Vantage Titan 3T

K152371510(k) TraditionalCleared Oct 23, 201563-day reviewClass II21 CFR 892.1000Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Toshibamedical Systems Corporation · LNH System, Nuclear Magnetic Resonance Imaging

Cleared on Oct 23, 2015 as substantially equivalent to K143008 (Toshibamedical Systems Corporation, 2015) after a 63-day review. Its family tree reaches back 11 generations to 2000. 32 later devices descend from it. It has been recalled once.

Decided
Oct 23, 2015
Review
63 days
Class
Class II
Product code
LNH
Recalls
1
Predicates
1

Its longest line of descent runs back 11 generations to K002531 (2000). 32 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2017: 2 descendants cleared2016: 1 descendant cleared2018: 3 descendants cleared2020: 6 descendants cleared2019: 2 descendants cleared2021: 8 descendants cleared2022: 4 descendants cleared2023: 1 descendant cleared2024: 2 descendants cleared2025: 2 descendants cleared2026: 1 descendant clearedK002531 · Excelart with Pianissimo, Model MRT-1501/P3 · Toshiba America Mri, Inc. · 2000 · recalledK023511 · Excelart with Pianissimo XG/AG Spin Edition, Model MRT-1501/P3, P2 · Toshiba America Medical Systems, In.C · 2002 · recalledK032490 · Toshiba Excelart Vantage XGV/Agv Mri Diagnostic System, Models MRT-1503/P3 and MRT-1503/P2 · Toshiba America Medical Systems, In.C · 2003 · recalledK060003 · Excelart Vantage ZGV · Toshibamedical Systems Corporation · 2006 · recalledK063361 · Excelart Vantage Atlas, Model MRT-1503 · Toshiba America Medical Systems, In.C · 2006 · recalledK080038 · Vantage Titan, Model MRT-1504/S3 · Toshiba America Medical Systems, In.C · 2008 · recalledK102489 · Vantage Titan 3T · Toshiba Medical Systems Corporation, Japan · 2011 · recalledK113093 · Vantage Titan 3T · Toshibamedical Systems Corporation · 2012 · recalledK120487 · Vantage Titan 3T · Toshibamedical Systems Corporation · 2012K132160 · Vantage Titan 3T · Toshibamedical Systems Corporation · 2013K143008 · Vantage Titan 3T · Toshibamedical Systems Corporation · 2015200020052010201520202025
Descendants, by generation 1 generation forward: 2 descendants2 generations forward: 2 descendants3 generations forward: 2 descendants4 generations forward: 5 descendants5 generations forward: 5 descendants6 generations forward: 5 descendants7 generations forward: 2 descendants8 generations forward: 2 descendants9 generations forward: 2 descendants10 generations forward: 2 descendants11 generations forward: 2 descendants12 generations forward: 1 descendant K143008 · Vantage Titan 3T · Toshibamedical Systems Corporation · 2015K132160 · Vantage Titan 3T · Toshibamedical Systems Corporation · 2013K120487 · Vantage Titan 3T · Toshibamedical Systems Corporation · 2012K113093 · Vantage Titan 3T · Toshibamedical Systems Corporation · 2012 · recalledK102489 · Vantage Titan 3T · Toshiba Medical Systems Corporation, Japan · 2011 · recalledK080038 · Vantage Titan, Model MRT-1504/S3 · Toshiba America Medical Systems, In.C · 2008 · recalledK063361 · Excelart Vantage Atlas, Model MRT-1503 · Toshiba America Medical Systems, In.C · 2006 · recalledK060003 · Excelart Vantage ZGV · Toshibamedical Systems Corporation · 2006 · recalledK032490 · Toshiba Excelart Vantage XGV/Agv Mri Diagnostic System, Models MRT-1503/P3 and MRT-1503/P2 · Toshiba America Medical Systems, In.C · 2003 · recalledK023511 · Excelart with Pianissimo XG/AG Spin Edition, Model MRT-1501/P3, P2 · Toshiba America Medical Systems, In.C · 2002 · recalledK002531 · Excelart with Pianissimo, Model MRT-1501/P3 · Toshiba America Mri, Inc. · 2000 · recalled−10−50+5+10
  1. Root · 11 generations backK002531 Excelart with Pianissimo, Model MRT-1501/P3Toshiba America Mri, Inc. · 2000 · Recalled
  2. 7 generations between
  3. 3 generations backK120487 Vantage Titan 3TToshibamedical Systems Corporation · 2012
  4. 2 generations backK132160 Vantage Titan 3TToshibamedical Systems Corporation · 2013
  5. 1 generation backK143008 Vantage Titan 3TToshibamedical Systems Corporation · 2015
  6. This deviceK152371 Vantage Titan 3TToshibamedical Systems Corporation · 2015
  7. Descendant · cites it directly · 31 of its ownK162183 Vantage Galan 3T, MRT-3020, V4.0Toshibamedical Systems Corporation · 2016
  8. Descendant · 2 generations on · 16 of its ownK170412 Vantage Titan 1.5T, MRT-1510, M-Power GXToshibamedical Systems Corporation · 2017 · Recalled
  9. Descendant · 3 generations on · 14 of its ownK182282 Vantage Orian 1.5T, MRT-1550, V4.5Canon Medical Systems Corporation · 2018
  10. Descendant · 2 generations on · 13 of its ownK173382 Vantage Galan 3T, V4.6Toshibamedical Systems Corporation · 2018
  11. Descendant · 4 generations on · 12 of its ownK193021 Vantage Orian 1.5T, MRT-1550, V6.0Canon Medical Systems Corporation · 2020
Show all 11 generations
  1. Root · 11 generations backK002531 Excelart with Pianissimo, Model MRT-1501/P3Toshiba America Mri, Inc. · 2000 · Recalled
  2. 10 generations backK023511 Excelart with Pianissimo XG/AG Spin Edition, Model MRT-1501/P3, P2Toshiba America Medical Systems, In.C · 2002 · Recalled
  3. 9 generations backK032490 Toshiba Excelart Vantage XGV/Agv Mri Diagnostic System, Models…Toshiba America Medical Systems, In.C · 2003 · Recalled
  4. 8 generations backK060003 Excelart Vantage ZGVToshibamedical Systems Corporation · 2006 · Recalled
  5. 7 generations backK063361 Excelart Vantage Atlas, Model MRT-1503Toshiba America Medical Systems, In.C · 2006 · Recalled
  6. 6 generations backK080038 Vantage Titan, Model MRT-1504/S3Toshiba America Medical Systems, In.C · 2008 · Recalled
  7. 5 generations backK102489 Vantage Titan 3TToshiba Medical Systems Corporation, Japan · 2011 · Recalled
  8. 4 generations backK113093 Vantage Titan 3TToshibamedical Systems Corporation · 2012 · Recalled
  9. 3 generations backK120487 Vantage Titan 3TToshibamedical Systems Corporation · 2012
  10. 2 generations backK132160 Vantage Titan 3TToshibamedical Systems Corporation · 2013
  11. 1 generation backK143008 Vantage Titan 3TToshibamedical Systems Corporation · 2015
  12. This deviceK152371 Vantage Titan 3TToshibamedical Systems Corporation · 2015

Showing 5 of 32 descendants. See all descendants

Descendants cleared per year

2016: 12017: 22018: 32019: 22020: 62021: 82022: 42023: 12024: 22025: 22026: 1
2016high 8 (2021) · low 1 (2016)2026

Most influential descendants

Showing 5 of 32 · See all
  • K162183Vantage Galan 3T, MRT-3020, V4.0Toshibamedical Systems Corporation · 2016 · cites it directly31descendants
  • K170412Vantage Titan 1.5T, MRT-1510, M-Power GXToshibamedical Systems Corporation · 2017 · 2 generations on16descendants
  • K182282Vantage Orian 1.5T, MRT-1550, V4.5Canon Medical Systems Corporation · 2018 · 3 generations on14descendants
  • K173382Vantage Galan 3T, V4.6Toshibamedical Systems Corporation · 2018 · 2 generations on13descendants
  • K193021Vantage Orian 1.5T, MRT-1550, V6.0Canon Medical Systems Corporation · 2020 · 4 generations on12descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−11K002531Excelart with Pianissimo, Model MRT-1501/P3Toshiba America Mri, Inc.20004
−10K023511Excelart with Pianissimo XG/AG Spin Edition, Model MRT-1501/P3, P2Toshiba America Medical Systems, In.C20022
−9K032490Toshiba Excelart Vantage XGV/Agv Mri Diagnostic System, Models MRT-1503/P3 and…Toshiba America Medical Systems, In.C20033
−8K060003Excelart Vantage ZGVToshibamedical Systems Corporation20061
−7K063361Excelart Vantage Atlas, Model MRT-1503Toshiba America Medical Systems, In.C20061
−6K080038Vantage Titan, Model MRT-1504/S3Toshiba America Medical Systems, In.C20082
−5K102489Vantage Titan 3TToshiba Medical Systems Corporation, Japan20111
−4K113093Vantage Titan 3TToshibamedical Systems Corporation20121
−3K120487Vantage Titan 3TToshibamedical Systems Corporation2012—
−2K132160Vantage Titan 3TToshibamedical Systems Corporation2013—
−1K143008Vantage Titan 3TToshibamedical Systems Corporation2015—
0 (this device)K152371Vantage Titan 3TToshibamedical Systems Corporation2015—
+1K162183Vantage Galan 3T, MRT-3020, V4.0Toshibamedical Systems Corporation2016—
+2K170412Vantage Titan 1.5T, MRT-1510, M-Power GXToshibamedical Systems Corporation20172
+3K182282Vantage Orian 1.5T, MRT-1550, V4.5Canon Medical Systems Corporation2018—
+2K173382Vantage Galan 3T, V4.6Toshibamedical Systems Corporation2018—
+4K193021Vantage Orian 1.5T, MRT-1550, V6.0Canon Medical Systems Corporation2020—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201610
201720
201830
201920
202060
202180
202240
202310
202420
202520
202610
FIG. 1 — Lineage of K152371, 2000–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LNH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LNH device

  1. #1 K213693 MAGNETOM Vida with syngo MR XA50Ascore 23.0 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K143008Vantage Titan 3T
Summary page 5
…, MRT-3010, V3.50 SOFTWARE 7. DEVICE DESCRIPTION: The Vantage Titan 3T (Model MRT-3010) is a 3 Tesla Magnetic Resonance Imaging (MRI) System and was cleared under K143008. This submission will include the following software functionalities: UTE (Ultra Short TE), MP-RAGE, T2:mEcho, T2*:mEcho, I…
Toshibamedical Systems Corporation2015—

Also cleared against K143008: 2 other devices →

What descends from it? (32)

See all 32

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K162183Vantage Galan 3T, MRT-3020, V4.0Toshibamedical Systems Corporation201631
K172878Vantage Titan 3T, MRT-3010/A7, M-Power GXToshiba Medical Systems Corporation, Japan20170

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 14, 2016Class IIZ-2135-2016Device DesignA potential problem associated to the gradient coil (ASGC) in the Titan 3T MRI System.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 15 years and passes through 4 companies; a new generation was cleared every 1.2 years on median.
  • 8 of the 11 ancestors have a recall of any class.
  • Of its descendants, K162183 (Toshibamedical Systems Corporation, 2016) has gone furthest, with 31 descendants of its own.
  • 2 other devices also cite its predicate K143008.

How does its category compare?

All LNH devices

LNH System, Nuclear Magnetic Resonance Imaging: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · LNH

26in 2025

2007: 122008: 192009: 172010: 122011: 162012: 222013: 192014: 172015: 192016: 202017: 182018: 292019: 262020: 322021: 272022: 302023: 302024: 262025: 262026 (partial year): 24
2007high 32 (2020) · low 12 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LNH

122in 2025

2007: 35 days median2008: 53 days median2009: 70 days median2010: 94 days median2011: 81 days median2012: 89 days median2013: 108 days median2014: 108 days median2015: 140 days median2016: 108 days median2017: 98 days median2018: 128 days median2019: 62 days median2020: 121 days median2021: 87 days median2022: 74 days median2023: 124 days median2024: 104 days median2025: 122 days median2026 (partial year): 126 days median
2007high 140 (2015) · low 35 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LNH

8in 2025

2007: 252008: 122009: 72010: 172011: 112012: 52013: 22014: 132015: 12, 2 Class I2016: 12018: 712019: 52020: 42021: 412022: 132023: 10, 1 Class I2024: 42025: 8, 5 Class I2026 (partial year): 43
2007high 71 (2018) · low 0 (2017)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · LNH

1,263in 2025

2007: 1142008: 1672009: 1942010: 1652011: 1822012: 1702013: 1072014: 1192015: 1132016: 1352017: 1212018: 1582019: 1582020: 982021: 842022: 1382023: 1592024: 2812025: 1,263
2007high 1,263 (2025) · low 84 (2021)2025

MAUDE reports naming product code LNH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007123525114
2008195312167
200917707194
2010129417165
2011168111182
201222895170
2013191082107
20141710813119
20151914012 (2)113
2016201081135
201718980121
20182912871158
201926625158
202032121498
202127874184
2022307413138
20233012410 (1)159
2024261044281
2025261228 (5)1,263
20262412643—

What is it indicated for?

Vantage Titan 3T systems are indicated for use as a diagnostic imaging modality that produces cross-sectional transaxial, coronal, sagittal, and oblique images that display anatomic structures of the head or body. Additionally, this system is capable of non-contrast enhanced imaging, such as MRA. MRI (magnetic resonance imaging) images correspond to the spatial distribution of protons (hydrogen nuclei) that exhibit nuclear magnetic resonance (NMR). The…

Read the full statement (122 words)

Vantage Titan 3T systems are indicated for use as a diagnostic imaging modality that produces cross-sectional transaxial, coronal, sagittal, and oblique images that display anatomic structures of the head or body. Additionally, this system is capable of non-contrast enhanced imaging, such as MRA.

MRI (magnetic resonance imaging) images correspond to the spatial distribution of protons (hydrogen nuclei) that exhibit nuclear magnetic resonance (NMR). The NMR properties of body tissues and fluids are:

• Proton density (PD) (also called hydrogen density)

• Spin-lattice relaxation time (T1)

• Spin-spin relaxation time (T2)

• Flow dynamics

• Chemical Shift

Contrast agent use is restricted to the approved drug indications. When interpreted by a trained physician, these images yield information that can be useful in diagnosis.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K152371: Vantage Titan 3T.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K152371

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026