510(k) Report

510(k) · Cleared

Recalled · Class II · 2019

RT Elements, Cranial SRS, Spine SRS, Multiple Brain Mets SRS, RT QA, Adaptive Hybrid Surgery Analysis, Dose Review

K170750510(k) TraditionalCleared Aug 24, 2017164-day reviewClass II21 CFR 892.5050Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Brainlab AG · MUJ System, Planning, Radiation Therapy Treatment

Cleared on Aug 24, 2017 as substantially equivalent to K170355 (RaySearch Laboratories AB (PUBL), 2017) after a 164-day review. Its family tree reaches back 12 generations to 2001. It has been recalled once.

Decided
Aug 24, 2017
Review
164 days
Class
Class II
Product code
MUJ
Recalls
1
Predicates
1

Its longest line of descent runs back 12 generations to K010975 (2001). 67 ancestors in all, the oldest K802809 (1981). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2013: 1 other ancestor2012: 1 other ancestor2009: 2 other ancestors2002: 3 other ancestors2000: 5 other ancestors2011: 1 other ancestor2010: 1 other ancestor2008: 3 other ancestors2007: 1 other ancestor2003: 2 other ancestors2001: 5 other ancestors1999: 4 other ancestors1997: 2 other ancestors1996: 5 other ancestors2006: 2 other ancestors2005: 1 other ancestor2004: 2 other ancestors1992: 4 other ancestors1991: 1 other ancestor1994: 2 other ancestors1990: 2 other ancestors1989: 2 other ancestors1987: 1 other ancestor1986: 1 other ancestor1981: 1 other ancestorReference device: K142108 · RT Elements, Dose Review, Brain Metastases, Adaptive Hybrid Surgery Analysis · Brainlab AG · 2014 · recalledReference device: K103246 · Iplan RT · Brainlab AG · 2011 · recalledK010975 · Eclipse 6.5 · Varian Medical Systems, Inc. · 2001 · recalledK030981 · Eclipse · Varian Medical Systems, Inc. · 2003K041403 · Eclipse with Aaa · Varian Medical Systems · 2004K050296 · Eclipse Treatment Planning System · Varian Medical Systems · 2005×2: 2 generations cleared close together, K071873 (2007), K073020 (2007) K091492 · Modification to Eclipse Treatment Planning System · Varian Medical Systems, Inc. · 2009 · recalledK102216 · Xio RTP System · Computerized Medical Systems, Inc. · 2010 · recalledK140187 · Ray Station · Raysearch Laboratories AB · 2014 · recalledK141860 · Raystation · Raysearch Laboratories AB · 2014 · recalledK160093 · RayStation · RaySearch Laboratories AB (PUBL) · 2016 · recalledK170355 · RayStation 6 · RaySearch Laboratories AB (PUBL) · 2017 · recalled1980199020002010
  1. Root · 12 generations backK010975 Eclipse 6.5Varian Medical Systems, Inc. · 2001 · Recalled
  2. 8 generations between
  3. 3 generations backK141860 RaystationRaysearch Laboratories AB · 2014 · Recalled
  4. 2 generations backK160093 RayStationRaySearch Laboratories AB (PUBL) · 2016 · Recalled
  5. 1 generation backK170355 RayStation 6RaySearch Laboratories AB (PUBL) · 2017 · Recalled
  6. This deviceK170750 RT Elements, Cranial SRS, Spine SRS, Multiple Brain Mets SRS, RT QA…Brainlab AG · 2017
Show all 12 generations
  1. Root · 12 generations backK010975 Eclipse 6.5Varian Medical Systems, Inc. · 2001 · Recalled
  2. 11 generations backK030981 EclipseVarian Medical Systems, Inc. · 2003
  3. 10 generations backK041403 Eclipse with AaaVarian Medical Systems · 2004
  4. 9 generations backK050296 Eclipse Treatment Planning SystemVarian Medical Systems · 2005
  5. 8 generations backK071873 Modification to Eclipse Treatment Planning SystemVarian Medical Systems, Inc. · 2007 · Recalled
  6. 7 generations backK073020 Eclipse Treatment Planning SystemVarian Medical Systems, Inc. · 2007 · Recalled
  7. 6 generations backK091492 Modification to Eclipse Treatment Planning SystemVarian Medical Systems, Inc. · 2009 · Recalled
  8. 5 generations backK102216 Xio RTP SystemComputerized Medical Systems, Inc. · 2010 · Recalled
  9. 4 generations backK140187 Ray StationRaysearch Laboratories AB · 2014 · Recalled
  10. 3 generations backK141860 RaystationRaysearch Laboratories AB · 2014 · Recalled
  11. 2 generations backK160093 RayStationRaySearch Laboratories AB (PUBL) · 2016 · Recalled
  12. 1 generation backK170355 RayStation 6RaySearch Laboratories AB (PUBL) · 2017 · Recalled
  13. This deviceK170750 RT Elements, Cranial SRS, Spine SRS, Multiple Brain Mets SRS, RT QA…Brainlab AG · 2017
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−12K010975Eclipse 6.5Varian Medical Systems, Inc.20013
−11K030981EclipseVarian Medical Systems, Inc.2003—
−10K041403Eclipse with AaaVarian Medical Systems2004—
−9K050296Eclipse Treatment Planning SystemVarian Medical Systems2005—
−8K071873Modification to Eclipse Treatment Planning SystemVarian Medical Systems, Inc.20075
−7K073020Eclipse Treatment Planning SystemVarian Medical Systems, Inc.20076
−6K091492Modification to Eclipse Treatment Planning SystemVarian Medical Systems, Inc.20092
−5K102216Xio RTP SystemComputerized Medical Systems, Inc.20107
−4K140187Ray StationRaysearch Laboratories AB20141
−3K141860RaystationRaysearch Laboratories AB20145
−2K160093RayStationRaySearch Laboratories AB (PUBL)20167
−1K170355RayStation 6RaySearch Laboratories AB (PUBL)20171
0 (this device)K170750RT Elements, Cranial SRS, Spine SRS, Multiple Brain Mets SRS, RT QA, Adaptive…Brainlab AG2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198110
198610
198710
198920
199020
199110
199240
199420
199650
199720
199940
200050
200150
200230
200320
200420
200510
200620
200710
200830
200920
201010
201110
201210
201310
FIG. 1 — Lineage of K170750, 2001–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MUJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MUJ device

  1. #1 K232799 syngo.via RT Image Suitescore 18.6 · 19 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K170355RayStation 6
Summary page 4
…ets SRS, Cranial SRS, Spine SRS, RT QA Common/Classific System, Planning, Radiation Therapy Treatment ation Name: Primary K170355 Raystation 6 predicate Device: Reference K142108 RT Elements Devices: K103246 iPlan RT Device class…
RaySearch Laboratories AB (PUBL)20171
†K142108RT Elements, Dose Review, Brain Metastases, Adaptive Hybrid Surgery AnalysisBrainlab AG20143
†K103246Iplan RTBrainlab AG20112

Also cleared against K170355: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 11, 2019Class IIZ-1205-2019Device DesignThere is a potential for an incorrect dose distribution calculation by Brainlab RT Elements software (for affected versions) under specific circumstances when using the Pencil Beam algorithm on the GPU (graphics card), as is the default…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 6 companies; a new generation was cleared every 1.3 years on median.
  • 22 of the 67 ancestors have a recall of any class.
  • 1 other device also cites its predicate K170355.

How does its category compare?

All MUJ devices

MUJ System, Planning, Radiation Therapy Treatment: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · MUJ

10in 2025

2007: 42008: 92009: 162010: 112011: 92012: 82013: 52014: 92015: 132016: 52017: 72018: 72019: 92020: 92021: 112022: 82023: 102024: 92025: 102026 (partial year): 9
2007high 16 (2009) · low 4 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MUJ

186in 2025

2007: 67 days median2008: 63 days median2009: 84 days median2010: 56 days median2011: 103 days median2012: 59 days median2013: 64 days median2014: 108 days median2015: 78 days median2016: 80 days median2017: 30 days median2018: 53 days median2019: 56 days median2020: 104 days median2021: 87 days median2022: 168 days median2023: 140 days median2024: 122 days median2025: 186 days median2026 (partial year): 233 days median
2007high 233 (2026) · low 30 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MUJ

2in 2023

2007: 42008: 102009: 112010: 232011: 172012: 42013: 62014: 22015: 72016: 132017: 42018: 32019: 42020: 22021: 42022: 32023: 22026 (partial year): 2
2007high 23 (2010) · low 0 (2024)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MUJ

21in 2025

2007: 242008: 512009: 242010: 782011: 732012: 392013: 332014: 352015: 302016: 272017: 162018: 252019: 252020: 262021: 152022: 222023: 762024: 92025: 21
2007high 78 (2010) · low 9 (2024)2025

MAUDE reports naming product code MUJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007467424
20089631051
200916841124
201011562378
201191031773
2012859439
2013564633
20149108235
20151378730
20165801327
2017730416
2018753325
2019956425
20209104226
20211187415
20228168322
202310140276
2024912209
202510186021
202692332—

What is it indicated for?

The RT Elements are applications for radiation treatment planning for use in stereotactic, conformal, computer planned, Linac based radiation treatment of cranial, head and neck, and extracranial lesions. The "Dose Review" application as one RT Element contains features for review of isodose lines, review of DVHs, dose comparison and dose summation. The "Multiple Brain Mets SRS" application as one RT Element provides optimized planning and display for…

Read the full statement (180 words)

The RT Elements are applications for radiation treatment planning for use in stereotactic, conformal, computer planned, Linac based radiation treatment of cranial, head and neck, and extracranial lesions.

The "Dose Review" application as one RT Element contains features for review of isodose lines, review of DVHs, dose comparison and dose summation.

The "Multiple Brain Mets SRS" application as one RT Element provides optimized planning and display for cranial multi-metastases radiation treatment planning.

The "Adaptive Hybrid Surgery Analysis" application as one RT Element simulates an automated template-based radiation treatment plan. The simulated plan is intended for treatment evaluation for example in tumor board meetings or operating rooms.

The "Cranial SRS" application as one RT Element provides optimized planning and display for cranial radiation treatment planning.

The “Spine SRS” application as one RT Element provides optimized planning and display for single spine metastases.

"RT QA" is an accessory to the RT Elements and contains features for patient specific quality assurance.

Use "RT QA" to recalculate patient treatment plans on a phantom to verify that the patient treatment plan fulfills the planning requirements.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K170750: RT Elements, Cranial SRS, Spine SRS, Multiple Brain Mets SRS, RT QA, Adaptive Hybrid Surgery Analysis, Dose Review.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K170750

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026