510(k) Report

510(k) · Cleared

Recalled · Class II · 2018

Amsco Evolution Medium Steam Sterilizer, Model HC-900 and HC-1200

K091136510(k) AbbreviatedCleared Jun 29, 200970-day reviewClass II21 CFR 880.6880Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

STERIS Corporation · FLE Sterilizer, Steam

Cleared on Jun 29, 2009 as substantially equivalent to K082435 (STERIS Corporation, 2008) after a 70-day review. Its family tree reaches back 3 generations to 2001. 4 later devices descend from it. It has been recalled 3 times.

Decided
Jun 29, 2009
Review
70 days
Class
Class II
Product code
FLE
Recalls
3
Predicates
1

Its longest line of descent runs back 3 generations to K010865 (2001). 4 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2009: 1 descendant cleared2018: 2 descendants cleared2020: 1 descendant clearedK010865 · Amsco Century Medium Sterilizer, Model Century · STERIS Corporation · 2001 · recalledK020747 · Amsco Century Medium Sterilizer 26 X 26 · STERIS Corporation · 2002K082435 · Amsco Evolution Medium Steam Sterilizer · STERIS Corporation · 2008 · recalled200020052010201520202025
  1. Root · 3 generations backK010865 Amsco Century Medium Sterilizer, Model CenturySTERIS Corporation · 2001 · Recalled
  2. 2 generations backK020747 Amsco Century Medium Sterilizer 26 X 26STERIS Corporation · 2002
  3. 1 generation backK082435 Amsco Evolution Medium Steam SterilizerSTERIS Corporation · 2008 · Recalled
  4. This deviceK091136 Amsco Evolution Medium Steam Sterilizer, Model HC-900 and HC-1200STERIS Corporation · 2009
  5. Descendant · cites it directly · 1 of its ownK173481 Amsco Evolution Medium Steam SterilizerSTERIS Corporation · 2018
  6. Descendant · cites it directly · 1 of its ownK092490 Amsco Evolution Series Steam Sterilizer, Model: HC-2000 and HC-3000STERIS Corporation · 2009
  7. Descendant · 2 generations on · 0 of its ownK203061 Amsco Evolution Medium Steam Sterilizer (Models HC-900 and…STERIS Corporation · 2020
  8. Descendant · 2 generations on · 0 of its ownK173493 Amsco Evolution Floorloader Steam Sterilizer HC-2000 and HC-3000STERIS Corporation · 2018

Most influential descendants

Showing 4 of 4 · See all
  • K173481Amsco Evolution Medium Steam SterilizerSTERIS Corporation · 2018 · cites it directly1descendant
  • K092490Amsco Evolution Series Steam Sterilizer, Model: HC-2000 and HC-3000STERIS Corporation · 2009 · cites it directly1descendant
  • K203061Amsco Evolution Medium Steam Sterilizer (Models HC-900 and HC-1200),Evolution Automated…STERIS Corporation · 2020 · 2 generations on0descendants
  • K173493Amsco Evolution Floorloader Steam Sterilizer HC-2000 and HC-3000STERIS Corporation · 2018 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K010865Amsco Century Medium Sterilizer, Model CenturySTERIS Corporation20011
−2K020747Amsco Century Medium Sterilizer 26 X 26STERIS Corporation2002—
−1K082435Amsco Evolution Medium Steam SterilizerSTERIS Corporation20084
0 (this device)K091136Amsco Evolution Medium Steam Sterilizer, Model HC-900 and HC-1200STERIS Corporation2009—
+1K173481Amsco Evolution Medium Steam SterilizerSTERIS Corporation2018—
+1K092490Amsco Evolution Series Steam Sterilizer, Model: HC-2000 and HC-3000STERIS Corporation2009—
+2K203061Amsco Evolution Medium Steam Sterilizer (Models HC-900 and HC-1200),Evolution…STERIS Corporation2020—
+2K173493Amsco Evolution Floorloader Steam Sterilizer HC-2000 and HC-3000STERIS Corporation2018—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201820
202010
FIG. 1 — Lineage of K091136, 2001–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FLE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FLE device

  1. #1 K250168 Life Ultra 25L Tabletop Mono Chamber Steam…score 12.7 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K082435Amsco Evolution Medium Steam Sterilizer
Summary page 2
…Classification Name: Steam Sterilizer (21 CFR 880.6880) Product Code 80 FLE 2. Predicate Device K082435, Amsco Evolution Medium Steam Sterilizer, product code [FLE] cleared December 30, 2008. 3. Description of Devic…
STERIS Corporation20084

Also cleared against K082435: 3 other devices →

What descends from it? (4)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K173481Amsco Evolution Medium Steam SterilizerSTERIS Corporation20181
K092490Amsco Evolution Series Steam Sterilizer, Model: HC-2000 and HC-3000STERIS Corporation20091

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Dec 26, 2018Class IIZ-0824-2019Device DesignThe ATLAS loading car may not remain fully engaged with the latch on the transfer carriage when the loading car is empty, potentially resulting in the loading car unexpectedly sliding forward or falling to one side.
Oct 18, 2013Class IIZ-0478-2014Device DesignThe firm discovered that unlatching can occur when overloaded transfer carriages are pulled or maneuvered incorrectly or with excessive force.
Mar 23, 2012Not classifiedZ-1522-2012Device DesignThrough Customer feedback and field service experience, STERIS learned that operators may experience difficulty when inserting or removing equipment from the Evolution sterilizer using the transfer carriage due to the following issues…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 8 years and passes through 1 company; a new generation was cleared every 12 months on median.
  • 2 of the 3 ancestors have a recall of any class.
  • Of its descendants, K173481 (STERIS Corporation, 2018) has gone furthest, with 1 descendant of its own.
  • 3 other devices also cite its predicate K082435.

How does its category compare?

All FLE devices

FLE Sterilizer, Steam: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · FLE

4in 2025

2007: 52008: 12009: 82010: 22011: 52012: 52013: 52014: 22015: 32016: 12017: 32018: 82019: 52020: 22021: 52022: 102023: 72024: 22025: 42026 (partial year): 3
2007high 10 (2022) · low 1 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FLE

184in 2025

2007: 67 days median2009: 109 days median2011: 141 days median2012: 111 days median2013: 241 days median2015: 302 days median2017: 233 days median2018: 146 days median2019: 192 days median2021: 147 days median2022: 133 days median2023: 88 days median2025: 184 days median2026 (partial year): 85 days median
2007high 302 (2015) · low 67 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FLE

1in 2021

2007: 12008: 12011: 12012: 12013: 22015: 12018: 12019: 22021: 12026 (partial year): 1
2007high 2 (2013) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FLE

71in 2025

2007: 192008: 212009: 192010: 202011: 632012: 692013: 1122014: 1132015: 682016: 762017: 632018: 902019: 912020: 872021: 812022: 702023: 662024: 642025: 71
2007high 113 (2014) · low 19 (2007)2025

MAUDE reports naming product code FLE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007567119
20081—121
20098109019
20102—020
20115141163
20125111169
201352412112
20142—0113
20153302168
20161—076
20173233063
20188146190
20195192291
20202—087
20215147181
202210133070
2023788066
20242—064
20254184071
20263851—

What is it indicated for?

The Amsco Evolution Medium Steam Sterilizer Models HC-900 and HC-1200 are designed for sterilization of heat and moisture-stable materials used in healthcare facilities and are available in two configurations: * Prevacuum - is equipped with Prevacuum, Gravity, Liquid, Leak Test and DART (Bowie-Dick) cycles. * Steam Flush Pressure-Pulse(SFPP)- is equipped with SFPP, Prevacuum, Gravity, Liquid, Leak Test and DART (Bowie-Dick) cycles. The Amsco Evolution…

Read the full statement (638 words)

The Amsco Evolution Medium Steam Sterilizer Models HC-900 and HC-1200 are designed for sterilization of heat and moisture-stable materials used in healthcare facilities and are available in two configurations:

* Prevacuum - is equipped with Prevacuum, Gravity, Liquid, Leak Test and DART (Bowie-Dick) cycles.

* Steam Flush Pressure-Pulse(SFPP)- is equipped with SFPP, Prevacuum, Gravity, Liquid, Leak Test and DART (Bowie-Dick) cycles.

The Amsco Evolution Medium Prevacuum Steam Sterilizer is equipped with the following factory-programmed sterilization cycles and cycle values (Table 4-1):

Table 4-1. Amsco Evolution Medium Prevacuum Steam Sterilizer factory-programmed sterilization cycles and cycle values

Prevac 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each and Fabric Packs. Refer to Table 4-3 for recommended quantities.

Prevac 270°F (132°C) 4 minutes 5 minutes Single Fabric Pack

Gravity 250°F (121°C) 30 minutes 15 minutes Fabric Packs. Refer to Table 4-3 for recommended quantities.

Liquid 250°F (121°C) 45 minutes N/A Refer to Table 4-4 for recommended quantities.

Prevac 275°F (135°C) 3 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 4-3 for recommended quantities.

Gravity 270°F (132°C) 15 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 4-3 for recommended quantities.

Gravity 250°F (121°C) 30 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 4-3 for recommended quantities.

Gravity 270°F (132°C) 25 minutes 15 minutes Fabric Packs. Refer to Table 4-3 for recommended quantities.

DART Warm-Up 270°F (132°C) 3 minutes 1 minute N/A

DART 270°F (132°C) 3 ½ minutes 1 minute Bowie-Dick Test Pack, DART Test Pack

Leak Test N/A N/A N/A N/A

*The liquid cycle is for non-patient contact use only.

The Amsco Evolution Medium Steam Flush Pressure-Pulse(SFPP) Sterilizer is equipped with the following factory-programmed sterilization cycles and cycle values (Table 4-2):

Table 4-2. Amsco Evolution Medium Steam Flush Pressure-Pulse(SFPP) Sterilizer factory-programmed sterilization cycles and cycle values

SFPP 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each and Fabric Packs. Refer to Table 4-3 for recommended quantities.

SFPP 275°F (135°C) 3 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 4-3 for recommended quantities.

Prevac 270°F (132°C) 4 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each and Fabric Packs. Refer to Table 4-3 for recommended quantities.

Gravity 250°F (121°C) 30 minutes 15 minutes Fabric Packs. Refer to Table 4-3 for recommended quantities.

SFPP 270°F (132°C) 4 minutes 5 minutes Single Fabric Pack

Prevac 275°F (135°C) 3 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 4-3 for recommended quantities.

Gravity 270°F (132°C) 15 minutes 30 minutes Double wrapped instrument trays, maximum weight 25 lbs (11.3 kg) each. Refer to Table 4-3 for recommended quantities.

Liquid 250°F (121°C) 45 minutes N/A Refer to Table 4-4 for recommended quantities.

DART Warm-Up 270°F (132°C) 3 minutes 1 minute N/A

DART 270°F (132°C) 3 ½ minutes 1 minute Bowie-Dick Test Pack, DART Test Pack

Leak Test N/A N/A N/A N/A

*The liquid cycle is for non-patient contact use only.

The following table lists STERIS's recommended loads by sterilizer size:

Table 4-3. Amsco Evolution Medium Steam Sterilizer recommended loads per sterilizer size

26" x 37 ½" x 42" 12 18

26" x 37 ½" x 54" 16 30

The following table is a guideline for liquid cycle processing:

Table 4-4. Amsco Evolution Medium Steam Sterilizer Liquid Cycle* Guideline

3 1000 ml 45 minutes

*The liquid cycle is for non-patient contact use only.

The Amsco Evolution Medium Steam Sterilizer is offered in the following chamber sizes:

* 26" x 37½" x 42" (Model HC - 900)

* 26" x 37½" x 54" (Model HC-1200)

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K091136: Amsco Evolution Medium Steam Sterilizer, Model HC-900 and HC-1200.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K091136

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.