510(k) · Cleared
ClearedBeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19, BeneVision N22, BeneVision N1
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms)
Cleared on Jan 7, 2021 as substantially equivalent to K192972 (Shenzhen Mindray Bio-Medical Electronics Co., Ltd., 2020) after a 139-day review. Its family tree reaches back 2 generations to 2018. 4 later devices descend from it.
- Decided
- Jan 7, 2021
- Review
- 139 days
- Class
- Class II
- Product code
- MHX
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K182075 (2018). 4 later devices descend from it, 2 citing it directly.
- Root · 2 generations backK182075 BeneVision N Series Patient Monitors (Including BeneVision N12…Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2018
- 1 generation backK192972 Patient MonitorShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2020
- This deviceK202405 BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19…Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2021
- Descendant · cites it directly · 2 of its ownK213799 N Series Patient MonitorsShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2022 · Recalled
- Descendant · cites it directly · 1 of its ownK220107 Mindray SV600 Ventilator, Mindray SV800 VentilatorShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2023
- Descendant · 2 generations on · 0 of its ownK250854 Multi-parameter Patient Monitor (N10); Multi-parameter Patient…Shenzhen Comen Medical Instruments Co.,Ltd · 2025
- Descendant · 2 generations on · 0 of its ownK243767 SV600, SV800 VentilatorShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2025
Most influential descendants
Showing 4 of 4 · See all- K213799N Series Patient MonitorsShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2022 · cites it directly2descendants
- K220107Mindray SV600 Ventilator, Mindray SV800 VentilatorShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2023 · cites it directly1descendant
- K250854Multi-parameter Patient Monitor (N10); Multi-parameter Patient Monitor (N12)…Shenzhen Comen Medical Instruments Co.,Ltd · 2025 · 2 generations on0descendants
- K243767SV600, SV800 VentilatorShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2025 · 2 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K182075 | BeneVision N Series Patient Monitors (Including BeneVision N12, BeneVision… | Shenzhen Mindray Bio-Medical Electronics Co., Ltd. | 2018 | — |
| −1 | K192972 | Patient Monitor | Shenzhen Mindray Bio-Medical Electronics Co., Ltd. | 2020 | — |
| 0 (this device) | K202405 | BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19, BeneVision… | Shenzhen Mindray Bio-Medical Electronics Co., Ltd. | 2021 | — |
| +1 | K213799 | N Series Patient Monitors | Shenzhen Mindray Bio-Medical Electronics Co., Ltd. | 2022 | 2 |
| +1 | K220107 | Mindray SV600 Ventilator, Mindray SV800 Ventilator | Shenzhen Mindray Bio-Medical Electronics Co., Ltd. | 2023 | — |
| +2 | K250854 | Multi-parameter Patient Monitor (N10); Multi-parameter Patient Monitor (N12)… | Shenzhen Comen Medical Instruments Co.,Ltd | 2025 | — |
| +2 | K243767 | SV600, SV800 Ventilator | Shenzhen Mindray Bio-Medical Electronics Co., Ltd. | 2025 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2022 | 1 | 0 |
| 2023 | 1 | 0 |
| 2025 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MHX device
- #1 K251702 IntelliVue Patient Monitor MX750; IntelliVue…score 23.0 · 40 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K192972 | Patient MonitorSummary page 7…r electroencephalograph 882.1320, II GXY Cutaneous electrode. Electrode, cutaneous 3. PREDICATE DEVICES • Predicate: K192972 – BeneVision N Series Patient Monitors (Including BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19, BeneVi… | 2020 |
| † | K200015 | ePM Series Patient monitors | 2020 |
What descends from it? (4)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 3 years and passes through 1 company; a new generation was cleared every 1.4 years on median.
- None of the 2 ancestors has a recall.
- Of its descendants, K213799 (Shenzhen Mindray Bio-Medical Electronics Co., Ltd., 2022) has gone furthest, with 2 descendants of its own.
- 1 other device also cites its predicate K192972.
How does its category compare?
All MHX devicesMHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.
FDA decisions per year · MHX
8in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MHX
192in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MHX
21so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MHX
3,761in 2025
MAUDE reports naming product code MHX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 15 | 96 | 3 | 131 |
| 2008 | 16 | 58 | 2 | 232 |
| 2009 | 13 | 57 | 7 | 382 |
| 2010 | 20 | 90 | 13 | 955 |
| 2011 | 12 | 81 | 16 | 949 |
| 2012 | 16 | 88 | 11 | 676 |
| 2013 | 21 | 120 | 14 | 1,997 |
| 2014 | 13 | 248 | 6 | 1,609 |
| 2015 | 14 | 203 | 5 | 1,284 |
| 2016 | 13 | 149 | 7 | 1,105 |
| 2017 | 14 | 134 | 6 | 1,115 |
| 2018 | 11 | 203 | 12 | 2,157 |
| 2019 | 7 | 243 | 6 | 1,462 |
| 2020 | 11 | 196 | 0 | 1,714 |
| 2021 | 5 | 195 | 0 | 2,423 |
| 2022 | 15 | 189 | 6 | 1,470 |
| 2023 | 8 | 229 | 3 | 2,254 |
| 2024 | 5 | 181 | 3 | 2,814 |
| 2025 | 8 | 192 | 15 | 3,761 |
| 2026 | 14 | 205 | 21 | — |
What is it indicated for?
BeneVision N12/N15/N17/N19/N22 The BeneVision N12/N15/N17/N19/N22 patient monitors are intended for monitoring, displaying, reviewing, storing, alarming, and transferring of multiple physiological parameters including ECG (3-lead, 5-lead, 6-lead or 12-lead selectable, Arrhythmia Detection, ST Segment Analysis, QT Analysis, and Heart Rate (HR)), Respiration Rate (Resp), Temperature (Temp), Pulse Oxygen Saturation (SpO2), Pulse Rate (PR), Non-invasive…
Read the full statement (422 words)
BeneVision N12/N15/N17/N19/N22
The BeneVision N12/N15/N17/N19/N22 patient monitors are intended for monitoring, displaying, reviewing, storing, alarming, and transferring of multiple physiological parameters including ECG (3-lead, 5-lead, 6-lead or 12-lead selectable, Arrhythmia Detection, ST Segment Analysis, QT Analysis, and Heart Rate (HR)), Respiration Rate (Resp), Temperature (Temp), Pulse Oxygen Saturation (SpO2), Pulse Rate (PR), Non-invasive Blood Pressure (NIBP), Invasive Blood Pressure(IBP), Pulmonary Artery Wedge Pressure (PAWP), Cardiac Output (C.O.), Continuous Cardiac Output (CCO), Mixed/Central Venous Oxygen Saturation (SvO2/ScvO2), Carbon Dioxide (CO2), Oxygen (O2), Anesthetic Gas (AG), Impedance Cardiograph (ICG), Bispectral Index (BIS), Respiration Mechanics (RM), Neuromuscular Transmission Monitoring (NMT), Electroencephalograph (EEG), and Regional Oxygen Saturation (rSO2). The system also provides an interpretation of resting 12-lead ECG.
All the parameters can be monitored on single adult, pediatric, and neonatal patients except for the following:
* BIS, RM, CCO, SvO2/ScvO2, PAWP, and NMT monitoring, PNP, and PNC are intended for adult and pediatric patients only;
* C.O. monitoring and A-Fib are intended for adult patients only;
* ICG monitoring is intended for only adult patients who meet the following requirements: height: 122 to 229cm, weight: 30 to 155kg.
* rSO2 monitoring is intended for use in individuals greater than 2.5kg.
The monitors are to be used in healthcare facilities by clinical professionals or under their guidance. They should only be used by persons who have received adequate training in their use. The BeneVision N12/N15/N17/N19/N22 monitors are not intended for helicopter transport, hospital ambulance, or home use.
BeneVision N1 Patient Monitor:
The BeneVision N1 Patient Monitor is intended for monitoring, displaying, reviewing, storing, alarming, and transferring of multiple physiological parameters including ECG (3-lead, 5-lead, 6-lead or 12-lead selectable, Arrhythmia Detection, ST Segment Analysis, QT Analysis, and Heart Rate (HR)), Respiration (Resp), Temperature (Temp), Pulse Oxygen Saturation (SpO2), Pulse Rate (PR), Non-invasive Blood Pressure (NIBP), Invasive Blood Pressure (IBP) , Pulmonary Artery Wedge Pressure (PAWP), Carbon Dioxide (CO2) and Oxygen (O2). The system also provides an interpretation of resting 12-lead ECG.
All the parameters can be monitored on single adult, pediatric, and neonatal patients except for the following:
• PAWP, PNP, and PNC are intended for adult and pediatric patients only;
• A-Fib is intended for adult patients only;
The BeneVision N1 monitor is to be used in healthcare facilities. It can also be used during patient transport inside and outside of the hospital environment. It should be used by clinical professionals or under their guidance. It should only be used by persons who have received adequate training in its use. It is not intended for home use.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K202405 · printed Nov 6, 2026
Cite this page
510(k) Report. “K202405: BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19, BeneVision N22, BeneVision N1.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K202405
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026