510(k) Report

510(k) · Cleared

Recalled · Class II · 2016

Neuviz 16 Multi-Slice CT Scanner System

K092742510(k) TraditionalCleared Sep 22, 200914-day reviewClass II21 CFR 892.1750Recalls 5

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Neusoft Medical Systems Co., Ltd. · JAK System, X-Ray, Tomography, Computed

Cleared on Sep 22, 2009 after a 14-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 3 later devices descend from it. It has been recalled 5 times.

Decided
Sep 22, 2009
Review
14 days
Class
Class II
Product code
JAK
Recalls
5
Predicates
0

3 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2012: 1 descendant cleared2017: 1 descendant cleared2014: 1 descendant cleared20052010201520202025
  1. This deviceK092742 Neuviz 16 Multi-Slice CT Scanner SystemNeusoft Medical Systems Co., Ltd. · 2009
  2. Descendant · cites it directly · 1 of its ownK121792 Neuviz 64 Multi-Slice CT Scanner SystemNeusoft Medical Systems Co., Ltd. · 2012 · Recalled
  3. Descendant · cites it directly · 0 of its ownK171198 NeuViz 16 Essence Multi-slice CT Scanner SystemNeusoft Medical Systems Co., Ltd. · 2017 · Recalled
  4. Descendant · 2 generations on · 0 of its ownK133373 ClearviewNeusoft Medical Systems Co., Ltd. · 2014

Most influential descendants

Showing 3 of 3 · See all
  • K121792Neuviz 64 Multi-Slice CT Scanner SystemNeusoft Medical Systems Co., Ltd. · 2012 · cites it directly1descendant
  • K171198NeuViz 16 Essence Multi-slice CT Scanner SystemNeusoft Medical Systems Co., Ltd. · 2017 · cites it directly0descendants
  • K133373ClearviewNeusoft Medical Systems Co., Ltd. · 2014 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K092742Neuviz 16 Multi-Slice CT Scanner SystemNeusoft Medical Systems Co., Ltd.2009—
+1K121792Neuviz 64 Multi-Slice CT Scanner SystemNeusoft Medical Systems Co., Ltd.20125
+1K171198NeuViz 16 Essence Multi-slice CT Scanner SystemNeusoft Medical Systems Co., Ltd.20171
+2K133373ClearviewNeusoft Medical Systems Co., Ltd.2014—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201210
201410
201710
FIG. 1 — Lineage of K092742, 2009–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JAK device

  1. #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (3)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K121792Neuviz 64 Multi-Slice CT Scanner SystemNeusoft Medical Systems Co., Ltd.20121
K171198NeuViz 16 Essence Multi-slice CT Scanner SystemNeusoft Medical Systems Co., Ltd.20170

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 24, 2016Class IIZ-1573-2016Under Investigation by firmThe following issues are found in NeuViz 16 systems with software version 1.1.4.21425 and version 1.1.4.21426: 1) During the filming operation on MX 16-slice console software, the clipboard used for copying and pasting images is not…
Mar 4, 2013Class IIZ-1165-2013Use errorUser error of the NeuViz 16 or NeuViz Dual may cause personnel injuries. There was a report where a finger was pinched when the table was moved backward while the tabletop was controlled by another person from the gantry left control panel.
Oct 18, 2012Class IIZ-0466-2013Device DesignThe four screws that secure the patient table top to the carrier pulled out and caused the table top to detach. This issue may affect NeuViz Dual and NeuViz 16 scanners.
Jun 8, 2012Class IIZ-2083-2012Device DesignOne of the four screws that secure the Oil-accumulator to the X-Ray Tube pulled out in the NeuViz 16 CT scanner, which caused the Oil-accumulator to detach.
Feb 9, 2011Not classifiedZ-2241-2011OtherDimension measurement displays on a combined image were found inaccurate after the clinician merged multiple image series into one image.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K121792 (Neusoft Medical Systems Co., Ltd., 2012) has gone furthest, with 1 descendant of its own.

How does its category compare?

All JAK devices

JAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · JAK

27in 2025

2007: 142008: 262009: 152010: 72011: 162012: 282013: 172014: 302015: 302016: 252017: 292018: 242019: 282020: 302021: 202022: 302023: 272024: 262025: 272026 (partial year): 21
2007high 30 (2014) · low 7 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JAK

141in 2025

2007: 27 days median2008: 42 days median2009: 31 days median2010: 92 days median2011: 155 days median2012: 121 days median2013: 132 days median2014: 200 days median2015: 140 days median2016: 129 days median2017: 96 days median2018: 114 days median2019: 94 days median2020: 112 days median2021: 145 days median2022: 131 days median2023: 139 days median2024: 141 days median2025: 141 days median2026 (partial year): 167 days median
2007high 200 (2014) · low 27 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JAK

17in 2025

2007: 112008: 162009: 292010: 512011: 342012: 232013: 112014: 102015: 282016: 442017: 332018: 102019: 52020: 82021: 152022: 92023: 92024: 202025: 172026 (partial year): 23
2007high 51 (2010) · low 5 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JAK

219in 2025

2007: 762008: 1202009: 1052010: 1192011: 2052012: 1922013: 4142014: 3082015: 4542016: 3652017: 3382018: 5432019: 2332020: 1772021: 2612022: 1992023: 3102024: 2122025: 219
2007high 543 (2018) · low 76 (2007)2025

MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200714271176
2008264216120
2009153129105
201079251119
20111615534205
20122812123192
20131713211414
20143020010308
20153014028454
20162512944365
2017299633338
20182411410543
201928945233
2020301128177
20212014515261
2022301319199
2023271399310
20242614120212
20252714117219
20262116723—

What is it indicated for?

The NeuViz 16 Multi-Slice CT Scanner System can be used as a whole body computed tomography X-ray system featuring a continuously rotating'X-ray tube and detector array with multislice capability up to 16 slices simultaneously. The acquired X-RAY'transmission data is reconstructed by computer into cross-sectional imagers of the body from the same axial plane taken at different angles. The system is suitable for all patients.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K092742: Neuviz 16 Multi-Slice CT Scanner System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K092742

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026