510(k) Report

510(k) · Cleared

Cleared

Multi-parameter Patient Monitor (N10); Multi-parameter Patient Monitor (N12); Multi-parameter Patient Monitor (N15); Multi-parameter Patient Monitor (N10MPro); Multi-parameter Patient Monitor (N12MPro); Multi-parameter Patient Monitor (N15MPro)

K250854510(k) TraditionalCleared Dec 17, 2025271-day reviewClass II21 CFR 870.1025

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Shenzhen Comen Medical Instruments Co.,Ltd · MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms)

Cleared on Dec 17, 2025 as substantially equivalent to K213799 (Shenzhen Mindray Bio-Medical Electronics Co., Ltd., 2022) after a 271-day review. Its family tree reaches back 4 generations to 2018.

Decided
Dec 17, 2025
Review
271 days
Class
Class II
Product code
MHX
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K182075 (2018). No later device cites it as a predicate yet.

Reference device: K211619 · Multi-Parameter Patient Monitor · Shenzhen Comen Medical Instruments Co.,Ltd · 2022Reference device: K193242 · Masimo Rad-97 Pulse CO-Oximeter and Accessories, Masimo Radical-7 Pulse CO-Oximeter and Accessories, Masimo Radius-7 Pulse CO-Oximeter and Accessories · Masimo Corporation · 2020Reference device: K123043 · Irma C02 Model 200101; Irma AX 200601 · Phasein AB · 2012Reference device: K171121 · Masimo Root Monitoring System and Accessories · Masimo Corporation · 2017Reference device: K042601 · Capnostat 5 · Respironics Novametrix, Inc. · 2004 · recalledReference device: K103604 · Isa CO2, Isa AX+, Isa or+ · Phasein AB · 2011Reference device: K040183 · BISX · Aspect Medical Systems, Inc. · 2004Reference device: K102084 · Stimpod NMS450 Nerve Stimulator · Xavant Technology (Pty), Ltd. · 2010Reference device: K231160 · Cardio Q50, Cardio Q70 · Bionet Co., Ltd. · 2023K182075 · BeneVision N Series Patient Monitors (Including BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19. BeneVision N22, BeneVision N1) · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2018K192972 · Patient Monitor · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2020K202405 · BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19, BeneVision N22, BeneVision N1 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2021K213799 · N Series Patient Monitors · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2022 · recalled201620182020202220242026
  1. Root · 4 generations backK182075 BeneVision N Series Patient Monitors (Including BeneVision N12…Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2018
  2. 3 generations backK192972 Patient MonitorShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2020
  3. 2 generations backK202405 BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19…Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2021
  4. 1 generation backK213799 N Series Patient MonitorsShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2022 · Recalled
  5. This deviceK250854 Multi-parameter Patient Monitor (N10); Multi-parameter Patient…Shenzhen Comen Medical Instruments Co.,Ltd · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K182075BeneVision N Series Patient Monitors (Including BeneVision N12, BeneVision…Shenzhen Mindray Bio-Medical Electronics Co., Ltd.2018—
−3K192972Patient MonitorShenzhen Mindray Bio-Medical Electronics Co., Ltd.2020—
−2K202405BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19, BeneVision…Shenzhen Mindray Bio-Medical Electronics Co., Ltd.2021—
−1K213799N Series Patient MonitorsShenzhen Mindray Bio-Medical Electronics Co., Ltd.20222
0 (this device)K250854Multi-parameter Patient Monitor (N10); Multi-parameter Patient Monitor (N12)…Shenzhen Comen Medical Instruments Co.,Ltd2025—
FIG. 1 — Lineage of K250854, 2018–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MHX device

  1. #1 K251702 IntelliVue Patient Monitor MX750; IntelliVue…score 23.0 · 40 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K213799N Series Patient Monitors
Summary page 7
…Page 2 of 22 510(k) Premarket Notification 510(k) Summary K250854 3. Predicate device K213799 - BeneVision N series Patient Monitors (including BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19, BeneVision N22)…
Shenzhen Mindray Bio-Medical Electronics Co., Ltd.20222
†K211619Multi-Parameter Patient MonitorShenzhen Comen Medical Instruments Co.,Ltd2022—
†K193242Masimo Rad-97 Pulse CO-Oximeter and Accessories, Masimo Radical-7 Pulse CO-Oximeter and…Masimo Corporation2020—
†K123043Irma C02 Model 200101; Irma AX 200601Phasein AB2012—
†K171121Masimo Root Monitoring System and AccessoriesMasimo Corporation2017—
†K042601Capnostat 5Respironics Novametrix, Inc.20041
†K103604Isa CO2, Isa AX+, Isa or+Phasein AB2011—
†K040183BISXAspect Medical Systems, Inc.2004—
†K102084Stimpod NMS450 Nerve StimulatorXavant Technology (Pty), Ltd.2010—
†K231160Cardio Q50, Cardio Q70Bionet Co., Ltd.2023—

Also cleared against K213799: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 2 companies; a new generation was cleared every 1.5 years on median.
  • 1 of the 4 ancestors has a recall of any class.
  • 1 other device also cites its predicate K213799.

How does its category compare?

All MHX devices

MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · MHX

8in 2025

2007: 152008: 162009: 132010: 202011: 122012: 162013: 212014: 132015: 142016: 132017: 142018: 112019: 72020: 112021: 52022: 152023: 82024: 52025: 82026 (partial year): 14
2007high 21 (2013) · low 5 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MHX

192in 2025

2007: 96 days median2008: 58 days median2009: 57 days median2010: 90 days median2011: 81 days median2012: 88 days median2013: 120 days median2014: 248 days median2015: 203 days median2016: 149 days median2017: 134 days median2018: 203 days median2019: 243 days median2020: 196 days median2021: 195 days median2022: 189 days median2023: 229 days median2024: 181 days median2025: 192 days median2026 (partial year): 205 days median
2007high 248 (2014) · low 57 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MHX

21so far in 2026, the most since 2007

2007: 32008: 22009: 72010: 132011: 162012: 112013: 142014: 62015: 52016: 72017: 62018: 122019: 62022: 62023: 32024: 32025: 152026 (partial year): 21
2007high 21 (2026) · low 0 (2020)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MHX

3,761in 2025

2007: 1312008: 2322009: 3822010: 9552011: 9492012: 6762013: 1,9972014: 1,6092015: 1,2842016: 1,1052017: 1,1152018: 2,1572019: 1,4622020: 1,7142021: 2,4232022: 1,4702023: 2,2542024: 2,8142025: 3,761
2007high 3,761 (2025) · low 131 (2007)2025

MAUDE reports naming product code MHX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200715963131
200816582232
200913577382
2010209013955
2011128116949
2012168811676
201321120141,997
20141324861,609
20151420351,284
20161314971,105
20171413461,115
201811203122,157
2019724361,462
20201119601,714
2021519502,423
20221518961,470
2023822932,254
2024518132,814
20258192153,761
20261420521—

What is it indicated for?

The N10, N12, N15, N1OMPro, N12MPro, NM15Pro Multi-parameter Patient Monitors are intended for monitoring, displaying, reviewing, storing, alarming and transferring of multiple physiological parameters including ECG (3-lead, 5-lead, 12-lead selectable), Arrhythmia Analysis, ST Segment Analysis, QT Analysis, Heart Rate (HR) and Heart-Rate-Variability(HRV)), interpretations of resting 12-lead ECG, Respiration rate(Resp), Temperature(Temp), Pulse Oxygen…

Read the full statement (317 words)

The N10, N12, N15, N1OMPro, N12MPro, NM15Pro Multi-parameter Patient Monitors are intended for monitoring, displaying, reviewing, storing, alarming and transferring of multiple physiological parameters including ECG (3-lead, 5-lead, 12-lead selectable), Arrhythmia Analysis, ST Segment Analysis, QT Analysis, Heart Rate (HR) and Heart-Rate-Variability(HRV)), interpretations of resting 12-lead ECG, Respiration rate(Resp), Temperature(Temp), Pulse Oxygen Saturation (SpO2), Pulse Rate (PR), Non-invasive Blood Pressure (NIBP), Invasive Blood Pressure (IBP), Pulmonary Artery Wedge Pressure (PAWP), Cardiac Output (C.O.), Carbon Dioxide (C02). The N10MPro, N12MPro, NM15Pro Multi-parameter Patient Monitors are also intended for monitoring, displaying, reviewing, storing, alarming and transferring of physiological parameters including Masimo Rainbow SpO2, Anesthesia gas (AG), oxygen (02) respiratory gas monitoring, Bispectral Index (BIS), Respiration Mechanics (RM) and Neuromuscular Transmission Monitoring (NMT). All the parameters can be monitored on single adult, pediatric, and neonatal patient except for the following:

- Arrhythmia analysis is intended to use on adult patients only and is not intended and shall not be used on pediatric and neonatal population.

-NIBP measurement continual mode is not applicable to neonates.

- When using COMEN SpO2, the monitor is intended to be used on adult patient only.

- PAWP is intended for adult and pediatric patients only.

- C.O. measurement is intended for adult patients only.

- BIS monitoring is intended for adult patients only.

- RM is intended for adult and pediatric patients only.

- NMT monitoring is intended for adult and pediatric patients only.

The monitors are to be used in healthcare facilities by healthcare professionals or under their guidance.

The Multi-parameter Patient monitors are not intended for emergency and transport use, aircraft environment or home use.

The monitors are not intend for use as apnea monitors.

The monitors are not intended for use in MRI or CT environments.

The monitors are not used on patients who have a demonstrated need for cardiac monitoring known arrhythmias of VT, Accelerated Idioventricular rhythm and Torsades de Pointes.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K250854: Multi-parameter Patient Monitor (N10); Multi-parameter Patient Monitor (N12); Multi-parameter Patient Monitor (N15); Multi-parameter Patient Monitor (N10MPro); Multi-parameter Patient Monitor (N12MPro); Multi-parameter Patient Monitor (N15MPro).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K250854

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026