ClearedExactech Equinoxe Cuff Tear Arthroplasty (Cta) Head
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Exactech, Inc. · KWT Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented
Cleared on May 17, 2011 as substantially equivalent to K042021 (Exactech, Inc., 2004) and 4 other predicates after a 64-day review. Its family tree reaches back 6 generations to 1980.
- Decided
- May 17, 2011
- Review
- 64 days
- Class
- Class II
- Product code
- KWT
- Recalls
- None
- Predicates
- 5
Its longest line of descent runs back 6 generations to K800494 (1980). 49 ancestors in all, the oldest K790987 (1979). No later device cites it as a predicate yet.
- Root · 6 generations backK800494 New Jersey Hemiarthroplasty Sholder ProsDepuy, Inc. · 1980
- 5 generations backK991585 Bipolar Shoulder ProsthesisBiomet, Inc. · 1999
- 4 generations backK002998 Biomet BI-Polar Shoulder SystemBiomet, Inc. · 2000 · Recalled
- 3 generations backK030710 Bio-Modular Shoulder SystemBiomet, Inc. · 2003 · Recalled
- 2 generations backK032895 BI-Angular Shoulder SystemBiomet, Inc. · 2003
- 1 generation backK042321 Mosaic Non-Modular Proximal Body and Eas Offset Modular Humeral HeadBiomet Manufacturing Corp · 2005
- This deviceK110706 Exactech Equinoxe Cuff Tear Arthroplasty (Cta) HeadExactech, Inc. · 2011
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −6 | K800494 | New Jersey Hemiarthroplasty Sholder Pros | Depuy, Inc. | 1980 | — |
| −5 | K991585 | Bipolar Shoulder Prosthesis | Biomet, Inc. | 1999 | — |
| −4 | K002998 | Biomet BI-Polar Shoulder System | Biomet, Inc. | 2000 | 1 |
| −3 | K030710 | Bio-Modular Shoulder System | Biomet, Inc. | 2003 | 1 |
| −2 | K032895 | BI-Angular Shoulder System | Biomet, Inc. | 2003 | — |
| −1 | K042321 | Mosaic Non-Modular Proximal Body and Eas Offset Modular Humeral Head | Biomet Manufacturing Corp | 2005 | — |
| 0 (this device) | K110706 | Exactech Equinoxe Cuff Tear Arthroplasty (Cta) Head | Exactech, Inc. | 2011 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1979 | 1 | 0 |
| 1980 | 1 | 0 |
| 1987 | 1 | 0 |
| 1991 | 2 | 0 |
| 1992 | 2 | 0 |
| 1993 | 1 | 0 |
| 1994 | 2 | 0 |
| 1995 | 1 | 0 |
| 1996 | 1 | 0 |
| 1998 | 2 | 0 |
| 1999 | 7 | 0 |
| 2000 | 7 | 0 |
| 2001 | 8 | 0 |
| 2002 | 2 | 0 |
| 2003 | 2 | 0 |
| 2004 | 2 | 0 |
| 2008 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KWT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KWT device
- #1 K231657 AGILON® XO Shoulder Replacement Systemscore 17.7 · 17 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (5)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K042021 | Exactech Equinoxe Shoulder SystemSummary page 1…, Product Code HSD) 111. Legally Marketed Devices to Which Substantial Equivalence Is Claimed * Exactech Equinoxe, K042021 * DePuy Global Advantage Extended Numeral Head, K000575 & K082715 " Riomet Bio-Modular EAS Head,… | 2004 |
| * | K000575 | Global Advantage Extended Humeral HeadSummary page 1…Marketed Devices to Which Substantial Equivalence Is Claimed * Exactech Equinoxe, K042021 * DePuy Global Advantage Extended Numeral Head, K000575 & K082715 " Riomet Bio-Modular EAS Head, K0307l0 & K042321 IV. Device Description The proposed Exa… | 2000 |
| * | K082715 | Depuy Global AP Cta Humeral HeadSummary page 1…evices to Which Substantial Equivalence Is Claimed * Exactech Equinoxe, K042021 * DePuy Global Advantage Extended Numeral Head, K000575 & K082715 " Riomet Bio-Modular EAS Head, K0307l0 & K042321 IV. Device Description The proposed Exactech Equi… | 2008 |
| * | K030710 | Bio-Modular Shoulder System | 2003 |
| * | K042321 | Mosaic Non-Modular Proximal Body and Eas Offset Modular Humeral HeadSummary page 1…* Exactech Equinoxe, K042021 * DePuy Global Advantage Extended Numeral Head, K000575 & K082715 " Riomet Bio-Modular EAS Head, K0307l0 & K042321 IV. Device Description The proposed Exactech Equinoxe CTA Humeral Head devices are humeral heads for use… | 2005 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 31 years and passes through 4 companies; a new generation was cleared every 2.7 years on median.
- 8 of the 49 ancestors have a recall of any class.
- 13 other devices also cite its predicate K042021.
How does its category compare?
All KWT devicesKWT Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · KWT
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KWT
242in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KWT
1in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KWT
749in 2025
MAUDE reports naming product code KWT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 32 |
| 2008 | 0 | — | 1 | 48 |
| 2009 | 0 | — | 0 | 58 |
| 2010 | 1 | — | 7 | 71 |
| 2011 | 5 | 165 | 0 | 112 |
| 2012 | 1 | — | 2 | 83 |
| 2013 | 1 | — | 1 | 113 |
| 2014 | 1 | — | 0 | 168 |
| 2015 | 2 | — | 0 | 176 |
| 2016 | 2 | — | 1 | 445 |
| 2017 | 1 | — | 1 | 560 |
| 2018 | 2 | — | 1 | 480 |
| 2019 | 4 | 91 | 3 | 419 |
| 2020 | 1 | — | 0 | 215 |
| 2021 | 1 | — | 0 | 228 |
| 2022 | 1 | — | 0 | 273 |
| 2023 | 1 | — | 1 | 361 |
| 2024 | 1 | — | 0 | 601 |
| 2025 | 4 | 242 | 0 | 749 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
The Equinoxe Shoulder System is indicated for use in skeletally mature individuals with degenerative diseases or fractures of the glenohumeral joint where total or hemi-arthroplasty is determined by the surgeon to be the preferred method of treatment. The cemented primary humeral stem, long/revision stem, fracture stems and all Equinoxe glenoids are intended for cemented fixation. The press-fit humeral stems are intended for press-fit applications but…
Read the full statement (394 words)
The Equinoxe Shoulder System is indicated for use in skeletally mature individuals with degenerative diseases or fractures of the glenohumeral joint where total or hemi-arthroplasty is determined by the surgeon to be the preferred method of treatment.
The cemented primary humeral stem, long/revision stem, fracture stems and all Equinoxe glenoids are intended for cemented fixation.
The press-fit humeral stems are intended for press-fit applications but may be used with bone cement at the discretion the surgeon.
The reverse humeral components are intended to be used in cemented applications or in revision cases when the humeral component is well-fixed/stable, as deemed by the orthopaedic surgeon.
Humeral Heads are intended for use in cemented and press-fit applications.
Clinical indications for the PRIMARY (P), LONG (L) and FRACTURE (F) humeral components are as follows:
rheumatoid arthritis, osteoarthritis, osteonecrosis or post-traumatic degenerative problems
congenital abnormalities in the skeletally mature
primary and secondary necrosis of the humeral head.
humeral head fracture with displacement of the tuberosities
pathologies where arthrodesis or resectional arthroplasty of the humeral head are not acceptable
revisions of humeral prostheses when other treatments or devices have failed (where adequate fixation can be achieved)
displaced three-part and four-part upper humeral fractures
spiral and other fractures of the mid-humerus (in combination with glenohumeral degenerative diseases)
revision of failed previous reconstructions when distal anchorage is required
to restore mobility from previous procedures (e.g. previous fusion)
rotator cuff tear arthropathy
The Equinoxe Reverse Shoulder System, is indicated for use in skeletally mature individuals with degenerative diseases of the glenohumeral joint and a grossly deficient, irreparable rotator cuff. The Equinoxe Reverse Shoulder is also indicated for a failed glenohumeral joint replacement with loss of rotator cuff function resulting in superior migration of the humeral head.
The Equinoxe Platform Fracture Stem is indicated for use in skeletally mature individuals with acute fracture of the proximal humerus and displacement of the tuberosities, displaced 3- and 4-part fractures of the proximal humerus (hemi-arthroplasty), or acute fracture of the proximal humerus with failure of the glenohumeral joint (primary total shoulder arthroplasty). The Equinoxe Platform Fracture Stem is also indicated for acute fracture of the proximal humerus in combination with degenerative diseases of the glenohumeral joint and a grossly deficient, irreparable rotator cuff resulting in superior migration of the humeral head (reverse total shoulder arthroplasty). The Equinoxe Platform Fracture Stem is indicated for cemented use only.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K110706 · printed Nov 3, 2026
Cite this page
510(k) Report. “K110706: Exactech Equinoxe Cuff Tear Arthroplasty (Cta) Head.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K110706
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026