510(k) Report

510(k) · Cleared

Recalled · 2011

Isite Pacs, V 4. X

K063267510(k) TraditionalCleared Nov 9, 200610-day reviewClass II21 CFR 892.2050Recalls 4

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Stentor Inc., A Philips Medical Systems Co. · LLZ System, Image Processing, Radiological

Cleared on Nov 9, 2006 as substantially equivalent to K043415 (Ge Medical Systems Information Technologies, 2005) and 2 other predicates after a 10-day review. Its family tree reaches back 5 generations to 1991. 8 later devices descend from it. It has been recalled 4 times.

Decided
Nov 9, 2006
Review
10 days
Class
Class II
Product code
LLZ
Recalls
4
Predicates
3

Its longest line of descent runs back 5 generations to K913770 (1991). 12 ancestors in all. 8 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2006: 1 other ancestor2004: 1 other ancestor2003: 1 other ancestor2002: 1 other ancestor1998: 1 other ancestor1992: 1 other ancestor1994: 1 other ancestor2009: 1 descendant cleared2011: 1 descendant cleared2012: 1 descendant cleared2016: 1 descendant cleared2018: 2 descendants cleared2025: 1 descendant cleared2026: 1 descendant clearedK913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991K960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK033400 · Seno Advantage · Ge Medical Systems W-400 · 2003 · recalledK043415 · Centricity Pacs System · Ge Medical Systems Information Technologies · 2005 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 2 other ancestors3 generations back: 2 other ancestors5 generations back: 1 other ancestor 1 generation forward: 3 descendants2 generations forward: 2 descendants3 generations forward: 1 descendant4 generations forward: 1 descendant5 generations forward: 1 descendant K043415 · Centricity Pacs System · Ge Medical Systems Information Technologies · 2005 · recalledK033400 · Seno Advantage · Ge Medical Systems W-400 · 2003 · recalledK020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991−50+5
  1. Root · 5 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 4 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
  3. 3 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
  4. 2 generations backK033400 Seno AdvantageGe Medical Systems W-400 · 2003 · Recalled
  5. 1 generation backK043415 Centricity Pacs SystemGe Medical Systems Information Technologies · 2005 · Recalled
  6. This deviceK063267 Isite Pacs, V 4. XStentor Inc., A Philips Medical Systems Co. · 2006
  7. Descendant · cites it directly · 5 of its ownK111804 Intellispace Pacs 4.XPhilips Healthcare Informatics, Inc. · 2011 · Recalled
  8. Descendant · 2 generations on · 3 of its ownK160315 I4 (Integrated Intelligent Imaging Informatics) systemPhilips Medical Systems Nederland B.V. · 2016
  9. Descendant · 3 generations on · 2 of its ownK173588 Illumeo SystemPhilips Medical Systems Technologies, Ltd. · 2018
  10. Descendant · 4 generations on · 1 of its ownK250181 AV ViewerPhilips Medical Systems Nederland B.V. · 2025
  11. Descendant · 5 generations on · 0 of its ownK261465 Indira Cloud ViewerIndigo Technologies · 2026

Showing 5 of 8 descendants. See all descendants

Descendants cleared per year

2009: 12011: 12012: 12016: 12018: 22025: 12026: 1
2009high 2 (2018) · low 0 (2010)2026

Most influential descendants

Showing 5 of 8 · See all
  • K111804Intellispace Pacs 4.XPhilips Healthcare Informatics, Inc. · 2011 · cites it directly5descendants
  • K160315I4 (Integrated Intelligent Imaging Informatics) systemPhilips Medical Systems Nederland B.V. · 2016 · 2 generations on3descendants
  • K173588Illumeo SystemPhilips Medical Systems Technologies, Ltd. · 2018 · 3 generations on2descendants
  • K250181AV ViewerPhilips Medical Systems Nederland B.V. · 2025 · 4 generations on1descendant
  • K261465Indira Cloud ViewerIndigo Technologies · 2026 · 5 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−4K960613GE Advantage Windows Review WorkstationGE Medical Systems1996—
−3K020483Advantage Workstation 4.1GE Medical Systems20022
−2K033400Seno AdvantageGe Medical Systems W-40020036
−1K043415Centricity Pacs SystemGe Medical Systems Information Technologies200523
0 (this device)K063267Isite Pacs, V 4. XStentor Inc., A Philips Medical Systems Co.2006—
+1K111804Intellispace Pacs 4.XPhilips Healthcare Informatics, Inc.20112
+2K160315I4 (Integrated Intelligent Imaging Informatics) systemPhilips Medical Systems Nederland B.V.2016—
+3K173588Illumeo SystemPhilips Medical Systems Technologies, Ltd.2018—
+4K250181AV ViewerPhilips Medical Systems Nederland B.V.2025—
+5K261465Indira Cloud ViewerIndigo Technologies2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199210
199410
199810
200210
200310
200410
200610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201110
201210
201610
201820
202510
202610
FIG. 1 — Lineage of K063267, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K043415Centricity Pacs System
Summary page 1
…Code: LLZ 1.5 Substantial Equivalence Manufacturer: General Electric Medical Systems Model: GE Centricity PACS 510(k) Number: K043415 Manufacturer: Eastman Kodak Company Model: Kodak PACS 510(k) Number: K060055 Manufacturer: Sten…
Ge Medical Systems Information Technologies200523
*K060055Kodak Pacs
Summary page 1
…al Systems Model: GE Centricity PACS 510(k) Number: K043415 Manufacturer: Eastman Kodak Company Model: Kodak PACS 510(k) Number: K060055 Manufacturer: Stentor, Inc. Model: iSite PACS 3.3 510(k) Number: K042292…
Eastman Kodak Company2006—
*K042292Isite Pacs
Summary page 1
…Eastman Kodak Company Model: Kodak PACS 510(k) Number: K060055 Manufacturer: Stentor, Inc. Model: iSite PACS 3.3 510(k) Number: K042292 /t Philips Company Confidential Page 1 of 2…
Stentor, Inc.20047

Also cleared against K043415: 10 other devices →

What descends from it? (8)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K111804Intellispace Pacs 4.XPhilips Healthcare Informatics, Inc.20115
K120305Thinkingnet, Thinkingpacs/Ris - Proprietary Name Fro Thinkingnet, Thinkingarchive (or…Thinking Systems Corp.20120
K083740Mammodiagnost VUPhilips Medical Systems Nederland B.V.20090

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Feb 23, 2011Not classifiedZ-1881-2011Software designA software anomaly that occurs when clinicians use Volume Vision to view images in 3D and uses the measurement tool to measure regions of interest. This could lead to an incorrect interpretation of the measurements which could cause an…
Dec 29, 2008Not classifiedZ-0948-2009Software designProduct may display clinical reports with the study date and time in GMT format, which may not be obvious to the end user, who may expect to see the local time in the report.
Aug 29, 2008Not classifiedZ-0118-2009Software designTwo defects have been identified: 1) potential to display a patient on the canvas page that is different from the patient whose images are displayed on diagnostic monitors when using Conference Presentation States and when opening two or…
Jan 29, 2008Not classifiedZ-1444-2008Software designWhen using the Freehand Region of Interest (ROI) tool, errors may occur in area calculation yielding incorrect results. The firm discovered that a descrepancy exists in the measurement provided by the tool.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 15 years and passes through 5 companies; a new generation was cleared every 1.8 years on median.
  • 4 of the 12 ancestors have a recall of any class.
  • Of its descendants, K111804 (Philips Healthcare Informatics, Inc., 2011) has gone furthest, with 5 descendants of its own.
  • 10 other devices also cite its predicate K043415.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

iSite PACS is an image management system intended to be used by trained professionals, including but not limited to physicians, nurses and medical technicians. The system is a software package used with general purpose computing hardware to acquire, store, distribute, process and display images and associated data throughout a clinical environment. The software performs digital image processing, measurement, communication and storage. Lossy compressed…

Read the full statement (106 words)

iSite PACS is an image management system intended to be used by trained professionals, including but not limited to physicians, nurses and medical technicians.

The system is a software package used with general purpose computing hardware to acquire, store, distribute, process and display images and associated data throughout a clinical environment. The software performs digital image processing, measurement, communication and storage.

Lossy compressed mammographic images and digitized film screen images must not be reviewed for primary image interpretations.

Mammographic images may only be interpreted using an FDA approved monitor that offers at least 5 Mpixel resolution and meets other technical specifications reviewed and accepted by FDA.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K063267: Isite Pacs, V 4. X.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K063267

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026