510(k) Report

510(k) · Cleared

Cleared

CAPNOSTREAM20 with MICROMEDICO2 Module

K094012510(k) SpecialCleared May 12, 2010134-day reviewClass II21 CFR 868.1400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Oridion Capnography, Inc. · CCK Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase

Cleared on May 12, 2010 as substantially equivalent to K082268 (Oridion Capnography, Inc., 2009) after a 134-day review. Its family tree reaches back 11 generations to 1997. 2 of the 131 devices in its family, counting itself, have a Class I recall. 93 later devices descend from it.

Decided
May 12, 2010
Review
134 days
Class
Class II
Product code
CCK
Recalls
None
Predicates
1

Its longest line of descent runs back 11 generations to K962603 (1997). 37 ancestors in all, the oldest K893221 (1990). 93 later devices descend from it, 8 citing it directly. 2 of the 131 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2005: 1 other ancestor2004: 1 other ancestor2002: 1 other ancestor2003: 1 other ancestor2000: 1 other ancestor1999: 3 other ancestors1995: 4 other ancestors1990: 2 other ancestors1998: 4 other ancestors1997: 2 other ancestors, 1 with a Class I recall11996: 2 other ancestors1991: 2 other ancestors1993: 1 other ancestor1992: 1 other ancestor2014: 10 descendants cleared, 1 with a Class I recall12013: 2 descendants cleared2019: 8 descendants cleared2015: 5 descendants cleared2011: 1 descendant cleared2012: 4 descendants cleared2017: 4 descendants cleared2016: 3 descendants cleared2018: 3 descendants cleared2022: 12 descendants cleared2021: 3 descendants cleared2024: 11 descendants cleared2020: 6 descendants cleared2023: 6 descendants cleared2026: 7 descendants cleared2025: 8 descendants clearedK962603 · Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables · Masimo Corp. · 1997K973887 · Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables · Masimo Corp. · 1998K982255 · Model 2000 Pulse Oximeter · Ivy Biomedical Systems, Inc. · 1998K991823 · N-395 Pulse Oximeter, Model N-395 · Nellcor Puritan Bennett, Inc. · 1999×2: 2 generations cleared close together, K012891 (2002), K021090 (2002) K033048 · Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS, 740-2NL, 740M-2NL, 740-2NN, 740M-2NN, 740-3MS, 740M-3MS · Cas Medical Systems, Inc. · 2004 · recalledK050844 · 750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL, 750CM-2NL, 750C-3MS, 750CM-3MS, 750C-3NL, 750CM-3NL · Cas Medical Systems, Inc. · 2005K060065 · CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter Bedside Monitor · Oridion Capnography, Inc. · 2006 · recalledK072295 · Capnostream 20 with A2 Adaptive Averaging Software · Oridion Capnography, Inc. · 2007K082268 · CAPNOSTREAM20 with Integrated Pulmonary Index · Oridion Capnography, Inc. · 2009 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 4 generations back: 3 other ancestors5 generations back: 9 other ancestors6 generations back: 7 other ancestors, 1 with a Class I recall17 generations back: 5 other ancestors8 generations back: 2 other ancestors 1 generation forward: 8 descendants2 generations forward: 11 descendants3 generations forward: 12 descendants, 1 with a Class I recall14 generations forward: 10 descendants5 generations forward: 8 descendants6 generations forward: 12 descendants7 generations forward: 20 descendants8 generations forward: 11 descendants9 generations forward: 1 descendant K082268 · CAPNOSTREAM20 with Integrated Pulmonary Index · Oridion Capnography, Inc. · 2009 · recalledK072295 · Capnostream 20 with A2 Adaptive Averaging Software · Oridion Capnography, Inc. · 2007K060065 · CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter Bedside Monitor · Oridion Capnography, Inc. · 2006 · recalledK050844 · 750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL, 750CM-2NL, 750C-3MS, 750CM-3MS, 750C-3NL, 750CM-3NL · Cas Medical Systems, Inc. · 2005K033048 · Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS, 740-2NL, 740M-2NL, 740-2NN, 740M-2NN, 740-3MS, 740M-3MS · Cas Medical Systems, Inc. · 2004 · recalledK021090 · Oximax N-550 Pulse Oximeter,Model N-550 Pulse Oximeter · Nellcor Puritan Bennett, Inc. · 2002K012891 · Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax Sensors and Cables (Aka Accessories) · Nellcor Puritan Bennett, Inc. · 2002 · recalledK991823 · N-395 Pulse Oximeter, Model N-395 · Nellcor Puritan Bennett, Inc. · 1999K982255 · Model 2000 Pulse Oximeter · Ivy Biomedical Systems, Inc. · 1998K973887 · Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables · Masimo Corp. · 1998K962603 · Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables · Masimo Corp. · 1997−10−50+5
  1. Root · 11 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 7 generations between
  3. 3 generations backK060065 CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One…Oridion Capnography, Inc. · 2006 · Recalled
  4. 2 generations backK072295 Capnostream 20 with A2 Adaptive Averaging SoftwareOridion Capnography, Inc. · 2007
  5. 1 generation backK082268 CAPNOSTREAM20 with Integrated Pulmonary IndexOridion Capnography, Inc. · 2009 · Recalled
  6. This deviceK094012 CAPNOSTREAM20 with MICROMEDICO2 ModuleOridion Capnography, Inc. · 2010
  7. Descendant · cites it directly · 65 of its ownK121013 Connex Vital Signs Monitor 6000 SeriesWelch Allyn, Inc. · 2012
  8. Descendant · 2 generations on · 58 of its ownK140188 Masimo Root Monitoring SystemMasimo Corporation · 2014
  9. Descendant · 3 generations on · 51 of its ownK142394 Masimo Root Monitoring System and AccesoriesMasimo Corporation · 2014
  10. Descendant · 4 generations on · 24 of its ownK151644 Masimo Root Vital Signs Monitoring System and AccessoriesMasimo Corporation · 2016
  11. Descendant · 4 generations on · 24 of its ownK150314 Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation · 2015
Show all 11 generations
  1. Root · 11 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 10 generations backK973887 Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and…Masimo Corp. · 1998
  3. 9 generations backK982255 Model 2000 Pulse OximeterIvy Biomedical Systems, Inc. · 1998
  4. 8 generations backK991823 N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc. · 1999
  5. 7 generations backK012891 Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax…Nellcor Puritan Bennett, Inc. · 2002 · Recalled
  6. 6 generations backK021090 Oximax N-550 Pulse Oximeter,Model N-550 Pulse OximeterNellcor Puritan Bennett, Inc. · 2002
  7. 5 generations backK033048 Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS…Cas Medical Systems, Inc. · 2004 · Recalled
  8. 4 generations backK050844 750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL…Cas Medical Systems, Inc. · 2005
  9. 3 generations backK060065 CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One…Oridion Capnography, Inc. · 2006 · Recalled
  10. 2 generations backK072295 Capnostream 20 with A2 Adaptive Averaging SoftwareOridion Capnography, Inc. · 2007
  11. 1 generation backK082268 CAPNOSTREAM20 with Integrated Pulmonary IndexOridion Capnography, Inc. · 2009 · Recalled
  12. This deviceK094012 CAPNOSTREAM20 with MICROMEDICO2 ModuleOridion Capnography, Inc. · 2010

Showing 5 of 93 descendants. See all descendants

Descendants cleared per year

2011: 12012: 42013: 22014: 102015: 52016: 32017: 42018: 32019: 82020: 62021: 32022: 122023: 62024: 112025: 82026: 7
2011high 12 (2022) · low 1 (2011)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 93 · See all
  • K121013Connex Vital Signs Monitor 6000 SeriesWelch Allyn, Inc. · 2012 · cites it directly65descendants
  • K140188Masimo Root Monitoring SystemMasimo Corporation · 2014 · 2 generations on58descendants
  • K142394Masimo Root Monitoring System and AccesoriesMasimo Corporation · 2014 · 3 generations on51descendants
  • K151644Masimo Root Vital Signs Monitoring System and AccessoriesMasimo Corporation · 2016 · 4 generations on24descendants
  • K150314Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation · 2015 · 4 generations on24descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−11K962603Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp.1997—
−10K973887Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and CablesMasimo Corp.1998—
−9K982255Model 2000 Pulse OximeterIvy Biomedical Systems, Inc.1998—
−8K991823N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc.1999—
−7K012891Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax Sensors and…Nellcor Puritan Bennett, Inc.20021
−6K021090Oximax N-550 Pulse Oximeter,Model N-550 Pulse OximeterNellcor Puritan Bennett, Inc.2002—
−5K033048Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS, 740-2NL…Cas Medical Systems, Inc.20041
−4K050844750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL, 750CM-2NL…Cas Medical Systems, Inc.2005—
−3K060065CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter…Oridion Capnography, Inc.20063
−2K072295Capnostream 20 with A2 Adaptive Averaging SoftwareOridion Capnography, Inc.2007—
−1K082268CAPNOSTREAM20 with Integrated Pulmonary IndexOridion Capnography, Inc.20099
0 (this device)K094012CAPNOSTREAM20 with MICROMEDICO2 ModuleOridion Capnography, Inc.2010—
+1K121013Connex Vital Signs Monitor 6000 SeriesWelch Allyn, Inc.2012—
+2K140188Masimo Root Monitoring SystemMasimo Corporation2014—
+3K142394Masimo Root Monitoring System and AccesoriesMasimo Corporation2014—
+4K151644Masimo Root Vital Signs Monitoring System and AccessoriesMasimo Corporation2016—
+4K150314Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199020
199120
199210
199310
199540
199620
199721
199840
199930
200010
200210
200310
200410
200510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201240
201320
2014101
201550
201630
201740
201830
201980
202060
202130
2022120
202360
2024110
202580
202670
FIG. 1 — Lineage of K094012, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CCK device

  1. #1 K253030 Capnostream™35 Portable Respiratory Monitor…score 15.8 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K082268CAPNOSTREAM20 with Integrated Pulmonary Index
Summary page 4
…Capnostream2O Bedside Predicate Device- Capnostream2O Monitor with Bedside Monitor K082268 microMediCO2CO2 module Indications for The indications for use are identical to The Capnostream2O…
Oridion Capnography, Inc.20099

Also cleared against K082268: 2 other devices →

What descends from it? (93)

See all 93

8 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K121013Connex Vital Signs Monitor 6000 SeriesWelch Allyn, Inc.201265
K112432Zoll X SeriesZoll Medical Corporation, World Wide Headquarters20128
K101995Capnostream 20P with Masimo SPO2 BoardOridion Capnography, Inc.20117
K123900Suresigns VM4, Suresigns VM6, Suresigns VM8Philips Medical Systems20135
K133961Suresigns VS3, Suresigns VS4Philips Medical Systems20143
K140430740 SelectCas Medical Systems, Inc.20141
K180902MediPines Gas Exchange Monitor (GEM), Accessory Mouthpiece Disposable AssemblyMedipines Corporation20190
K150030Fukuda Denshi DynaScope Model DS-8000 Series Patient MonitorFukuda Denshi USA, Inc.20150

Has anything in its family been recalled? (2 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K970209Capnocheck PlusBci Intl., Inc. · 1997 · 6 generations back · ◆ in the 1997 ancestors bar of FIG. 11 Class I recall
  • K123690CAPNOSTREAM20P with Hifi C02 MonitoringOridion Medical 1987, Ltd. · 2014 · 3 generations on · ◆ in the 2014 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 13 years and passes through 5 companies; a new generation was cleared every 1.1 years on median.
  • 8 of the 37 ancestors have a recall of any class; 1 has a Class I recall.
  • Of its descendants, K121013 (Welch Allyn, Inc., 2012) has gone furthest, with 65 descendants of its own.
  • 2 other devices also cite its predicate K082268.

How does its category compare?

All CCK devices

CCK Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · CCK

3in 2025

2007: 52008: 32009: 32010: 32011: 22012: 72013: 42014: 92015: 52016: 22017: 52018: 62019: 72020: 42021: 42022: 32023: 42024: 32025: 32026 (partial year): 3
2007high 9 (2014) · low 2 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CCK

169in 2025

2007: 56 days median2008: 248 days median2009: 101 days median2010: 125 days median2012: 150 days median2013: 132 days median2014: 166 days median2015: 105 days median2017: 134 days median2018: 296 days median2019: 261 days median2020: 188 days median2021: 227 days median2022: 226 days median2023: 555 days median2024: 592 days median2025: 169 days median2026 (partial year): 224 days median
2007high 592 (2024) · low 56 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CCK

1in 2022

2008: 12009: 192010: 42011: 142012: 32013: 2, 1 Class I2015: 12018: 52019: 7, 7 Class I2020: 12022: 1
2007high 19 (2009) · low 0 (2007)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · CCK

1,259in 2025

2007: 72008: 202009: 212010: 122011: 182012: 132013: 282014: 512015: 1142016: 882017: 582018: 632019: 1412020: 2,3022021: 2,2722022: 2,4752023: 1,6372024: 1,2162025: 1,259
2007high 2,475 (2022) · low 7 (2007)2025

MAUDE reports naming product code CCK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200755607
20083248120
200931011921
20103125412
20112—1418
20127150313
201341322 (1)28
20149166051
201551051114
20162—088
20175134058
20186296563
201972617 (7)141
2020418812,302
2021422702,272
2022322612,475
2023455501,637
2024359201,216
2025316901,259
202632240—

What is it indicated for?

The Capnostream20 combined capnograph/pulse oximeter monitor is intended to provide professionally trained health care providers the continuous, non invasive measurement and monitoring of carbon dioxide concentration of the expired and inspired breath and respiration rate, and for the continuous non-invasive monitoring of functional oxygen saturation of arterial hemoglobin (SPO 2 ) and pulse rate- It is intended for use with neonatal, pediatric and adult…

Read the full statement (175 words)

The Capnostream20 combined capnograph/pulse oximeter monitor is intended to provide

professionally trained health care providers the continuous, non invasive measurement and

monitoring of carbon dioxide concentration of the expired and inspired breath and respiration

rate, and for the continuous non-invasive monitoring of functional oxygen saturation of arterial

hemoglobin (SPO 2 ) and pulse rate- It is intended for use with neonatal, pediatric and adult

patients in hospitals, hospital type facilities, intra hospital transport and home environments.

The Capnostreamn20 monitor provides the clinician with an integrated pulmonary index (IPI).

The IPI is based on four parameters provided by the monitor: end tidal carbon dioxide,

respiration rate, oxygen saturation and pulse rate. The IPI is a single index of an adult or

pediatric patient's ventilatory status displayed on a scale of 1 - 10, where 10 indicates optimal

pulmonary status. IPI monitoring displays a single value that represents the patient's pulmonary

parameters and alerts clinicians to changes in the patient's pulmonary status.

The IPI is an adjunct to, and is not intended to replace, vital sign monitoring.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K094012: CAPNOSTREAM20 with MICROMEDICO2 Module.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K094012

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026