510(k) · Cleared
ClearedImagelink
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Computer Programs and Systems, Inc. · LLZ System, Image Processing, Radiological
Cleared on Sep 30, 2011 as substantially equivalent to K043415 (Ge Medical Systems Information Technologies, 2005) after a 70-day review. Its family tree reaches back 5 generations to 1991.
- Decided
- Sep 30, 2011
- Review
- 70 days
- Class
- Class II
- Product code
- LLZ
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 5 generations to K913770 (1991). 9 ancestors in all. No later device cites it as a predicate yet.
- Root · 5 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
- 4 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
- 3 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
- 2 generations backK033400 Seno AdvantageGe Medical Systems W-400 · 2003 · Recalled
- 1 generation backK043415 Centricity Pacs SystemGe Medical Systems Information Technologies · 2005 · Recalled
- This deviceK112096 ImagelinkComputer Programs and Systems, Inc. · 2011
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −5 | K913770 | Advantage V.S. CT/MR Rad Diagnostic Workstation | General Electric Co. | 1991 | — |
| −4 | K960613 | GE Advantage Windows Review Workstation | GE Medical Systems | 1996 | — |
| −3 | K020483 | Advantage Workstation 4.1 | GE Medical Systems | 2002 | 2 |
| −2 | K033400 | Seno Advantage | Ge Medical Systems W-400 | 2003 | 6 |
| −1 | K043415 | Centricity Pacs System | Ge Medical Systems Information Technologies | 2005 | 23 |
| 0 (this device) | K112096 | Imagelink | Computer Programs and Systems, Inc. | 2011 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1992 | 1 | 0 |
| 1994 | 1 | 0 |
| 1998 | 1 | 0 |
| 2002 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LLZ device
- #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K043415 | Centricity Pacs SystemSummary page 1…21 CFR 892.2050 F.6 Predicate Device The legally marketed device to which CPSI claims equivalence is found in 510(k) number K043415 and is called Centricity PACS System, manufactured by GE Medical Systems, Information Technologies. 07/19/2011… | 2005 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 20 years and passes through 5 companies; a new generation was cleared every 4.3 years on median.
- 3 of the 9 ancestors have a recall of any class.
- 10 other devices also cite its predicate K043415.
How does its category compare?
All LLZ devicesLLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · LLZ
58in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LLZ
173in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LLZ
11in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LLZ
116in 2025
MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 76 | 36 | 20 | 152 |
| 2008 | 94 | 52 | 32 | 154 |
| 2009 | 70 | 62 | 21 | 145 |
| 2010 | 51 | 98 | 17 | 145 |
| 2011 | 106 | 79 | 30 | 454 |
| 2012 | 82 | 87 | 12 | 266 |
| 2013 | 95 | 84 | 64 | 1,130 |
| 2014 | 78 | 89 | 6 | 15,631 |
| 2015 | 64 | 90 | 16 | 211 |
| 2016 | 82 | 90 | 12 | 290 |
| 2017 | 78 | 107 | 5 | 104 |
| 2018 | 104 | 105 | 7 | 72 |
| 2019 | 74 | 107 | 2 | 88 |
| 2020 | 81 | 115 | 6 | 82 |
| 2021 | 83 | 116 | 3 | 70 |
| 2022 | 65 | 137 | 4 | 28 |
| 2023 | 87 | 157 | 8 | 26 |
| 2024 | 62 | 131 | 6 | 42 |
| 2025 | 58 | 173 | 11 | 116 |
| 2026 | 45 | 110 | 14 | — |
What is it indicated for?
ImageLink TM is an integrated medical imaging solutionthat allows for the storage,
manipulation, and annotation of high resolution digital radiological images from multiple
source modalities. It enhances the efficiency of diagnostic decision making and includes a
feature-rich viewer with customizable worklists and hanging protocols that can be
organized to meet the unique requirements and style of the individual radiologist.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K112096 · printed Nov 4, 2026
Cite this page
510(k) Report. “K112096: Imagelink.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K112096
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026