510(k) · Cleared
ClearedAmsco Evolution Series Steam Sterilizer, Model: HC-2000 and HC-3000
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
STERIS Corporation · FLE Sterilizer, Steam
Cleared on Nov 4, 2009 as substantially equivalent to K082435 (STERIS Corporation, 2008) and 1 other predicate after an 83-day review. Its family tree reaches back 4 generations to 2001. 1 later device descends from it.
- Decided
- Nov 4, 2009
- Review
- 83 days
- Class
- Class II
- Product code
- FLE
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 4 generations to K010865 (2001). 1 later device descends from it, 1 citing it directly.
- Root · 4 generations backK010865 Amsco Century Medium Sterilizer, Model CenturySTERIS Corporation · 2001 · Recalled
- 3 generations backK020747 Amsco Century Medium Sterilizer 26 X 26STERIS Corporation · 2002
- 2 generations backK082435 Amsco Evolution Medium Steam SterilizerSTERIS Corporation · 2008 · Recalled
- 1 generation backK091136 Amsco Evolution Medium Steam Sterilizer, Model HC-900 and HC-1200STERIS Corporation · 2009 · Recalled
- This deviceK092490 Amsco Evolution Series Steam Sterilizer, Model: HC-2000 and HC-3000STERIS Corporation · 2009
- Descendant · cites it directly · 0 of its ownK173493 Amsco Evolution Floorloader Steam Sterilizer HC-2000 and HC-3000STERIS Corporation · 2018
Most influential descendants
Showing 1 of 1 · See all- K173493Amsco Evolution Floorloader Steam Sterilizer HC-2000 and HC-3000STERIS Corporation · 2018 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K010865 | Amsco Century Medium Sterilizer, Model Century | STERIS Corporation | 2001 | 1 |
| −3 | K020747 | Amsco Century Medium Sterilizer 26 X 26 | STERIS Corporation | 2002 | — |
| −2 | K082435 | Amsco Evolution Medium Steam Sterilizer | STERIS Corporation | 2008 | 4 |
| −1 | K091136 | Amsco Evolution Medium Steam Sterilizer, Model HC-900 and HC-1200 | STERIS Corporation | 2009 | 3 |
| 0 (this device) | K092490 | Amsco Evolution Series Steam Sterilizer, Model: HC-2000 and HC-3000 | STERIS Corporation | 2009 | — |
| +1 | K173493 | Amsco Evolution Floorloader Steam Sterilizer HC-2000 and HC-3000 | STERIS Corporation | 2018 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2018 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FLE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FLE device
- #1 K250168 Life Ultra 25L Tabletop Mono Chamber Steam…score 12.7 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K082435 | Amsco Evolution Medium Steam SterilizerSummary page 2…nd HC-3000 Common/Usual Name: Steam Sterilizer Classification Name: Steam Sterilizer (21 CFR 880.6880, Product Code 80 FLE) Predicate Devices K082435, Amsco Evolution Medium Steam Sterilizer (Models HC-600 and HC-1500) cleared December 30, 2008. K091136, Amsco Evolution Mediu… | 2008 |
| * | K091136 | Amsco Evolution Medium Steam Sterilizer, Model HC-900 and HC-1200Summary page 2…r (21 CFR 880.6880, Product Code 80 FLE) Predicate Devices K082435, Amsco Evolution Medium Steam Sterilizer (Models HC-600 and HC-1500) cleared December 30, 2008. K091136, Amsco Evolution Medium Steam Sterilizer (Models HC-900 and HC-1200) cleared June 29, 2009. Description of Device The Amsco E… | 2009 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K173493 | Amsco Evolution Floorloader Steam Sterilizer HC-2000 and HC-3000 | 2018 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 8 years and passes through 1 company; a new generation was cleared every 12 months on median.
- 3 of the 4 ancestors have a recall of any class.
- Of its descendants, K173493 (STERIS Corporation, 2018) has gone furthest, with 0 descendants of its own.
- 3 other devices also cite its predicate K082435.
How does its category compare?
All FLE devicesFLE Sterilizer, Steam: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · FLE
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FLE
184in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FLE
1in 2021
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FLE
71in 2025
MAUDE reports naming product code FLE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 67 | 1 | 19 |
| 2008 | 1 | — | 1 | 21 |
| 2009 | 8 | 109 | 0 | 19 |
| 2010 | 2 | — | 0 | 20 |
| 2011 | 5 | 141 | 1 | 63 |
| 2012 | 5 | 111 | 1 | 69 |
| 2013 | 5 | 241 | 2 | 112 |
| 2014 | 2 | — | 0 | 113 |
| 2015 | 3 | 302 | 1 | 68 |
| 2016 | 1 | — | 0 | 76 |
| 2017 | 3 | 233 | 0 | 63 |
| 2018 | 8 | 146 | 1 | 90 |
| 2019 | 5 | 192 | 2 | 91 |
| 2020 | 2 | — | 0 | 87 |
| 2021 | 5 | 147 | 1 | 81 |
| 2022 | 10 | 133 | 0 | 70 |
| 2023 | 7 | 88 | 0 | 66 |
| 2024 | 2 | — | 0 | 64 |
| 2025 | 4 | 184 | 0 | 71 |
| 2026 | 3 | 85 | 1 | — |
What is it indicated for?
The Amsco Evolution Series Steam Sterilizer Models HC-2000 and HC-3000 are designed for sterilization of heat and moisture-stable materials used in healthcare facilities and are available in two configurations: * Prevacuum - is equipped with Prevacuum, Gravity, Liquid, Leak Test and DART (Bowie-Dick) cycles. * Steam Flush Pressure-Pulse(SFPP)- is equipped with SFPP, Prevacuum, Gravity, Liquid, Leak Test and DART (Bowie-Dick) cycles. The Amsco Evolution…
Read the full statement (648 words)
The Amsco Evolution Series Steam Sterilizer Models HC-2000 and HC-3000 are designed for sterilization of heat and moisture-stable materials used in healthcare facilities and are available in two configurations:
* Prevacuum - is equipped with Prevacuum, Gravity, Liquid, Leak Test and DART
(Bowie-Dick) cycles.
* Steam Flush Pressure-Pulse(SFPP)- is equipped with SFPP, Prevacuum,
Gravity, Liquid, Leak Test and DART (Bowie-Dick) cycles.
The Amsco Evolution Series Prevacuum Steam Sterilizer is equipped with the following
factory-programmed sterilization cycles and cycle values (Table 4-1):
Table 4-1. Amsco Evolution Series Prevacuum Steam Sterilizer
factor -rorammed sterilization cycles and ycle values
Prevac 270° (132°C) 4 minutes 30 minutes Double wrapped instrument
trays, maximum weight 25
lbs (11.3 kg) each and
Fabric Packs. Refer to
Table 4-3 for recommended
quantities.
Prevac 2700 F (132°C) 4 minutes 5 minutes Single Fabric Pack
Gravity 250°F (121°C) 30 minutes 15 minutes Fabric Packs. Refer to
Table 4-3 for recommended
quantities.
Liquid* 250W (121 0 C) 45 minutes N/A Refer to Table 4-4for
recommended quantities.
Prevac 275F (135°C) 3 minutes 30 minutes Double wrapped instrument
trays, maximum weight 25
lbs (11.3 kg) each. Refer to
Table 4-3for recommended
quantities.
"гиCycles~ sPa~ ~~~ ie~4%?fii~f~4•W
mmtS~iie,
Gravity 270F (132°C) 15 minutes 45 minutes Double wrapped instrument
trays, maximum weight 25
lbs (11.3 kg) each. Refer to
Table 4-3for recommended
quantities.
Gravity 250°F (121°C) 30 minutes 45 minutes Double wrapped instrument
trays, maximum weight 25
lbs (11.3 kg) each. Refer to
Table 4-3for recommended
quantities.
Gravity 270°F (132 0 C) 25 minutes 15 minutes Fabric Packs. Refer to
Table 4-3 for recommended
quantities.
DART 270° (132°C) 3 minutes 1 minute N/A
Warm-Up
DART 270° (132 0 C) 3 ½2 minutes 1 minute Bowie-Dick Test Pack,
DART Test Pack
Leak Test N/A N/A N/A N/A
*The liquid cycle is for non-patient contact use only.
The Amsco Evolution Series Steam Flush Pressure-Pulse(SFPP) Sterilizer is equipped
with the following factory-programmed sterilization cycles and cycle values (Table 4-2):
Table 4-2. Amsco Evolution Series Steam Flush Pressure-Pulse(SFPP)
Sterilizer factory- ro ammed sterilization c cles and c cle values
SFPP 270° (132 0 C) 4 minutes 45 minutes Double wrapped instrument
trays, maximum weight 25
lbs (11.3 kg) each and Fabric
Packs. Refer to Table 4-3 for
recommended quantities.
SFPP 275° (135°C) 3 minutes 45 minutes Double wrapped instrument
trays, maximum weight 25
lbs (11.3 kg) each. Refer to
Table 4-3for recommended
quantities.
Ye Stenhize x~,Vw
»s~OStenze 3 .Eny Time;
ITm fip~eratureg.________
,*s
Prevac 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument
trays, maximum weight 25
lbs (11.3 kg) each and Fabric
Packs. Refer to Table 4-3for
recommended quantities.
Gravity 250°F (121°C) 30 minutes 15 minutes Fabric Packs. Refer to Table
4-3for recommended
quantities.
SFPP 270F (132°C) 4 minutes 5 minutes Single Fabric Pack
Prevac 275F (135°C) 3 minutes 30 minutes Double wrapped instrument
trays, maximum weight 25
lbs (11.3 kg) each. Refer to
Table 4-3for recommended
quantities.
Gravity 270F (132°C) 15 minutes 45 minutes Double wrapped instrument
trays, maximum weight 25
lbs (11.3 kg) each. Refer to
Table 4-3 for recommended
quantities.
Liquid* 250° (121°C) 45 minutes N/A Refer to Table 4-4for
recommended quantities.
DART 270° (132 0 C) 3 minutes 1 minute N/A
Warm-Up
DART 270F (132 0 C) 3 ½2 minutes 1 minute Bowie-Dick Test Pack,
_______I_ DART Test Pack
Leak Test N/A N/A N/A N/A
*The liquid cycle is for non-patient contact use only.
The following table lists STERIS's recommended loads by sterilizer size:
Table 4-3. Amsco Evolution Series Steam
Sterilizer recommended loads per sterilizer size
26" x 61" x 49" HC-2000 15 40
26" x 61" x 72" HC-3000 25 60
The following table is a guideline for liquid cycle processing:
Table 4-4. Amsco Evolution Series Steam
Sterilizer Liquid Cycle Guideline
Kb
-Numfber~o4K' R~1~L.... '
13 L 1000 ml 45 minutes
The Amsco Evolution Series Steam Sterilizer is offered in the following chamber sizes:
* ModelHC-2000 26"x61"x49"
· Model HGC-3000 26"x61"x72"
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K092490 · printed Nov 4, 2026
Cite this page
510(k) Report. “K092490: Amsco Evolution Series Steam Sterilizer, Model: HC-2000 and HC-3000.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K092490
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026