510(k) · Cleared
ClearedZoll E Series with Cprreadycharge
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Zoll Medical Corporation, World Wide Headquarters · MKJ Automated External Defibrillators (Non-Wearable)
Cleared on Dec 23, 2009 as substantially equivalent to K042007 (Zoll Medical Corp, 2005) after a 237-day review. Its family tree reaches back 7 generations to 1997. 1 of the 19 devices in its family, counting itself, has a Class I recall.
- Decided
- Dec 23, 2009
- Review
- 237 days
- Class
- Class III
- Product code
- MKJ
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 7 generations to K962603 (1997). 18 ancestors in all, the oldest K945071 (1995). No later device cites it as a predicate yet. 1 of the 19 devices in this family, counting this one, has a Class I recall.
- Root · 7 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
- 6 generations backK973887 Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and…Masimo Corp. · 1998
- 5 generations backK982255 Model 2000 Pulse OximeterIvy Biomedical Systems, Inc. · 1998
- 4 generations backK991823 N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc. · 1999
- 3 generations backK012451 Propaq Encore Models 202, 204, 206; Propaq CS Models 242, 244, 246Welch Allyn Protocol, Inc. · 2001
- 2 generations backK032363 Zoll M Series Nibp OptionZoll Medical Corp · 2003
- 1 generation backK042007 Zoll E Series DefibrillatorZoll Medical Corp · 2005 · Recalled
- This deviceK091265 Zoll E Series with CprreadychargeZoll Medical Corporation, World Wide Headquarters · 2009
Class I recalls in this family
- K022732 Infant/Child Reduced Energy Electrodes3 generations back · 2002
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −7 | K962603 | Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables | Masimo Corp. | 1997 | — |
| −6 | K973887 | Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables | Masimo Corp. | 1998 | — |
| −5 | K982255 | Model 2000 Pulse Oximeter | Ivy Biomedical Systems, Inc. | 1998 | — |
| −4 | K991823 | N-395 Pulse Oximeter, Model N-395 | Nellcor Puritan Bennett, Inc. | 1999 | — |
| −3 | K012451 | Propaq Encore Models 202, 204, 206; Propaq CS Models 242, 244, 246 | Welch Allyn Protocol, Inc. | 2001 | — |
| −2 | K032363 | Zoll M Series Nibp Option | Zoll Medical Corp | 2003 | — |
| −1 | K042007 | Zoll E Series Defibrillator | Zoll Medical Corp | 2005 | 3 |
| 0 (this device) | K091265 | Zoll E Series with Cprreadycharge | Zoll Medical Corporation, World Wide Headquarters | 2009 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1995 | 1 | 0 |
| 1996 | 2 | 0 |
| 1999 | 4 | 0 |
| 2000 | 1 | 0 |
| 2001 | 1 | 0 |
| 2002 | 1 | 1 |
| 2004 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K042007 | Zoll E Series DefibrillatorSummary page 2…features and functions of the E Series with CPRReadyCharge are based on the same technology as that found in the E Series product, reviewed and cleared by the FDA under K042007. Defibrillator Function The E Series products contain a DC defibrillator capableof delivering up to 200 joules of energy. It m… | 2005 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (1 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K022732Infant/Child Reduced Energy ElectrodesMedtronic Physio-Control Corp. · 2002 · 3 generations back · ◆ in the 2002 ancestors bar of FIG. 12 Class I recalls
What does this lineage say?
- The line of descent spans 12 years and passes through 6 companies; a new generation was cleared every 1.4 years on median.
- 5 of the 18 ancestors have a recall of any class; 1 has a Class I recall.
- 8 other devices also cite its predicate K042007.
How does its category compare?
All MKJ devicesMKJ Automated External Defibrillators (Non-Wearable): FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · MKJ
48in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MKJ
156in 2015
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MKJ
1in 2025
Class I (23 since 2007) Class II/III not classified
Adverse event reports per year · MKJ
13,315in 2025
MAUDE reports naming product code MKJ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 7 | 69 | 12 | 3,958 |
| 2008 | 13 | 141 | 24 | 4,752 |
| 2009 | 8 | 165 | 37 | 6,782 |
| 2010 | 4 | 250 | 35 | 7,399 |
| 2011 | 11 | 36 | 7 | 8,170 |
| 2012 | 10 | 197 | 5 (1) | 9,732 |
| 2013 | 7 | 191 | 4 | 14,955 |
| 2014 | 11 | 196 | 24 (15) | 15,399 |
| 2015 | 6 | 156 | 1 | 16,129 |
| 2016 | 0 | — | 2 (1) | 17,062 |
| 2017 | 4 | — | 6 (4) | 16,684 |
| 2018 | 20 | — | 3 | 16,591 |
| 2019 | 25 | — | 6 (2) | 16,861 |
| 2020 | 52 | — | 2 | 16,197 |
| 2021 | 41 | — | 4 | 16,300 |
| 2022 | 19 | — | 3 | 14,867 |
| 2023 | 24 | — | 11 | 13,766 |
| 2024 | 27 | — | 5 | 15,109 |
| 2025 | 48 | — | 1 | 13,315 |
| 2026 | 31 | — | 3 | — |
What is it indicated for?
Defibrillator Function The E Series products contain a DC defilbrillator capableof delivering up to 200 joules of energy. It may be used insynchronized mode to perform synchronized cardioversion by using the R-wave of the patient's EGG as a timing reference. The unit uses paddles or disposable, pre-gelled, MFE Pads for dlefibrillation. The E Series products must be prescribed for use by a physician or medical advisor of an emergency response team.…
Read the full statement (888 words)
Defibrillator Function
The E Series products contain a DC defilbrillator capableof delivering up to 200 joules of energy. It may be used insynchronized mode to perform synchronized cardioversion by using the R-wave of the patient's EGG as a timing reference. The unit uses paddles or disposable, pre-gelled, MFE Pads for dlefibrillation. The E Series products must be prescribed for use by a physician or medical advisor of an emergency response team.
Intended Use - Manual Operation
Use of the E Series units inthe Manual mode for defilbrillation is indicated on victims of cardiac arrest where there is apparent lack of circulation as indicated by these three conditions:
• Unconsciousness
• Absence of breathing, and
* Absence of pulse.
This product should be used only by qualified medical personnel for converting ventricular fibrillation and rapid ventricular tachycardia to sinus rhythm or other cardiac rhythms capable of producing hemodynamically significant heart beats. In Manual mode, the E Series unit may also be used for synchronized cardioversion to terminate atrial fibrillation (AF) or ventricular tachycardias (VT) by using the Rwave of the patient's EGG as a timing reference. A qualified physician must decide when synchronized cardioversion is appropriate.The Advisory function should be used to confirm ventricular fibrillation and wide complex ventricular tachycardia (greater than 150 beats per minute) in patients meeting the three conditions indicating lack of circulation (previously listed).
Intended Use -- CPRReadyCharge Mode
Use of the E Series unit in GPRReadyCharge Mode is designed for use by qualified medical personnel who have been trained in AGLS (Advanced Cardiac Life Support). The purpose of the CPRReadyCharge algorithm is to anticipate the need to deliver a therapy shock. CPRReady~harge Mode uses an advisory algorithm that is designed to perform in the presence of CPR artifact. However, the accuracy of the CPRReady~harge algorithm inthe presence of CPR artifact is lower than the accuracy observed in the Advisory or Semiautomatic (AED) algorithm used with artifact-free EGG. The advisory result should always be confirmed through visual inspection of the EGG rhythm by the operator before the delivery of any therapy. See Table A-A in Appendix A for a summary ofthe performance.E Series products with CPRReady~harge Mode are specifically designed for use in early defilbrillation programs where the delivery of a dlefibrillator shock during resuscitation involving CPR, transportation, and definitive care are incorporated into a medically approved patient care protocol. Use of the E Series units inCPRReady~harge Mode for dlefibrillation is indicated on victims of cardiac arrest where there is apparent lack of circulation. E Series units in CPRReady~harge Mode, when used inconjunction with CPR-D padz, prompt the emergency care personnel to perform CPR, and perform rhythm analysis during GPR compressions. If an underlying shockable rhythm is detected during CPR, the E Series unit in CPRReady~harge Mode prepares the dlefibrillator to deliver a shock at the end of the CPR interval.
Intended Use - Semiautomatic Operation (AED)
The E Series AED unit is designed for use by emergency care personnel who have completed training and certification requirements applicable to the use of a defibrillator where the device operator controls delivery of shocks to the patient. They are specifically designed for use in early defibrillation programs where the delivery of a defibrillator shock during resuscitation involving CPR, transportation, and definitive care are incorporated into a medically-approved patient care protocol. Use of the device in the Semiautomatic mode for defibrillation is indicated on victims of cardiac arrest where there is apparent lack of circulation. Specifications for the EGG rhythm analysis function are provided at the end of this section.
Intended Use - CPR Monitoring
The CPR monitoring function provides visual and audio feedback designed to encourage rescuers to perform chest compressions at the AHAJERC recommended rate of 100 compressions per minute. Voice and visual prompts encourage a compression depth of 1.5 to 2 inches (3.8 to 5.0 cm) for adult patients. The CPR monitoring function is not intended for use on patients under 8 years of age.
Intended Use - Pacemaker
This product may be used for temporary external cardiac pacing inconscious or unconscious patients as an alternative to endocardial stimulation. Note: This device must not be connected to internal pacemaker electrodes. The purposes of pacinrg include:
Resuscitation from standstill or bradycardia ofany etiology
Noninvasive pacing has been used for resuscitation from cardiac standstill, reflex vagal standstill, drug induced standstill (due to procainamide, quinidine~digitalis, b-blockers, verapamil. etc.) and unexpected circulatory arrest (due to anesthesia, surgery~angiography, and other therapeutic or diagnostic procedures). It has also been used for temporary acceleration of bradycardia in Stokes-Adams disease and sick-sinus syndrome. It is safer, more reliable~and more rapidly applied in an emergency than endocardial or other temporary electrodes.
As a standby when standstill or bradycardia might be expected
Noninvasive pacing may be useful as a standby when cardiac arrest or symptomatic bradycardia might be expected due to acute myocardial infarction, drug toxicity, anesthesia or surgery. It is also useful as a temporary treatment inpatients awaiting pacemaker implants or the introduction of transvenous therapy. In standby pacing applications, noninvasive pacing may provide an alternative to transvenous therapy that avoids the risks of displacement, infection, hemorrhage, embolization, perforation, phlebitis and mechanical or electrical stimulation of ventricular tachycardia or fibrillation associated with endocardial pacing.
Suppression of tachycardia
Increased heart rates in response to external pacing often suppress ventricular ectopic attivity and may prevent tachycardia.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K091265 · printed Nov 4, 2026
Cite this page
510(k) Report. “K091265: Zoll E Series with Cprreadycharge.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K091265
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026