TSO3 Ozone Sterilizer, Model 125L

K020875510(k) TraditionalCleared Aug 26, 2003526-day reviewClass II21 CFR 880.6860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Technologies of Sterilization With Oxone, Tso3, Inc. · FLF Sterilizer, Ethylene-Oxide Gas

Cleared on Aug 26, 2003 after a 526-day review. The FDA summary names its predicate without a number. 24 later devices descend from it.

Decided
Aug 26, 2003
Review
526 days
Class
Class II
Product code
FLF
Recalls
None
Predicates
0

24 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2006: 1 descendant cleared2009: 1 descendant cleared2011: 3 descendants cleared2013: 1 descendant cleared2024: 1 descendant cleared2012: 1 descendant cleared2014: 2 descendants cleared2016: 3 descendants cleared2018: 4 descendants cleared2017: 1 descendant cleared2019: 4 descendants cleared2022: 2 descendants cleared200020052010201520202025
  1. This deviceK020875 TSO3 Ozone Sterilizer, Model 125LTechnologies of Sterilization With Oxone, Tso3, Inc. · 2003
  2. Descendant · cites it directly · 23 of its ownK051595 TSO3 Ozone Sterilizer, Model 125LTso3, Inc. · 2006
  3. Descendant · cites it directly · 22 of its ownK090636 TSO3 Ozone Sterilizer, Model 125LTso3, Inc. · 2009
  4. Descendant · 2 generations on · 21 of its ownK102330 Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation · 2011
  5. Descendant · 3 generations on · 18 of its ownK112760 Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation · 2011
  6. Descendant · 3 generations on · 17 of its ownK120632 Amsco V-Pro 1 Low/Plus/Max Temperature Sterilization SystemSTERIS Corporation · 2012

Showing 5 of 24 descendants. See all descendants

Descendants cleared per year

2006: 12009: 12011: 32012: 12013: 12014: 22016: 32017: 12018: 42019: 42022: 22024: 1
2006high 4 (2018) · low 0 (2007)2026

Most influential descendants

Showing 5 of 24 · See all
  • K051595TSO3 Ozone Sterilizer, Model 125LTso3, Inc. · 2006 · cites it directly23descendants
  • K090636TSO3 Ozone Sterilizer, Model 125LTso3, Inc. · 2009 · cites it directly22descendants
  • K102330Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation · 2011 · 2 generations on21descendants
  • K112760Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation · 2011 · 3 generations on18descendants
  • K120632Amsco V-Pro 1 Low/Plus/Max Temperature Sterilization SystemSTERIS Corporation · 2012 · 3 generations on17descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K020875TSO3 Ozone Sterilizer, Model 125LTechnologies of Sterilization With Oxone, Tso3, Inc.2003—
+1K051595TSO3 Ozone Sterilizer, Model 125LTso3, Inc.2006—
+1K090636TSO3 Ozone Sterilizer, Model 125LTso3, Inc.2009—
+2K102330Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation2011—
+3K112760Amsco V-Pro Max Low Temperature Sterilization SystemSTERIS Corporation2011—
+3K120632Amsco V-Pro 1 Low/Plus/Max Temperature Sterilization SystemSTERIS Corporation2012—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200610
200910
201130
201210
201310
201420
201630
201710
201840
201940
202220
202410
FIG. 1 — Lineage of K020875, 2003–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FLF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FLF device

  1. #1 K192978 EOGas 4 Ethylene Oxide Gas Sterilizerscore 0.6 · 2 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—STERRAD 100S Sterilization System
Named without a submission number
—

What descends from it? (24)

See all 24

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K051595TSO3 Ozone Sterilizer, Model 125LTso3, Inc.200623
K090636TSO3 Ozone Sterilizer, Model 125LTso3, Inc.200922

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K051595 (Tso3, Inc., 2006) has gone furthest, with 23 descendants of its own.

How does its category compare?

All FLF devices

FLF Sterilizer, Ethylene-Oxide Gas: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FLF

1in 2020

2009: 12015: 22017: 12020: 1
2007high 2 (2015) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FLF

Too few FLF 510(k)s in any year since 2007 to give a median.

Recalls per year · FLF

2in 2014

2009: 12012: 12013: 22014: 2
2007high 2 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FLF

4in 2021

2007: 22008: 12009: 22010: 32011: 42012: 52013: 32014: 62015: 32016: 32017: 32019: 22021: 4
2007high 6 (2014) · low 0 (2018)2025

MAUDE reports naming product code FLF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—02
20080—01
20091—12
20100—03
20110—04
20120—15
20130—23
20140—26
20152—03
20160—03
20171—03
20180—00
20190—02
20201—00
20210—04
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The TSO3-Model 125L is an Ozone Sterilizer intended for use in the sterilization processing of reusable medical devices in Health Care Facilities. The TSO3 Model 125L Ozone Sterilizer is designed for sterilization of both metal and non-metal medical devices at low temperatures. The sterilization cycle operates at very low pressure and low temperatures, consequently it is suitable for processing medical devices sensitive to heat and moisture. The…

Read the full statement (195 words)

The TSO3-Model 125L is an Ozone Sterilizer intended for use in the sterilization processing of reusable medical devices in Health Care Facilities. The TSO3 Model 125L Ozone Sterilizer is designed for sterilization of both metal and non-metal medical devices at low temperatures. The sterilization cycle operates at very low pressure and low temperatures, consequently it is suitable for processing medical devices sensitive to heat and moisture.

The TS03-125L Ozone Sterilizer is designed to sterilize instruments and devices with diffusion-restricted spaces, such as the hinged portion of forceps and scissors.

The TS03-125L Ozone Sterilizer is also designed to process medical devices having a single stainless steel lumen with:

- an inside diameter of 2 mm or larger and a length of 250 mm or shorter,

- an inside diameter of 3 mm or larger and a length of 470 mm or shorter;

- an inside diameter of 4 mm or larger and a length of 600 mm or shorter.

Note: Testing conducted employing half cycle with a SAL of 10⁻⁶ with no survivors.

The packaging compatible with the TSO3-Model 125L Ozone Sterilizer are TSO3 sterilization pouch and rigid anodized aluminum containers using disposable cellulose filter paper.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K020875: TSO3 Ozone Sterilizer, Model 125L.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K020875

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026