510(k) · Cleared
Recalled · Class II · 2023ProxiDiagnost N90
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Philips Medical Systems Dmc GmbH · JAA System, X-Ray, Fluoroscopic, Image-Intensified
Cleared on Sep 21, 2021 as substantially equivalent to K173433 (Philips Medical Systems Dmc GmbH, 2018) after a 14-day review. Its family tree reaches back 4 generations to 1992. 1 later device descends from it. It has been recalled 5 times.
- Decided
- Sep 21, 2021
- Review
- 14 days
- Class
- Class II
- Product code
- JAA
- Recalls
- 5
- Predicates
- 1
Its longest line of descent runs back 4 generations to K924593 (1992). 1 later device descends from it, 1 citing it directly.
- Root · 4 generations backK924593 Diagnost 76 Family*R/F Systems - Release 4.4Philips Medical Systems, Inc. · 1992 · Recalled
- 3 generations backK970640 Philips Easy DiagnostPhilips Medical Systems North America, Inc. · 1997 · Recalled
- 2 generations backK031535 Philips Easydiagnost ElevaPhilips Medical Systems North America Co. · 2003 · Recalled
- 1 generation backK173433 ProxiDiagnost N90Philips Medical Systems Dmc GmbH · 2018 · Recalled
- This deviceK212837 ProxiDiagnost N90Philips Medical Systems Dmc GmbH · 2021
- Descendant · cites it directly · 0 of its ownK233945 ProxiDiagnost N90 / Precision CRF (706110, 706400)Philips Medical Systems Dmc GmbH · 2024 · Recalled
Most influential descendants
Showing 1 of 1 · See all- K233945ProxiDiagnost N90 / Precision CRF (706110, 706400)Philips Medical Systems Dmc GmbH · 2024 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K924593 | Diagnost 76 Family*R/F Systems - Release 4.4 | Philips Medical Systems, Inc. | 1992 | 1 |
| −3 | K970640 | Philips Easy Diagnost | Philips Medical Systems North America, Inc. | 1997 | 5 |
| −2 | K031535 | Philips Easydiagnost Eleva | Philips Medical Systems North America Co. | 2003 | 15 |
| −1 | K173433 | ProxiDiagnost N90 | Philips Medical Systems Dmc GmbH | 2018 | 7 |
| 0 (this device) | K212837 | ProxiDiagnost N90 | Philips Medical Systems Dmc GmbH | 2021 | — |
| +1 | K233945 | ProxiDiagnost N90 / Precision CRF (706110, 706400) | Philips Medical Systems Dmc GmbH | 2024 | 2 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2024 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JAA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JAA device
- #1 K253103 Nexus DRF Digital X-ray Imaging Systemscore 13.2 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K173433 | ProxiDiagnost N90Summary page 4…Device Class: Class II Product Code: JAA; KPR Predicate Device Name ProxiDiagnost N90 (K173433, February 5, 2018) Device Legal Manufacturer Philips Medical Systems DMC GmbH Class… | 2018 |
| † | K203087 | CombiDiagnost R90 | 2020 |
| † | K202564 | DigitalDiagnost C90 | 2020 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K233945 | ProxiDiagnost N90 / Precision CRF (706110, 706400) | 2024 | 0 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Dec 15, 2023 | Class II | Z-1073-2024 | Software design | Issue 1: Mixed Images: The Radio Fluoroscopy (RF) viewer may also display a previous patients radiography (RAD) images when starting the next patient scan while the previous patient image export is still processing. If the issue occurs… |
| Dec 15, 2023 | Class II | Z-1072-2024 | Software design | Issue 1: Mixed Images: The Radio Fluoroscopy (RF) viewer may also display a previous patient s radiography (RAD) images when starting the next patient scan while the previous patient image export is still processing. If the issue occurs… |
| Sep 21, 2023 | Class II | Z-0280-2024 | Under Investigation by firm | Potential for units suspended on the ceiling to fail and fall. |
| Oct 21, 2022 | Class II | Z-1477-2023 | Component design/selection | Potential table stop due to a broken tabletop cable: On the ProxiDiagnost N90 table there is a cable located under the tabletop that is covered by a plastic sleeve which can crack and damage the cable. If the tabletop cable breaks, the… |
| May 19, 2021 | Class II | Z-1325-2022 | Radiation Control for Health and Safety Act | Following a system restart where the Table Height 2 (TH2) is the default setting and then switched to Wallstand VS2, operators will see an incorrect orientation of image on the first examination due to an issue in the firmware of the… |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 29 years and passes through 4 companies; a new generation was cleared every 6.2 years on median.
- 4 of the 4 ancestors have a recall of any class.
- Of its descendants, K233945 (Philips Medical Systems Dmc GmbH, 2024) has gone furthest, with 0 descendants of its own.
How does its category compare?
All JAA devicesJAA System, X-Ray, Fluoroscopic, Image-Intensified: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.
FDA decisions per year · JAA
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JAA
89in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JAA
4in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JAA
33in 2025
MAUDE reports naming product code JAA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 35 | 9,517 |
| 2008 | 6 | 18 | 21 | 9,484 |
| 2009 | 0 | — | 18 | 12,040 |
| 2010 | 1 | — | 6 | 5,803 |
| 2011 | 4 | 48 | 7 | 14,000 |
| 2012 | 1 | — | 2 | 11,684 |
| 2013 | 6 | 129 | 3 | 13,706 |
| 2014 | 6 | 276 | 1 | 10,265 |
| 2015 | 3 | 197 | 1 | 2,922 |
| 2016 | 2 | — | 7 | 35 |
| 2017 | 1 | — | 3 | 56 |
| 2018 | 3 | 30 | 1 | 36 |
| 2019 | 6 | 49 | 2 | 49 |
| 2020 | 4 | 39 | 2 | 39 |
| 2021 | 6 | 104 | 2 | 35 |
| 2022 | 1 | — | 5 | 34 |
| 2023 | 2 | — | 9 | 41 |
| 2024 | 3 | 89 | 2 | 25 |
| 2025 | 2 | — | 4 | 33 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
ProxiDiagnost N90 is a multi-functional general R/F system. It is suitable for all routine radiography and fluoroscopy exams, including specialist areas like angiography or pediatric work, excluding mammography.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K212837 · printed Nov 4, 2026
Cite this page
510(k) Report. “K212837: ProxiDiagnost N90.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K212837