Cleared on Mar 16, 2011 as substantially equivalent to K023785 (Philips Medical Systems (Cleveland), Inc., 2003) and 1 other predicate after an 85-day review. Its family tree reaches back 5 generations to 1993.
- Decided
- Mar 16, 2011
- Review
- 85 days
- Class
- Class II
- Product code
- LLZ
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 5 generations to K930090 (1993). 11 ancestors in all. No later device cites it as a predicate yet.
- Root · 5 generations backK930090 HelicatElscint, Inc. · 1993
- 4 generations backK961464 Select/SPElscint, Inc. · 1996 · Recalled
- 3 generations backK982060 Volumax CT Imaging SystemElscint, Inc. · 1998
- 2 generations backK012009 MX8000 Idt CT SystemMarconi Medical Systems, Inc. · 2001 · Recalled
- 1 generation backK023785 Lung Nodule Assessment and Comparison OptionPhilips Medical Systems (Cleveland), Inc. · 2003
- This deviceK103720 Synapse 3D Lung and Abdomen AnalysisFujifilm Medical Systems U.S.A, Inc. · 2011
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −5 | K930090 | Helicat | Elscint, Inc. | 1993 | — |
| −4 | K961464 | Select/SP | Elscint, Inc. | 1996 | 3 |
| −3 | K982060 | Volumax CT Imaging System | Elscint, Inc. | 1998 | — |
| −2 | K012009 | MX8000 Idt CT System | Marconi Medical Systems, Inc. | 2001 | 61 |
| −1 | K023785 | Lung Nodule Assessment and Comparison Option | Philips Medical Systems (Cleveland), Inc. | 2003 | — |
| 0 (this device) | K103720 | Synapse 3D Lung and Abdomen Analysis | Fujifilm Medical Systems U.S.A, Inc. | 2011 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1994 | 2 | 0 |
| 1995 | 1 | 0 |
| 1997 | 1 | 0 |
| 2001 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LLZ device
- #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K023785 | Lung Nodule Assessment and Comparison OptionSummary page 2…U.S.A. Inc., Synapse 3D Lung and Abdomen Analysis 510(k) Decision Date: TBD Decision: TBID Predicate Devices: *Lung Nodule Assessment and Comparison Option (K023785), Philips *Aquarius Workstation (KOl 1142), TeraRecon Description of the Device Synapse 3D Lung and Abdomen Analysis is an… | 2003 |
| * | K011142 | Aquarius Workstation | 2001 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 18 years and passes through 4 companies; a new generation was cleared every 3.0 years on median.
- 3 of the 11 ancestors have a recall of any class.
- 2 other devices also cite its predicate K023785.
How does its category compare?
All LLZ devicesLLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · LLZ
58in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LLZ
173in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LLZ
11in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LLZ
116in 2025
MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 76 | 36 | 20 | 152 |
| 2008 | 94 | 52 | 32 | 154 |
| 2009 | 70 | 62 | 21 | 145 |
| 2010 | 51 | 98 | 17 | 145 |
| 2011 | 106 | 79 | 30 | 454 |
| 2012 | 82 | 87 | 12 | 266 |
| 2013 | 95 | 84 | 64 | 1,130 |
| 2014 | 78 | 89 | 6 | 15,631 |
| 2015 | 64 | 90 | 16 | 211 |
| 2016 | 82 | 90 | 12 | 290 |
| 2017 | 78 | 107 | 5 | 104 |
| 2018 | 104 | 105 | 7 | 72 |
| 2019 | 74 | 107 | 2 | 88 |
| 2020 | 81 | 115 | 6 | 82 |
| 2021 | 83 | 116 | 3 | 70 |
| 2022 | 65 | 137 | 4 | 28 |
| 2023 | 87 | 157 | 8 | 26 |
| 2024 | 62 | 131 | 6 | 42 |
| 2025 | 58 | 173 | 11 | 116 |
| 2026 | 45 | 110 | 14 | — |
What is it indicated for?
Synapse 3D Lung and Abdomen Analysis is medical imaging software used with Synapse 3D Basic Tools that is intended to provide trained medical imaging professionals, including Physicians and Radiologists, with tools to aid them in reading, interpreting, reporting, and treatment planning. Synapse 3D Lung and Abdomen Analysis accepts DICOM compliant medical images acquired from CT. This product is not intended for use with or for the primary diagnostic…
Read the full statement (144 words)
Synapse 3D Lung and Abdomen Analysis is medical imaging software used with Synapse 3D Basic Tools that is intended to provide trained medical imaging professionals, including Physicians and Radiologists, with tools to aid them in reading, interpreting, reporting, and treatment planning. Synapse 3D Lung and Abdomen Analysis accepts DICOM compliant medical images acquired from CT.
This product is not intended for use with or for the primary diagnostic interpretation of Mammography images.
Addition to Synapse 3D Basic Tools, Synapse 3D Lung and Abdomen Analysis is intended to;
* use non-contrasted and contrast enhanced computed tomographic images of the lung, perform boundary detection and volume calculation for pulmonary nodes in the lung based on the location specified by the user and display low absorption areas.
* use non-contrasted CT images and calculate subcutaneous fat and visceral fat areas in 2D and both volumes in 3D.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K103720 · printed Nov 6, 2026
Cite this page
510(k) Report. “K103720: Synapse 3D Lung and Abdomen Analysis.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K103720