 2 with a Class I recall22013: 6 descendants cleared, 3 with a Class I recall32017: 6 descendants cleared, 3 with a Class I recall32016: 2 descendants cleared, 2 with a Class I recall22020: 4 descendants cleared, 3 with a Class I recall32018: 1 descendant cleared1995200020052010201520202025
  1. This deviceK980642 EVITA 4 (8411900)Drager, Inc. · 1998
  2. Descendant · cites it directly · 102 of its ownK022132 Servo Ventilator System, Model 64 87 800 E407ESiemens Medical Solutions USA, Inc. · 2002
  3. Descendant · cites it directly · 75 of its ownK040221 Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB · 2004 · Recalled
  4. Descendant · 2 generations on · 73 of its ownK041223 Modification to Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB · 2004 · Recalled (Class I)
  5. Descendant · 3 generations on · 61 of its ownK063404 Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB · 2007
  6. Descendant · cites it directly · 53 of its ownK040574 Galileo GoldHamilton Medical, Inc. · 2004

Showing 5 of 112 descendants. See all descendants

Descendants cleared per year

2002: 12004: 62005: 22006: 42007: 52008: 102009: 52010: 62011: 92012: 82013: 62014: 32015: 72016: 22017: 62018: 12019: 52020: 42021: 62023: 52024: 42025: 32026: 4
2002high 10 (2008) · low 0 (2003)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 112 · See all
  • K022132Servo Ventilator System, Model 64 87 800 E407ESiemens Medical Solutions USA, Inc. · 2002 · cites it directly102descendants
  • K040221Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB · 2004 · cites it directly75descendants
  • K041223Modification to Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB · 2004 · 2 generations on73descendants
  • K063404Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB · 2007 · 3 generations on61descendants
  • K040574Galileo GoldHamilton Medical, Inc. · 2004 · cites it directly53descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K980642EVITA 4 (8411900)Drager, Inc.1998—
+1K022132Servo Ventilator System, Model 64 87 800 E407ESiemens Medical Solutions USA, Inc.2002—
+1K040221Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB20041
+2K041223Modification to Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB2004Class I
+3K063404Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB2007—
+1K040574Galileo GoldHamilton Medical, Inc.2004—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200210
200462
200520
200641
200750
2008102
200951
201061
201196
201282
201363
201431
201571
201622
201763
201810
201951
202043
202162
202351
202440
202530
202640
FIG. 1 — Lineage of K980642, 1998–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

32 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CBK device

  1. #1 K252663 Inbentus Versatilescore 16.0 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Evita 4
Named without a submission number
—
*—Evita 2 dura
Named without a submission number
—
*—Servo 300
Named without a submission number
—

What descends from it? (112)

See all 112

7 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K022132Servo Ventilator System, Model 64 87 800 E407ESiemens Medical Solutions USA, Inc.2002102
K040221Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB200475
K040574Galileo GoldHamilton Medical, Inc.200453
K051263Evitaxl with Option SmartcareDrager Medical AG & Co. Kgaa200551
K093632Infinity Acute Care System Workstation Neonatal Care Class IDrager Medical AG & Co. Kgaa201010
K072450Esprit Ventilator Auto-Trak Sensitivity Option, Model V1000Respironics California, Inc.20076
K083050Evite XLDraeger Medical AG & Co. KG20082

Has anything in its family been recalled? (32 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K093632Infinity Acute Care System Workstation Neonatal CareDrager Medical AG & Co. Kgaa · 2010 · Cites it directly · ◆ in the 2010 descendants bar of FIG. 14 Class I recalls
  • K034040Esprit Ventilator, Model V1000Respironics, Inc. · 2004 · 2 generations on · ◆ in the 2004 descendants bar of FIG. 11 Class I recall
  • K073069Modification to Avea VentilatorViasys Respiratory Care, Inc. · 2008 · 2 generations on · ◆ in the 2008 descendants bar of FIG. 113 Class I recalls
  • K041223Modification to Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB · 2004 · 2 generations on · ◆ in the 2004 descendants bar of FIG. 11 Class I recall
  • K081521Modification to Hamilton-G5Hamilton Medical AG · 2008 · 2 generations on · ◆ in the 2008 descendants bar of FIG. 11 Class I recall
  • K053388Model 840 Ventilator with Proportional Assist Ventilation Plus Software OptionPuritan Bennett Corp. · 2006 · 2 generations on · ◆ in the 2006 descendants bar of FIG. 11 Class I recall
  • K121225Hamilton-C2Hamilton Medical AG · 2012 · 2 generations on · ◆ in the 2012 descendants bar of FIG. 11 Class I recall
  • K103803Hamilton-G5Hamilton Medical AG · 2011 · 3 generations on · ◆ in the 2011 descendants bar of FIG. 11 Class I recall
  • K111116Engstrom Carestation, Engstrom Pro, Models 1505-9000-000, 1505-9003-000Datex-Ohmeda · 2011 · 4 generations on · ◆ in the 2011 descendants bar of FIG. 13 Class I recalls
  • K112722GE Datex-Ohmeda AvanceDatex-Ohmeda, Inc. · 2011 · 4 generations on · ◆ in the 2011 descendants bar of FIG. 12 Class I recalls
  • K110213GE Datex-Ohmeda AisysDatex-Ohmeda, Inc. · 2011 · 4 generations on · ◆ in the 2011 descendants bar of FIG. 12 Class I recalls
  • K130178Inspiration Ventilator System 5I/7IeVent Medical, Ltd. · 2013 · 4 generations on · ◆ in the 2013 descendants bar of FIG. 11 Class I recall

Nearest 12 of 32 shown.

What does this lineage say?

  • Of its descendants, K022132 (Siemens Medical Solutions USA, Inc., 2002) has gone furthest, with 102 descendants of its own.

How does its category compare?

All CBK devices

CBK Ventilator, Continuous, Facility Use: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CBK

4in 2025

2007: 112008: 182009: 122010: 142011: 132012: 172013: 52014: 52015: 72016: 42017: 62018: 42019: 82020: 52021: 62023: 52024: 92025: 42026 (partial year): 3
2007high 18 (2008) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CBK

163in 2025

2007: 142 days median2008: 115 days median2009: 122 days median2010: 150 days median2011: 192 days median2012: 207 days median2013: 277 days median2014: 439 days median2015: 266 days median2016: 323 days median2017: 280 days median2018: 183 days median2019: 435 days median2020: 176 days median2021: 267 days median2023: 309 days median2024: 203 days median2025: 163 days median2026 (partial year): 235 days median
2007high 439 (2014) · low 115 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CBK

14in 2024

2007: 172008: 232009: 82010: 92011: 122012: 2, 1 Class I2013: 5, 2 Class I2014: 5, 4 Class I2015: 6, 4 Class I2016: 4, 1 Class I2017: 12018: 3, 3 Class I2019: 14, 13 Class I2020: 42021: 21, 19 Class I2022: 8, 4 Class I2023: 4, 3 Class I2024: 14, 14 Class I2026 (partial year): 15, 13 Class I
2007high 23 (2008) · low 0 (2025)2026

Class I (81 since 2007) Class II/III not classified

Adverse event reports per year · CBK

13,991in 2025

2007: 1,5312008: 1,9332009: 1,7662010: 1,7992011: 1,8772012: 5,5092013: 7,9212014: 7,6002015: 11,8762016: 16,0562017: 14,4512018: 9,8492019: 9,1002020: 11,0962021: 13,3222022: 15,9742023: 24,9282024: 20,3362025: 13,991
2007high 24,928 (2023) · low 1,531 (2007)2025

MAUDE reports naming product code CBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711142171,531
200818115231,933
20091212281,766
20101415091,799
201113192121,877
2012172072 (1)5,509
201352775 (2)7,921
201454395 (4)7,600
201572666 (4)11,876
201643234 (1)16,056
20176280114,451
201841833 (3)9,849
2019843514 (13)9,100
20205176411,096
2021626721 (19)13,322
20220—8 (4)15,974
202353094 (3)24,928
2024920314 (14)20,336
20254163013,991
2026323515 (13)—

What is it indicated for?

Evita 4 is a time cycled, constant volume, long term, intensive care ventilator for adults and children with a body weight of at least 3 kg.

Intended Environment for the device:

- hospital use

- inner clinical transportt

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K980642: EVITA 4 (8411900).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K980642

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.