STERIZONE Sterilizer

K153689510(k) TraditionalCleared Jun 30, 2016190-day reviewClass II21 CFR 880.6860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Tso3, Inc. · PJJ Two Or More Sterilant Sterilizer

Cleared on Jun 30, 2016 as substantially equivalent to K141163 (Tso3, Inc., 2014) and 1 other predicate after a 190-day review. Its family tree reaches back 9 generations to 2003. 2 later devices descend from it.

Decided
Jun 30, 2016
Review
190 days
Class
Class II
Product code
PJJ
Recalls
None
Predicates
2

Its longest line of descent runs back 9 generations to K020875 (2003). 19 ancestors in all, the oldest K981625 (1999). 2 later devices descend from it, 1 citing it directly.

  1. Root · 9 generations backK020875 TSO3 Ozone Sterilizer, Model 125LTechnologies of Sterilization With Oxone, Tso3, Inc. · 2003
  2. 5 generations between
  3. 3 generations backK131120 Amsco V-Pro 1 Low, V-Pro 1 Plus, V-Pro Max Low Temperature…STERIS Corporation · 2013
  4. 2 generations backK141163 Sterizone SterilizerTso3, Inc. · 2014
  5. 1 generation backK153392 STERIZONE VP4 SterilizerTs03, Inc. · 2016
  6. This deviceK153689 STERIZONE SterilizerTso3, Inc. · 2016
  7. Descendant · cites it directly · 1 of its ownK173694 STERIZONE VP4 SterilizerTso3, Inc. · 2018
  8. Descendant · 2 generations on · 0 of its ownK190260 STERIZONE (R) VP4 SterilizerTso3, Inc. · 2019
Show all 9 generations
  1. Root · 9 generations backK020875 TSO3 Ozone Sterilizer, Model 125LTechnologies of Sterilization With Oxone, Tso3, Inc. · 2003
  2. 8 generations backK051595 TSO3 Ozone Sterilizer, Model 125LTso3, Inc. · 2006
  3. 7 generations backK090636 TSO3 Ozone Sterilizer, Model 125LTso3, Inc. · 2009
  4. 6 generations backK102330 Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation · 2011
  5. 5 generations backK112760 Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation · 2011
  6. 4 generations backK120632 Amsco V-Pro 1 Low/Plus/Max Temperature Sterilization SystemSTERIS Corporation · 2012
  7. 3 generations backK131120 Amsco V-Pro 1 Low, V-Pro 1 Plus, V-Pro Max Low Temperature…STERIS Corporation · 2013
  8. 2 generations backK141163 Sterizone SterilizerTso3, Inc. · 2014
  9. 1 generation backK153392 STERIZONE VP4 SterilizerTs03, Inc. · 2016
  10. This deviceK153689 STERIZONE SterilizerTso3, Inc. · 2016

Most influential descendants

Showing 2 of 2 · See all
  • K173694STERIZONE VP4 SterilizerTso3, Inc. · 2018 · cites it directly1descendant
  • K190260STERIZONE (R) VP4 SterilizerTso3, Inc. · 2019 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−9K020875TSO3 Ozone Sterilizer, Model 125LTechnologies of Sterilization With Oxone, Tso3, Inc.2003—
−8K051595TSO3 Ozone Sterilizer, Model 125LTso3, Inc.2006—
−7K090636TSO3 Ozone Sterilizer, Model 125LTso3, Inc.2009—
−6K102330Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation2011—
−5K112760Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation2011—
−4K120632Amsco V-Pro 1 Low/Plus/Max Temperature Sterilization SystemSTERIS Corporation2012—
−3K131120Amsco V-Pro 1 Low, V-Pro 1 Plus, V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation2013—
−2K141163Sterizone SterilizerTso3, Inc.2014—
−1K153392STERIZONE VP4 SterilizerTs03, Inc.2016—
0 (this device)K153689STERIZONE SterilizerTso3, Inc.2016—
+1K173694STERIZONE VP4 SterilizerTso3, Inc.2018—
+2K190260STERIZONE (R) VP4 SterilizerTso3, Inc.2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199910
200010
200310
200510
200720
200910
201120
201210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
201910
FIG. 1 — Lineage of K153689, 2003–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PJJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K141163Sterizone Sterilizer
Summary page 5
…ne Oxide Gas Sterilizer Class II (as per 21CFR, part 880.6860 equivalent device) Product Code: PJJ Legally Marketed Equivalent Device Name(s) STERIZONE® VP4 Sterilizer (K141163 and K153392) Page 1…
Tso3, Inc.2014—
*K153392STERIZONE VP4 Sterilizer
Cleared while this submission was under review
Summary page 5
…Sterilizer Class II (as per 21CFR, part 880.6860 equivalent device) Product Code: PJJ Legally Marketed Equivalent Device Name(s) STERIZONE® VP4 Sterilizer (K141163 and K153392) Page 1…
Ts03, Inc.2016—

Also cleared against K141163: 2 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K173694STERIZONE VP4 SterilizerTso3, Inc.20181

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 13 years and passes through 4 companies; a new generation was cleared every 1.3 years on median.
  • 8 of the 19 ancestors have a recall of any class.
  • Of its descendants, K173694 (Tso3, Inc., 2018) has gone furthest, with 1 descendant of its own.
  • 2 other devices also cite its predicate K141163.

How does its category compare?

All PJJ devices

PJJ Two Or More Sterilant Sterilizer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · PJJ

1in 2019

2014: 12016: 22018: 22019: 1
2007high 2 (2016) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PJJ

Too few PJJ 510(k)s in any year since 2007 to give a median.

Recalls per year · PJJ

No recall names PJJ since 2007.

Adverse event reports per year · PJJ

6in 2017

2017: 6
2007high 6 (2017) · low 0 (2007)2025

MAUDE reports naming product code PJJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20141—00
20150—00
20162—00
20170—06
20182—00
20191—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The STERIZONE® VP4 Sterilizer is intended for use in terminal sterilization of cleaned, rinsed, and dried metal and non-metal reusable medical devices in health care facilities. The single pre-set cycle of the STERIZONE® VP4 Sterilizer uses hydrogen peroxide and ozone. The injection of vaporized hydrogen peroxide is followed by the injection of ozone, which reacts with residual hydrogen peroxide to form hydroxyl radicals. Sterilization efficacy was…

Read the full statement (638 words)

The STERIZONE® VP4 Sterilizer is intended for use in terminal sterilization of cleaned, rinsed, and dried metal and non-metal reusable medical devices in health care facilities.

The single pre-set cycle of the STERIZONE® VP4 Sterilizer uses hydrogen peroxide and ozone. The injection of vaporized hydrogen peroxide is followed by the injection of ozone, which reacts with residual hydrogen peroxide to form hydroxyl radicals.

Sterilization efficacy was demonstrated using a representative sample of one or more device types and packaging, in nine separate validation loads, as described in Table 1. The load to be processed should be maintained between 20°C to 26°C (68°F to 78°F). Total load weight shall not exceed 75 lbs, inclusive of the containers/packaging weight but excluding the 25 lbs loading rack.

Table 1. Description of the nine validation loads

Validation load #1 consisted of general medical instruments, representing the following geometries: Clamp, Serrated surface, Box-lock, Handle, Button, Pivot hinge, and Stopcock. Type of packaging used: wrapped plastic tray, including silicone mats and brackets, and Pouch. General medical instruments were spread out over three trays, six pouches and one wrapped instrument. Load weight: 11 lb.

Validation load #2 consisted of general medical instruments, representing the following geometries: Gliding mechanism, Hinges and screws, Serrated surface, Luer-lock, Spring, and Rigid non-lumen scopes. Type of packaging used: wrapped plastic and aluminum tray, including silicone mats and brackets, rigid aluminum container and Pouch. General medical instruments were spread out over one container, three trays, and six pouches. Load weight: 20 lb.

Validation load #3 consisted of three single channel flexible endoscopes (Ureteroscope) with inside diameter of 1.0 mm and length of 850 mm, packaged individually in wrapped trays or containers, including appropriate silicone brackets or mats. Eight general medical instruments, each packaged in a pouch, were added. Load weight: 23 lb.

Validation load #4 consisted of up to 15 rigid or semi-rigid channeled instruments in the presence of other packaged medical devices. Three double channel semi-rigid endoscopes (ureteroscope – 0.7 mm × 500 mm and 1.1 mm × 500 mm) were packaged individually in wrapped trays or containers including appropriate silicone brackets or mats. Additional rigid channeled instruments or stainless steel rigid lumens were added to each package. Two additional general medical instruments, each packaged in a pouch, were added. Load weight: 19 lb.

Validation load #5 consisted in two single channel flexible endoscopes; one Ureteroscope with inside diameter of 1.0 mm and length of 850 mm, and a Bronchoscope with inside diameter of 1.8 mm and length of 830 mm, and one double channel semi-rigid endoscope (ureteroscope – 0.7 mm × 500 mm and 1.1 mm × 500 mm), packaged individually in wrapped trays or containers including appropriate silicone brackets or mats. No additional item was added. Load weight: 21 lb.

Validation load #6 consisted of general medical instruments, representing the following geometries: Distal end (swivel parts), Hinge with screw, and Cannula. General medical instruments packaged in one aluminum sterilization container. Load weight: 9 lb.

Validation load #7 consisted of general medical instruments, representing the following geometries: Box-lock hinge, Pivot hinge, and Luer-lock. General medical instruments, spread out over three aluminum sterilization containers, each weighting 25 lb. Load weight: 75 lb.

Validation load #8 consisted of two double-channel flexible endoscopes (Ureteroscope) with inside diameter of 1 mm and lengths of 850 and 989 mm; and one single-channel flexible endoscopes (Ureteroscope) with inside diameter of 1 mm and length of 850 mm, packaged individually in wrapped plastic sterilization trays, including appropriate silicone brackets or mats. Load weight: 16 lb.

Validation load #9 consisted of one multi-channel flexible endoscope, with no more than 4 channels (Video Colonoscope), with inside diameters of 1.2 or more and lengths of 1955 mm or less, or 1.45 or more and lengths of 3500 mm or less; packaged in aluminium sterilization container. Load weight: 17 lb.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K153689: STERIZONE Sterilizer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K153689

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026