ArtFx Corpectomy Cages (Espinax and Distractania Corpectomy Cages)

K211892510(k) TraditionalCleared Oct 6, 2022472-day reviewClass II21 CFR 888.3060

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Arftx Medical, LLC · MQP Spinal Vertebral Body Replacement Device

Cleared on Oct 6, 2022 as substantially equivalent to K192117 (Ulrich GmbH & Co. KG, 2019) after a 472-day review. Its family tree reaches back 16 generations to 1984. 2 later devices descend from it.

Decided
Oct 6, 2022
Review
472 days
Class
Class II
Product code
MQP
Recalls
None
Predicates
1

Its longest line of descent runs back 16 generations to K841189 (1984). 64 ancestors in all. 2 later devices descend from it, 1 citing it directly.

  1. Root · 16 generations backK841189 Oec/Rezaian Spinal FixatorOrthopedic Equipment Co., Inc. · 1984
  2. 12 generations between
  3. 3 generations backK162315 FORTIFY Corpectomy SpacersGlobus Medical, Inc. · 2017
  4. 2 generations backK173982 FORTIFY Corpectomy SpacersGlobus Medical, Inc. · 2018
  5. 1 generation backK192117 Small VBR™Ulrich GmbH & Co. KG · 2019
  6. This deviceK211892 ArtFx Corpectomy Cages (Espinax and Distractania Corpectomy Cages)Arftx Medical, LLC · 2022
  7. Descendant · cites it directly · 1 of its ownK252686 EffortMed PEEK Cages & Corpectomy CagesEffortmed, LLC · 2025
  8. Descendant · 2 generations on · 0 of its ownK260850 Osteomni Spinal Cages SystemOsteomni, Inc. · 2026
Show all 16 generations
  1. Root · 16 generations backK841189 Oec/Rezaian Spinal FixatorOrthopedic Equipment Co., Inc. · 1984
  2. 15 generations backK990148 Stackable Cage SystemDepuy Motech Acromed · 1999
  3. 14 generations backK003043 Surgical Titanium Mesh SystemDepuyacromed · 2001
  4. 13 generations backK022793 Tetris Spinal ImplantSignus Medical, LLC · 2003
  5. 12 generations backK031757 Peek Tetris Spinal ImplantSignus Medical, LLC · 2003
  6. 11 generations backK033109 Ellys and Aurys Vertebral Body ReplacementsScient'X · 2004
  7. 10 generations backK043479 MC+ Partial VBRLdr Spine USA · 2005
  8. 9 generations backK080728 LDR Spine Roi-C ImplantLdr Spine USA · 2008
  9. 8 generations backK083857 LDR Spine Roi-C ImplantLdr Spine USA · 2009
  10. 7 generations backK091088 LDR Spine Cervical Interbody Fusion SystemLdr Spine USA · 2009
  11. 6 generations backK121176 STGCCardinal Spine, LLC · 2012
  12. 5 generations backK142030 STGC-LordoticCardinal Spine, LLC · 2015
  13. 4 generations backK152568 C-VBRCardinal Spine, LLC · 2016
  14. 3 generations backK162315 FORTIFY Corpectomy SpacersGlobus Medical, Inc. · 2017
  15. 2 generations backK173982 FORTIFY Corpectomy SpacersGlobus Medical, Inc. · 2018
  16. 1 generation backK192117 Small VBR™Ulrich GmbH & Co. KG · 2019
  17. This deviceK211892 ArtFx Corpectomy Cages (Espinax and Distractania Corpectomy Cages)Arftx Medical, LLC · 2022

Most influential descendants

Showing 2 of 2 · See all
  • K252686EffortMed PEEK Cages & Corpectomy CagesEffortmed, LLC · 2025 · cites it directly1descendant
  • K260850Osteomni Spinal Cages SystemOsteomni, Inc. · 2026 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−16K841189Oec/Rezaian Spinal FixatorOrthopedic Equipment Co., Inc.1984—
−15K990148Stackable Cage SystemDepuy Motech Acromed1999—
−14K003043Surgical Titanium Mesh SystemDepuyacromed2001—
−13K022793Tetris Spinal ImplantSignus Medical, LLC2003—
−12K031757Peek Tetris Spinal ImplantSignus Medical, LLC2003—
−11K033109Ellys and Aurys Vertebral Body ReplacementsScient'X2004—
−10K043479MC+ Partial VBRLdr Spine USA2005—
−9K080728LDR Spine Roi-C ImplantLdr Spine USA2008—
−8K083857LDR Spine Roi-C ImplantLdr Spine USA2009—
−7K091088LDR Spine Cervical Interbody Fusion SystemLdr Spine USA2009—
−6K121176STGCCardinal Spine, LLC2012—
−5K142030STGC-LordoticCardinal Spine, LLC2015—
−4K152568C-VBRCardinal Spine, LLC2016—
−3K162315FORTIFY Corpectomy SpacersGlobus Medical, Inc.2017—
−2K173982FORTIFY Corpectomy SpacersGlobus Medical, Inc.2018—
−1K192117Small VBR™Ulrich GmbH & Co. KG2019—
0 (this device)K211892ArtFx Corpectomy Cages (Espinax and Distractania Corpectomy Cages)Arftx Medical, LLC2022—
+1K252686EffortMed PEEK Cages & Corpectomy CagesEffortmed, LLC2025—
+2K260850Osteomni Spinal Cages SystemOsteomni, Inc.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010
200190
200270
200380
200480
200540
200640
200820
200910
201110
201310
201520

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
202610
FIG. 1 — Lineage of K211892, 1984–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQP device

  1. #1 K261810 Vertiwedge® Intraosseous Systemscore 18.1 · 22 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K192117Small VBR™
Summary page 6
…BR REGULATION NUMBER: 21 CFR 888.3060 REGULATION NAME: SPINAL INTERVERTEBRAL BODY FIXATION ORTHOSIS REGULATORY CLASS: Class II PRODUCT CODE: MQP, PLR 510(K) NUMBER: K192117 CONCLUSION: The ARTFX CORPECTOMY CAGE has the same intended use and technological characteristics as the predicate device. Ther…
Ulrich GmbH & Co. KG2019—

Also cleared against K192117: 2 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K252686EffortMed PEEK Cages & Corpectomy CagesEffortmed, LLC20251

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 38 years and passes through 10 companies; a new generation was cleared every 1.7 years on median.
  • 6 of the 64 ancestors have a recall of any class.
  • Of its descendants, K252686 (Effortmed, LLC, 2025) has gone furthest, with 1 descendant of its own.
  • 2 other devices also cite its predicate K192117.

How does its category compare?

All MQP devices

MQP Spinal Vertebral Body Replacement Device: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · MQP

4in 2024

2007: 302008: 172009: 112010: 62011: 82012: 72013: 32014: 52015: 82017: 92018: 62019: 82020: 32022: 12023: 12024: 42026 (partial year): 3
2007high 30 (2007) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQP

187in 2024

2007: 107 days median2008: 47 days median2009: 115 days median2010: 174 days median2011: 237 days median2012: 82 days median2013: 90 days median2014: 125 days median2015: 126 days median2017: 97 days median2018: 152 days median2019: 93 days median2020: 103 days median2024: 187 days median2026 (partial year): 102 days median
2007high 237 (2011) · low 47 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQP

1in 2022

2007: 22009: 142010: 22011: 12012: 22020: 152022: 1
2007high 15 (2020) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQP

168in 2025

2007: 612008: 762009: 1112010: 1662011: 1212012: 1412013: 2072014: 2162015: 2582016: 1292017: 1412018: 1302019: 1172020: 1572021: 2082022: 1372023: 712024: 982025: 168
2007high 258 (2015) · low 61 (2007)2025

MAUDE reports naming product code MQP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200730107261
20081747076
20091111514111
201061742166
201182371121
20127822141
20133900207
201451250216
201581260258
20160—0129
20179970141
201861520130
20198930117
2020310315157
20210—0208
20221—1137
20231—071
20244187098
20250—0168
202631020—

What is it indicated for?

The ESPINAX CORPECTOMY CAGE is intended for use in skeletally mature patients in the cervical spine (C2-T1) to replace a collapsed, damaged, or unstable vertebral body due to tumor, osteomyelitis, trauma (i.e. fracture), or for reconstruction following corpectomy performed to achieve decompression of the spinal cord and neural tissues in degenerative disorders. The DISTRACTANIA CORPECTOMY CAGE is intended for use in skeletally mature patients in the…

Read the full statement (200 words)

The ESPINAX CORPECTOMY CAGE is intended for use in skeletally mature patients in the cervical spine (C2-T1) to replace a collapsed, damaged, or unstable vertebral body due to tumor, osteomyelitis, trauma (i.e. fracture), or for reconstruction following corpectomy performed to achieve decompression of the spinal cord and neural tissues in degenerative disorders.

The DISTRACTANIA CORPECTOMY CAGE is intended for use in skeletally mature patients in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstable vertebral body due to tumor, osteomyelitis, trauma (i.e. fracture), or for reconstruction following corpectomy performed to achieve decompression of the spinal cord and neural tissues in degenerative disorders.

The ESPINAX and DISTRACTANIA CORPECTOMY CAGES are also intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical, thoracic, and lumbar spine in whom life expectancy is of insufficient duration to permit achievement of fusion, with bone graft used at the surgeon’s discretion.

The ESPINAX and DISTRACTANIA CORPECTOMY CAGES are intended to be used with supplemental spinal fixation systems cleared for use in the cervical, thoracic, and/or lumbar spine. The use of bone grafting material is optional.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K211892: ArtFx Corpectomy Cages (Espinax and Distractania Corpectomy Cages).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K211892

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026