510(k) · Cleared
ClearedTesera-K SC System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Kyocera Medical Technologies, Inc. · OVE Intervertebral Fusion Device With Integrated Fixation, Cervical
Cleared on Dec 22, 2022 as substantially equivalent to K212853 (Eminent Spine, LLC, 2021) and 3 other predicates after an 83-day review. Its family tree reaches back 24 generations to 1984. 1 of the 424 devices in its family, counting itself, has a Class I recall. 5 later devices descend from it.
- Decided
- Dec 22, 2022
- Review
- 83 days
- Class
- Class II
- Product code
- OVE
- Recalls
- None
- Predicates
- 4
Its longest line of descent runs back 24 generations to K841189 (1984). 418 ancestors in all, the oldest K792352 (1979). 5 later devices descend from it, 2 citing it directly. 1 of the 424 devices in this family, counting this one, has a Class I recall.
- Root · 24 generations backK841189 Oec/Rezaian Spinal FixatorOrthopedic Equipment Co., Inc. · 1984
- 20 generations between
- 3 generations backK190546 NEXXT MATRIXX Stand Alone Cervical SystemNexxt Spine, LLC · 2019
- 2 generations backK193000 Hexanium® ACIFSpinevision, S.A.S. · 2020
- 1 generation backK211111 SureMAX-SA Cervical Standalone SystemAdditive Implants, Inc. · 2021
- This deviceK223105 Tesera-K SC SystemKyocera Medical Technologies, Inc. · 2022
- Descendant · cites it directly · 3 of its ownK231766 Skyway Anterior Cervical Plate SystemKyocera Medical Technologies Inc. (KMTI) · 2023
- Descendant · 2 generations on · 2 of its ownK243015 Skyway Anterior Cervical Plate SystemKyocera Medical Technologies, Inc. · 2024
- Descendant · 3 generations on · 1 of its ownK250486 Skyway Anterior Cervical Plate SystemKyocera Medical Technologies Inc. (KMTI) · 2025
- Descendant · 4 generations on · 0 of its ownK261451 ZSAlign Cervical Interbody SystemZSFab, Inc. · 2026
- Descendant · cites it directly · 0 of its ownK242928 Tesera-k SC SystemKyocera Medical Technologies, Inc. · 2025
Show all 24 generations
- Root · 24 generations backK841189 Oec/Rezaian Spinal FixatorOrthopedic Equipment Co., Inc. · 1984
- 23 generations backK990148 Stackable Cage SystemDepuy Motech Acromed · 1999
- 22 generations backK003043 Surgical Titanium Mesh SystemDepuyacromed · 2001
- 21 generations backK022793 Tetris Spinal ImplantSignus Medical, LLC · 2003
- 20 generations backK031757 Peek Tetris Spinal ImplantSignus Medical, LLC · 2003
- 19 generations backK041888 Curved Peek Tetris Spinal ImplantSignus Medizintechnik GmbH · 2004
- 18 generations backK042930 Spacevision Cage SystemSpine Vision, Inc. · 2004
- 17 generations backK062759 Paramount VBR SystemInnovative Spinal Technologies, Inc. · 2007
- 16 generations backK072120 Paramount Intervertebral Body Fusion DeviceInnovative Spinal Technologies, Inc. · 2007
- 15 generations backK073291 Capstone Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2008
- 14 generations backK094025 Crescent Spinal SystemMedtronic Sofamor Danek · 2010
- 13 generations backK110543 Crescent (R) Spinal System TitaniumMedtronic Sofamor Danek USA, Inc. · 2011
- 12 generations backK121683 Acculif TL CageCoalign Innovations, Inc. · 2012
- 11 generations backK123752 Acculif TL and PL CageCoalign Innovations, Inc. · 2013
- 10 generations backK132505 Acculif TL and PL CageCoalign Innovations, Inc. · 2013 · Recalled
- 9 generations backK141217 Acculif TL and PL CageStryker Corporation · 2014 · Recalled
- 8 generations backK143163 AVS® AL and ALign PEEK Spacers, AVS® PL and UniLIF PEEK Spacers…Stryker Corporation · 2015
- 7 generations backK143616 AccuLIF TL and PL CageStryker Corporation · 2015 · Recalled
- 6 generations backK152304 Tritanium PL CageStryker · 2015 · Recalled
- 5 generations backK160125 Cascadia Interbody SystemK2m · 2016
- 4 generations backK171140 Matrixx SystemNexxt Spine, LLC · 2017
- 3 generations backK190546 NEXXT MATRIXX Stand Alone Cervical SystemNexxt Spine, LLC · 2019
- 2 generations backK193000 Hexanium® ACIFSpinevision, S.A.S. · 2020
- 1 generation backK211111 SureMAX-SA Cervical Standalone SystemAdditive Implants, Inc. · 2021
- This deviceK223105 Tesera-K SC SystemKyocera Medical Technologies, Inc. · 2022
Class I recalls in this family
- K073202 Ardis Spacer8 generations back · 2008
Most influential descendants
Showing 5 of 5 · See all- K231766Skyway Anterior Cervical Plate SystemKyocera Medical Technologies Inc. (KMTI) · 2023 · cites it directly3descendants
- K243015Skyway Anterior Cervical Plate SystemKyocera Medical Technologies, Inc. · 2024 · 2 generations on2descendants
- K250486Skyway Anterior Cervical Plate SystemKyocera Medical Technologies Inc. (KMTI) · 2025 · 3 generations on1descendant
- K261451ZSAlign Cervical Interbody SystemZSFab, Inc. · 2026 · 4 generations on0descendants
- K242928Tesera-k SC SystemKyocera Medical Technologies, Inc. · 2025 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −24 | K841189 | Oec/Rezaian Spinal Fixator | Orthopedic Equipment Co., Inc. | 1984 | — |
| −23 | K990148 | Stackable Cage System | Depuy Motech Acromed | 1999 | — |
| −22 | K003043 | Surgical Titanium Mesh System | Depuyacromed | 2001 | — |
| −21 | K022793 | Tetris Spinal Implant | Signus Medical, LLC | 2003 | — |
| −20 | K031757 | Peek Tetris Spinal Implant | Signus Medical, LLC | 2003 | — |
| −19 | K041888 | Curved Peek Tetris Spinal Implant | Signus Medizintechnik GmbH | 2004 | — |
| −18 | K042930 | Spacevision Cage System | Spine Vision, Inc. | 2004 | — |
| −17 | K062759 | Paramount VBR System | Innovative Spinal Technologies, Inc. | 2007 | — |
| −16 | K072120 | Paramount Intervertebral Body Fusion Device | Innovative Spinal Technologies, Inc. | 2007 | — |
| −15 | K073291 | Capstone Spinal System | Medtronic Sofamor Danek USA, Inc. | 2008 | — |
| −14 | K094025 | Crescent Spinal System | Medtronic Sofamor Danek | 2010 | — |
| −13 | K110543 | Crescent (R) Spinal System Titanium | Medtronic Sofamor Danek USA, Inc. | 2011 | — |
| −12 | K121683 | Acculif TL Cage | Coalign Innovations, Inc. | 2012 | — |
| −11 | K123752 | Acculif TL and PL Cage | Coalign Innovations, Inc. | 2013 | — |
| −10 | K132505 | Acculif TL and PL Cage | Coalign Innovations, Inc. | 2013 | 3 |
| −9 | K141217 | Acculif TL and PL Cage | Stryker Corporation | 2014 | 3 |
| −8 | K143163 | AVS® AL and ALign PEEK Spacers, AVS® PL and UniLIF PEEK Spacers, AVS® TL PEEK… | Stryker Corporation | 2015 | — |
| −7 | K143616 | AccuLIF TL and PL Cage | Stryker Corporation | 2015 | 4 |
| −6 | K152304 | Tritanium PL Cage | Stryker | 2015 | 1 |
| −5 | K160125 | Cascadia Interbody System | K2m | 2016 | — |
| −4 | K171140 | Matrixx System | Nexxt Spine, LLC | 2017 | — |
| −3 | K190546 | NEXXT MATRIXX Stand Alone Cervical System | Nexxt Spine, LLC | 2019 | — |
| −2 | K193000 | Hexanium® ACIF | Spinevision, S.A.S. | 2020 | — |
| −1 | K211111 | SureMAX-SA Cervical Standalone System | Additive Implants, Inc. | 2021 | — |
| 0 (this device) | K223105 | Tesera-K SC System | Kyocera Medical Technologies, Inc. | 2022 | — |
| +1 | K231766 | Skyway Anterior Cervical Plate System | Kyocera Medical Technologies Inc. (KMTI) | 2023 | — |
| +2 | K243015 | Skyway Anterior Cervical Plate System | Kyocera Medical Technologies, Inc. | 2024 | — |
| +3 | K250486 | Skyway Anterior Cervical Plate System | Kyocera Medical Technologies Inc. (KMTI) | 2025 | — |
| +4 | K261451 | ZSAlign Cervical Interbody System | ZSFab, Inc. | 2026 | — |
| +1 | K242928 | Tesera-k SC System | Kyocera Medical Technologies, Inc. | 2025 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1979 | 1 | 0 |
| 1980 | 1 | 0 |
| 1990 | 1 | 0 |
| 1992 | 3 | 0 |
| 1993 | 1 | 0 |
| 1995 | 1 | 0 |
| 1996 | 6 | 0 |
| 1997 | 1 | 0 |
| 1998 | 3 | 0 |
| 1999 | 6 | 0 |
| 2000 | 4 | 0 |
| 2001 | 13 | 0 |
| 2002 | 11 | 0 |
| 2003 | 18 | 0 |
| 2004 | 29 | 0 |
| 2005 | 24 | 0 |
| 2006 | 15 | 0 |
| 2007 | 21 | 0 |
| 2008 | 50 | 1 |
| 2009 | 32 | 0 |
| 2010 | 20 | 0 |
| 2011 | 34 | 0 |
| 2012 | 23 | 0 |
| 2013 | 19 | 0 |
| 2014 | 25 | 0 |
| 2015 | 10 | 0 |
| 2016 | 9 | 0 |
| 2017 | 7 | 0 |
| 2018 | 2 | 0 |
| 2019 | 1 | 0 |
| 2020 | 2 | 0 |
| 2021 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2023 | 1 | 0 |
| 2024 | 1 | 0 |
| 2025 | 2 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new OVE device
- #1 K241846 E3D™-C Interbody Systemscore 32.1 · 32 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K212853 | Cervical Stand-Alone SystemSummary page 5…anufacturer Product Predicate Number Code Type K212853 Cervical Stand-Alone System Eminent Spine, LLC OVE Primary K211111 SureMAX-SA Cervi… | 2021 |
| * | K211111 | SureMAX-SA Cervical Standalone SystemSummary page 5…Code Type K212853 Cervical Stand-Alone System Eminent Spine, LLC OVE Primary K211111 SureMAX-SA Cervical Standalone System Additive Implants, Inc. OVE Additional K173077 Cavetto®-SA C… | 2021 |
| * | K173077 | Cavetto-SA Cervical Cage SystemSummary page 5…nt Spine, LLC OVE Primary K211111 SureMAX-SA Cervical Standalone System Additive Implants, Inc. OVE Additional K173077 Cavetto®-SA Cervical Cage System Neurostructures, Inc OVE Additional K153250 Tesera SC Sta… | 2018 |
| * | K153250 | Renovis Tesera SC Stand-alone Anterior Cervical Fusion (ACF) SystemSummary page 5…Implants, Inc. OVE Additional K173077 Cavetto®-SA Cervical Cage System Neurostructures, Inc OVE Additional K153250 Tesera SC Stand-Alone Cervical Fusion (ACF) Renovis Surgical Technologies, Inc. OVE, ODP Additional K212980 Tesera-k ALIF… | 2016 |
| † | K212980 | Tesera-k ALIF System | 2022 |
What descends from it? (5)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (1 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K073202Ardis SpacerAbbott Spine, Inc. · 2008 · 8 generations back · ◆ in the 2008 ancestors bar of FIG. 11 Class I recall
What does this lineage say?
- The line of descent spans 38 years and passes through 17 companies; a new generation was cleared every 11 months on median.
- 49 of the 418 ancestors have a recall of any class; 1 has a Class I recall.
- Of its descendants, K231766 (Kyocera Medical Technologies Inc. (KMTI), 2023) has gone furthest, with 3 descendants of its own.
- 4 other devices also cite its predicate K212853.
How does its category compare?
All OVE devicesOVE Intervertebral Fusion Device With Integrated Fixation, Cervical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.
FDA decisions per year · OVE
10in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · OVE
105in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · OVE
2in 2021
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · OVE
132in 2025
MAUDE reports naming product code OVE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 0 |
| 2008 | 4 | 131 | 0 | 0 |
| 2009 | 1 | — | 0 | 0 |
| 2010 | 4 | 210 | 0 | 2 |
| 2011 | 8 | 139 | 0 | 19 |
| 2012 | 7 | 125 | 0 | 59 |
| 2013 | 5 | 71 | 1 | 250 |
| 2014 | 11 | 168 | 1 | 150 |
| 2015 | 12 | 113 | 1 | 173 |
| 2016 | 15 | 149 | 1 | 145 |
| 2017 | 9 | 100 | 1 | 134 |
| 2018 | 7 | 105 | 0 | 210 |
| 2019 | 7 | 87 | 0 | 169 |
| 2020 | 13 | 149 | 0 | 162 |
| 2021 | 10 | 93 | 2 | 186 |
| 2022 | 10 | 144 | 0 | 200 |
| 2023 | 16 | 97 | 0 | 148 |
| 2024 | 6 | 56 | 0 | 142 |
| 2025 | 10 | 105 | 0 | 132 |
| 2026 | 13 | 66 | 0 | — |
What is it indicated for?
The KMTI Tesera-K SC System is indicated for intervertebral body fusion procedures in skeletally mature patients with cervical degenerative disc disease at one or two levels from C2-T1. KMTI Tesera-K SC System implants are to be used with autogenous bone graft. Patients should be skeletally mature and have at least six weeks of non-operative treatment prior to implantation. The KMTI Tesera-K SC System is a stand-alone system when used with the locking…
Read the full statement (147 words)
The KMTI Tesera-K SC System is indicated for intervertebral body fusion procedures in skeletally mature patients with cervical degenerative disc disease at one or two levels from C2-T1. KMTI Tesera-K SC System implants are to be used with autogenous bone graft. Patients should be skeletally mature and have at least six weeks of non-operative treatment prior to implantation.
The KMTI Tesera-K SC System is a stand-alone system when used with the locking bolt and bone screws provided and requires no additional supplemental fixation. When used as a stand-alone system, the cages require the use of two (2) bone screws and the locking bolt.
When used without the locking bolt and two screws, the KMTI Tesera-K SC System is a non-standalone system and requires additional supplemental fixation cleared by the FDA for use in the cervical spine to augment stability and may only be used at one level.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K223105 · printed Nov 4, 2026
Cite this page
510(k) Report. “K223105: Tesera-K SC System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K223105
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026