Ivent 201 Portable Ventilator

K042468510(k) SpecialCleared Nov 17, 200465-day reviewClass II21 CFR 868.5895

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Versamed Medical Systems, Inc. · CBK Ventilator, Continuous, Facility Use

Cleared on Nov 17, 2004 as substantially equivalent to K021981 (Versamed, Ltd., 2003) and 1 other predicate after a 65-day review. Its family tree reaches back 4 generations to 1997. 41 of the 132 devices in its family, counting itself, have a Class I recall. 123 later devices descend from it.

Decided
Nov 17, 2004
Review
65 days
Class
Class II
Product code
CBK
Recalls
None
Predicates
2

Its longest line of descent runs back 4 generations to K962603 (1997). 8 ancestors in all, the oldest K943531 (1995). 123 later devices descend from it, 4 citing it directly. 41 of the 132 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2001: 1 other ancestor1999: 1 other ancestor1996: 1 other ancestor1995: 1 other ancestor2005: 1 descendant cleared2009: 5 descendants cleared, 1 with a Class I recall12008: 7 descendants cleared, 2 with a Class I recall22006: 4 descendants cleared, 1 with a Class I recall12010: 3 descendants cleared, 1 with a Class I recall12011: 12 descendants cleared, 8 with a Class I recall82015: 8 descendants cleared, 2 with a Class I recall22012: 13 descendants cleared, 5 with a Class I recall52014: 6 descendants cleared, 1 with a Class I recall12019: 8 descendants cleared, 3 with a Class I recall32016: 6 descendants cleared, 2 with a Class I recall22023: 3 descendants cleared, 1 with a Class I recall12007: 1 descendant cleared2017: 10 descendants cleared, 4 with a Class I recall42018: 2 descendants cleared2013: 10 descendants cleared, 4 with a Class I recall42026: 5 descendants cleared2024: 5 descendants cleared2021: 6 descendants cleared, 3 with a Class I recall32022: 1 descendant cleared2025: 3 descendants cleared2020: 4 descendants cleared, 3 with a Class I recall3K962603 · Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables · Masimo Corp. · 1997K973887 · Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables · Masimo Corp. · 1998K990966 · Masimo Set 2000 Pulse Oximeter, Masimo Lnop -Adt-Adult/Pediatric Disposable Sensor, Masimo Lnop -PDT-Pediatric/Small Dis · Masimo Corp. · 1999K021981 · Ivent 201 Portable Ventilator · Versamed, Ltd. · 20031995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 1 other ancestor3 generations back: 2 other ancestors 1 generation forward: 4 descendants, 2 with a Class I recall22 generations forward: 11 descendants, 5 with a Class I recall53 generations forward: 12 descendants, 4 with a Class I recall44 generations forward: 16 descendants, 4 with a Class I recall45 generations forward: 20 descendants, 5 with a Class I recall56 generations forward: 19 descendants, 6 with a Class I recall67 generations forward: 18 descendants, 8 with a Class I recall88 generations forward: 11 descendants, 1 with a Class I recall19 generations forward: 7 descendants, 4 with a Class I recall410 generations forward: 4 descendants, 2 with a Class I recall211 generations forward: 1 descendant K021981 · Ivent 201 Portable Ventilator · Versamed, Ltd. · 2003K990966 · Masimo Set 2000 Pulse Oximeter, Masimo Lnop -Adt-Adult/Pediatric Disposable Sensor, Masimo Lnop -PDT-Pediatric/Small Dis · Masimo Corp. · 1999K973887 · Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables · Masimo Corp. · 1998K962603 · Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables · Masimo Corp. · 19970+5+10
  1. Root · 4 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 3 generations backK973887 Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and…Masimo Corp. · 1998
  3. 2 generations backK990966 Masimo Set 2000 Pulse Oximeter, Masimo Lnop -Adt-Adult/Pediatric…Masimo Corp. · 1999
  4. 1 generation backK021981 Ivent 201 Portable VentilatorVersamed, Ltd. · 2003
  5. This deviceK042468 Ivent 201 Portable VentilatorVersamed Medical Systems, Inc. · 2004
  6. Descendant · cites it directly · 112 of its ownK052554 Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc. · 2005
  7. Descendant · 2 generations on · 87 of its ownK053270 IVENT 201Versamed Medical Systems, Inc. · 2006
  8. Descendant · 3 generations on · 86 of its ownK061627 Modification to I Vent 201Versamed Medical Systems, Inc. · 2006
  9. Descendant · 4 generations on · 61 of its ownK063404 Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB · 2007
  10. Descendant · 5 generations on · 37 of its ownK081842 Engstrom Carestation, Engstrom ProDatex-Ohmeda, Inc. · 2008

Showing 5 of 123 descendants. See all descendants

Descendants cleared per year

2005: 12006: 42007: 12008: 72009: 52010: 32011: 122012: 132013: 102014: 62015: 82016: 62017: 102018: 22019: 82020: 42021: 62022: 12023: 32024: 52025: 32026: 5
2005high 13 (2012) · low 1 (2005)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 123 · See all
  • K052554Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc. · 2005 · cites it directly112descendants
  • K053270IVENT 201Versamed Medical Systems, Inc. · 2006 · 2 generations on87descendants
  • K061627Modification to I Vent 201Versamed Medical Systems, Inc. · 2006 · 3 generations on86descendants
  • K063404Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB · 2007 · 4 generations on61descendants
  • K081842Engstrom Carestation, Engstrom ProDatex-Ohmeda, Inc. · 2008 · 5 generations on37descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K962603Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp.1997—
−3K973887Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and CablesMasimo Corp.1998—
−2K990966Masimo Set 2000 Pulse Oximeter, Masimo Lnop -Adt-Adult/Pediatric Disposable…Masimo Corp.1999—
−1K021981Ivent 201 Portable VentilatorVersamed, Ltd.2003—
0 (this device)K042468Ivent 201 Portable VentilatorVersamed Medical Systems, Inc.2004—
+1K052554Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc.2005—
+2K053270IVENT 201Versamed Medical Systems, Inc.2006—
+3K061627Modification to I Vent 201Versamed Medical Systems, Inc.2006—
+4K063404Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB2007—
+5K081842Engstrom Carestation, Engstrom ProDatex-Ohmeda, Inc.2008—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199610
199910
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
200641
200710
200872
200951
201031
2011128
2012135
2013104
201461
201582
201662
2017104
201820
201983
202043
202163
202210
202331
202450
202530
202650
FIG. 1 — Lineage of K042468, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

41 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CBK device

  1. #1 K252663 Inbentus Versatilescore 16.0 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K021981Ivent 201 Portable Ventilator
Summary page 2
…nistrative requirements Predicate Devices: The iVentTM 201 Portable Ventilator is substantially equivalent to: iVentTM 201 with pulse oximeter cleared under K021981 iVentTM 201 with remote alarm cable cleared under K01 1957 Performance Standards: No performance standards have been e…
Versamed, Ltd.2003—
*K011957Ivent 201 Portable Ventilator
Summary page 2
…VentTM 201 Portable Ventilator is substantially equivalent to: iVentTM 201 with pulse oximeter cleared under K021981 iVentTM 201 with remote alarm cable cleared under K01 1957 Performance Standards: No performance standards have been established for such devices under Sections 514 of the…
Versamed, Ltd.2001—

Also cleared against K021981: 3 other devices →

What descends from it? (123)

See all 123

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K052554Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc.2005112
K062267Oxylog 3000 Class IDrager Medical B.V.200620
K082724Newport HTS50 Ventilator with Dual Pac Battery SystemNewport Medical Instruments, Inc.20089
K090888Newport HT70 Family of Ventilators Class INewport Medical Instruments, Inc.20092

Has anything in its family been recalled? (41 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K090888Newport HT70 Family of VentilatorsNewport Medical Instruments, Inc. · 2009 · Cites it directly · ◆ in the 2009 descendants bar of FIG. 13 Class I recalls
  • K062267Oxylog 3000Drager Medical B.V. · 2006 · Cites it directly · ◆ in the 2006 descendants bar of FIG. 13 Class I recalls
  • K093261MOVESThornhill Research, Inc. · 2010 · 2 generations on · ◆ in the 2010 descendants bar of FIG. 12 Class I recalls
  • K082600Oxylog 2000 Plus System (Model 5705080), Oxylog 2000 Plus Basic Device (Model 5705082)Draeger Medical B.V. · 2008 · 2 generations on · ◆ in the 2008 descendants bar of FIG. 12 Class I recalls
  • K103625Oxylog 3000 Plus Workstation, Oxylog 3000 Plus Basic DeviceDraeger Medical Systems, Inc. · 2011 · 2 generations on · ◆ in the 2011 descendants bar of FIG. 14 Class I recalls
  • K141595O-Two E700,O-Two E600,O-Two E500O-Two Medical Technologies, Inc. · 2015 · 2 generations on · ◆ in the 2015 descendants bar of FIG. 13 Class I recalls
  • K111146Newport HT70 VentilatorNewport Medical Instruments, Inc. · 2011 · 2 generations on · ◆ in the 2011 descendants bar of FIG. 14 Class I recalls
  • K072885Carina System, Model 8419350; Carina Basic Device, Model 5704110Draeger Medical AG & Co. KG · 2008 · 3 generations on · ◆ in the 2008 descendants bar of FIG. 11 Class I recall
  • K120670Hamilton-T1Hamilton Medical AG · 2012 · 3 generations on · ◆ in the 2012 descendants bar of FIG. 11 Class I recall
  • K181216Hamilton-T1, Hamilton-C1Hamilton Medical AG · 2019 · 3 generations on · ◆ in the 2019 descendants bar of FIG. 15 Class I recalls
  • K153046Hamilton-MR1Hamilton Medical AG · 2016 · 3 generations on · ◆ in the 2016 descendants bar of FIG. 11 Class I recall
  • K111610Trilogy Series Ventilator with OximetryRespironics, Inc. · 2011 · 4 generations on · ◆ in the 2011 descendants bar of FIG. 12 Class I recalls

Nearest 12 of 41 shown.

What does this lineage say?

  • The line of descent spans 7 years and passes through 3 companies; a new generation was cleared every 1.4 years on median.
  • None of the 8 ancestors has a recall.
  • Of its descendants, K052554 (Versamed Medical Systems, Inc., 2005) has gone furthest, with 112 descendants of its own.
  • 3 other devices also cite its predicate K021981.

How does its category compare?

All CBK devices

CBK Ventilator, Continuous, Facility Use: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CBK

4in 2025

2007: 112008: 182009: 122010: 142011: 132012: 172013: 52014: 52015: 72016: 42017: 62018: 42019: 82020: 52021: 62023: 52024: 92025: 42026 (partial year): 3
2007high 18 (2008) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CBK

163in 2025

2007: 142 days median2008: 115 days median2009: 122 days median2010: 150 days median2011: 192 days median2012: 207 days median2013: 277 days median2014: 439 days median2015: 266 days median2016: 323 days median2017: 280 days median2018: 183 days median2019: 435 days median2020: 176 days median2021: 267 days median2023: 309 days median2024: 203 days median2025: 163 days median2026 (partial year): 235 days median
2007high 439 (2014) · low 115 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CBK

14in 2024

2007: 172008: 232009: 82010: 92011: 122012: 2, 1 Class I2013: 5, 2 Class I2014: 5, 4 Class I2015: 6, 4 Class I2016: 4, 1 Class I2017: 12018: 3, 3 Class I2019: 14, 13 Class I2020: 42021: 21, 19 Class I2022: 8, 4 Class I2023: 4, 3 Class I2024: 14, 14 Class I2026 (partial year): 15, 13 Class I
2007high 23 (2008) · low 0 (2025)2026

Class I (81 since 2007) Class II/III not classified

Adverse event reports per year · CBK

13,991in 2025

2007: 1,5312008: 1,9332009: 1,7662010: 1,7992011: 1,8772012: 5,5092013: 7,9212014: 7,6002015: 11,8762016: 16,0562017: 14,4512018: 9,8492019: 9,1002020: 11,0962021: 13,3222022: 15,9742023: 24,9282024: 20,3362025: 13,991
2007high 24,928 (2023) · low 1,531 (2007)2025

MAUDE reports naming product code CBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711142171,531
200818115231,933
20091212281,766
20101415091,799
201113192121,877
2012172072 (1)5,509
201352775 (2)7,921
201454395 (4)7,600
201572666 (4)11,876
201643234 (1)16,056
20176280114,451
201841833 (3)9,849
2019843514 (13)9,100
20205176411,096
2021626721 (19)13,322
20220—8 (4)15,974
202353094 (3)24,928
2024920314 (14)20,336
20254163013,991
2026323515 (13)—

What is it indicated for?

The iVent 201 is a portable, computer controlled, electrically powered ventilator intended to provide continuous or intermittent ventilatory support for the care of individuals who require mechanical ventilation. Specifically, the ventilator is applicable for adult and pediatric patients weighing at least 10 kg (22 lb.), who require the following general modes of ventilatory support, as prescribed by an attending physician: · Assist/Control (Pressure…

Read the full statement (140 words)

The iVent 201 is a portable, computer controlled, electrically powered ventilator intended to provide continuous or intermittent ventilatory support for the care of individuals who require mechanical ventilation. Specifically, the ventilator is applicable for adult and pediatric patients weighing at least 10 kg (22 lb.), who require the following general modes of ventilatory support, as prescribed by an attending physician:

· Assist/Control (Pressure Controlled or Volume Controlled)

* SIMV (Pressure Controlled or Volume Controlled)

* CPAP/PSV

The iVent 201 ventilator with Non-invasive Pulse Oximeter is suitable for intra-hospital use, home and alternate-site use, transport and emergency use. The Non-invasive Pulse Oximeter is intended for non-invasive monitoring of oxygen saturation and pulse rate.

The iVent 201 ventilator is a restricted medical device intended for use by qualified, trained personnel under the direction of a physician and within the technical specification limits.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K042468: Ivent 201 Portable Ventilator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K042468

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026