510(k) Report

510(k) · Cleared

Cleared

Lung Nodule Assessment and Comparison Option (LNA)

K162484510(k) TraditionalCleared Feb 23, 2017169-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Philips Medical Systems Nederland B.V. · LLZ System, Image Processing, Radiological

Cleared on Feb 23, 2017 as substantially equivalent to K151283 (Vital Images, Inc., 2015) and 1 other predicate after a 169-day review. Its family tree reaches back 8 generations to 1991. 7 later devices descend from it.

Decided
Feb 23, 2017
Review
169 days
Class
Class II
Product code
LLZ
Recalls
None
Predicates
2

Its longest line of descent runs back 8 generations to K913770 (1991). 34 ancestors in all. 7 later devices descend from it, 6 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2003: 1 other ancestor2001: 6 other ancestors1996: 3 other ancestors2002: 2 other ancestors1998: 3 other ancestors1993: 1 other ancestor2000: 2 other ancestors1997: 2 other ancestors1995: 1 other ancestor1994: 4 other ancestors1999: 1 other ancestor2022: 1 descendant cleared2024: 1 descendant cleared2021: 2 descendants cleared2020: 2 descendants cleared2025: 1 descendant clearedReference device: K153444 · Philips Multislice CT System with Low Dose CT Lung Cancer · Philips Medical Systems (Cleveland), Inc. · 2016Reference device: K060937 · Brilliance Volume · Philips Medical Systems (Cleveland), Inc. · 2006 · recalledReference device: K160315 · I4 (Integrated Intelligent Imaging Informatics) system · Philips Medical Systems Nederland B.V. · 2016Reference device: K111336 · EBW NM 2.0 · Philips Medical Systems (Cleveland), Inc. · 2011K913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991K960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK023003 · Imagechecker-CT Workstation · R2 Technology, Inc. · 2002×2: 2 generations cleared close together, K032748 (2003), K040305 (2004) K043333 · VITREA2, Version 3.7 Medical Image Processing System · Vital Images, Inc. · 2004 · recalledK151283 · Lung Analysis Software · Vital Images, Inc. · 20151990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 2 other ancestors3 generations back: 4 other ancestors4 generations back: 9 other ancestors5 generations back: 6 other ancestors6 generations back: 3 other ancestors7 generations back: 1 other ancestor 1 generation forward: 6 descendants2 generations forward: 1 descendant K151283 · Lung Analysis Software · Vital Images, Inc. · 2015K043333 · VITREA2, Version 3.7 Medical Image Processing System · Vital Images, Inc. · 2004 · recalledK040305 · VITREA2 Version 3.5 · Vital Images, Inc. · 2004K032748 · VITREA2, Version 3.4 Medical Image Processing Software · Vital Images, Inc. · 2003 · recalledK023003 · Imagechecker-CT Workstation · R2 Technology, Inc. · 2002K020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991−50
  1. Root · 8 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 7 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
  3. 6 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
  4. 5 generations backK023003 Imagechecker-CT WorkstationR2 Technology, Inc. · 2002
  5. 4 generations backK032748 VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc. · 2003 · Recalled
  6. 3 generations backK040305 VITREA2 Version 3.5Vital Images, Inc. · 2004
  7. 2 generations backK043333 VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc. · 2004 · Recalled
  8. 1 generation backK151283 Lung Analysis SoftwareVital Images, Inc. · 2015
  9. This deviceK162484 Lung Nodule Assessment and Comparison Option (LNA)Philips Medical Systems Nederland B.V. · 2017
  10. Descendant · cites it directly · 1 of its ownK202990 NinesMeasureNines, Inc. · 2021
  11. Descendant · cites it directly · 1 of its ownK193220 Aview LCSCoreline Soft Co., Ltd. · 2020
  12. Descendant · cites it directly · 0 of its ownK240554 InferRead Lung CT.AIInfervision Medical Technology Co., Ltd. · 2025
  13. Descendant · cites it directly · 0 of its ownK240740 qCT LN QuantQure.Ai Technologies · 2024
  14. Descendant · cites it directly · 0 of its ownK221612 ClearRead CTRiverain Technologies, Inc. · 2022

Showing 5 of 7 descendants. See all descendants

Descendants cleared per year

2020: 22021: 22022: 12024: 12025: 1
2020high 2 (2020) · low 0 (2023)2026

Most influential descendants

Showing 5 of 7 · See all
  • K202990NinesMeasureNines, Inc. · 2021 · cites it directly1descendant
  • K193220Aview LCSCoreline Soft Co., Ltd. · 2020 · cites it directly1descendant
  • K240554InferRead Lung CT.AIInfervision Medical Technology Co., Ltd. · 2025 · cites it directly0descendants
  • K240740qCT LN QuantQure.Ai Technologies · 2024 · cites it directly0descendants
  • K221612ClearRead CTRiverain Technologies, Inc. · 2022 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−7K960613GE Advantage Windows Review WorkstationGE Medical Systems1996—
−6K020483Advantage Workstation 4.1GE Medical Systems20022
−5K023003Imagechecker-CT WorkstationR2 Technology, Inc.2002—
−4K032748VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc.20032
−3K040305VITREA2 Version 3.5Vital Images, Inc.2004—
−2K043333VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc.20041
−1K151283Lung Analysis SoftwareVital Images, Inc.2015—
0 (this device)K162484Lung Nodule Assessment and Comparison Option (LNA)Philips Medical Systems Nederland B.V.2017—
+1K202990NinesMeasureNines, Inc.2021—
+1K193220Aview LCSCoreline Soft Co., Ltd.2020—
+1K240554InferRead Lung CT.AIInfervision Medical Technology Co., Ltd.2025—
+1K240740qCT LN QuantQure.Ai Technologies2024—
+1K221612ClearRead CTRiverain Technologies, Inc.2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199310
199440
199510
199630
199720
199830
199910
200020
200160
200220
200310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202020
202120
202210
202410
202510
FIG. 1 — Lineage of K162484, 1991–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K151283Lung Analysis Software
Summary page 5
…System, Image October JAK, 21CFR Class Analysis K151283 processing, Radiology…
Vital Images, Inc.2015—
*K023785Lung Nodule Assessment and Comparison Option
Summary page 5
…System, Image Assessment Feb 10 90 21CFR Class K023785 processing, Radiology and…
Philips Medical Systems (Cleveland), Inc.2003—
†K153444Philips Multislice CT System with Low Dose CT Lung CancerPhilips Medical Systems (Cleveland), Inc.2016—
†K060937Brilliance VolumePhilips Medical Systems (Cleveland), Inc.200661
†K160315I4 (Integrated Intelligent Imaging Informatics) systemPhilips Medical Systems Nederland B.V.2016—
†K111336EBW NM 2.0Philips Medical Systems (Cleveland), Inc.2011—

What descends from it? (7)

6 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K202990NinesMeasureNines, Inc.20211
K193220Aview LCSCoreline Soft Co., Ltd.20201
K240554InferRead Lung CT.AIInfervision Medical Technology Co., Ltd.20250
K240740qCT LN QuantQure.Ai Technologies20240
K221612ClearRead CTRiverain Technologies, Inc.20220
K201501VeolityMeVis Medical Solutions AG20210

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 26 years and passes through 5 companies; a new generation was cleared every 1.3 years on median.
  • 8 of the 34 ancestors have a recall of any class.
  • Of its descendants, K202990 (Nines, Inc., 2021) has gone furthest, with 1 descendant of its own.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

The Lung Nodule Assessment and Comparison Option is intended for use as a diagnostic patient-imaging tool.

It is intended for the review and analysis of thoracic CT images, providing quantitative and characterizing information

about nodules in the lung in a single study, or over the time course of several thoracic studies. Characterizations include

diameter, volume and volume over time. The system automatically performs the measurements, allowing lung nodules

and measurements to be displayed.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K162484: Lung Nodule Assessment and Comparison Option (LNA).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K162484

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026