510(k) · Cleared
ClearedMayfield-Acciss Workstation
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Nomos Corp. · HAW Neurological Stereotaxic Instrument
Cleared on Apr 30, 1996 as substantially equivalent to K911783 (I.S.G. Technologies, Inc., 1994) and 2 other predicates after a 158-day review. Its family tree reaches back 1 generation to 1985. 15 later devices descend from it.
- Decided
- Apr 30, 1996
- Review
- 158 days
- Class
- Class II
- Product code
- HAW
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 1 generation to K851659 (1985). 3 ancestors in all. 15 later devices descend from it, 5 citing it directly.
- Root · 1 generation backK851659 Skull Mounted Stereotactic Surgical DeviceMedco Products, Co., Inc. · 1985
- This deviceK955397 Mayfield-Acciss WorkstationNomos Corp. · 1996
- Descendant · cites it directly · 10 of its ownK981424 Nomos Bat Ultrasound Localization and Positioning SystemNomos Corp. · 1998
- Descendant · 2 generations on · 4 of its ownK032100 I-BEAMComputerized Medical Systems, Inc. · 2003
- Descendant · 2 generations on · 3 of its ownK042110 BeamcathBeampoint AB · 2005
- Descendant · 2 generations on · 3 of its ownK041937 RestituResonant Medical, Inc. · 2004
- Descendant · 3 generations on · 2 of its ownK111332 Clarity Obp SystemElekta, Ltd. · 2012
Showing 5 of 15 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 15 · See all- K981424Nomos Bat Ultrasound Localization and Positioning SystemNomos Corp. · 1998 · cites it directly10descendants
- K032100I-BEAMComputerized Medical Systems, Inc. · 2003 · 2 generations on4descendants
- K042110BeamcathBeampoint AB · 2005 · 2 generations on3descendants
- K041937RestituResonant Medical, Inc. · 2004 · 2 generations on3descendants
- K111332Clarity Obp SystemElekta, Ltd. · 2012 · 3 generations on2descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K851659 | Skull Mounted Stereotactic Surgical Device | Medco Products, Co., Inc. | 1985 | — |
| 0 (this device) | K955397 | Mayfield-Acciss Workstation | Nomos Corp. | 1996 | — |
| +1 | K981424 | Nomos Bat Ultrasound Localization and Positioning System | Nomos Corp. | 1998 | — |
| +2 | K032100 | I-BEAM | Computerized Medical Systems, Inc. | 2003 | — |
| +2 | K042110 | Beamcath | Beampoint AB | 2005 | — |
| +2 | K041937 | Restitu | Resonant Medical, Inc. | 2004 | — |
| +3 | K111332 | Clarity Obp System | Elekta, Ltd. | 2012 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1992 | 1 | 0 |
| 1994 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1998 | 2 | 0 |
| 1999 | 3 | 0 |
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
| 2005 | 2 | 0 |
| 2008 | 1 | 0 |
| 2012 | 2 | 0 |
| 2013 | 1 | 0 |
| 2014 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HAW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HAW device
- #1 K253856 Geniant Cranial (Navigated Neurosurgical…score 15.0 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K911783 | Allegro Viewing WandSummary page 1…ident, Administration and Regulatory Affairs NOMOS Corporation 2591 Wexford Bayne Road Sewickley, PA 15143 ll. Name of predicate device(s): ISG Allegro Viewing Wand (K911783) Pelorus Arc Carrier (K851659A) CORITechs CORITaxic I Workstation (K915791) Cordis Micra Microosurgical Instruments (K862971) -… | 1994 |
| * | K851659 | Skull Mounted Stereotactic Surgical DeviceSummary page 1…latory Affairs NOMOS Corporation 2591 Wexford Bayne Road Sewickley, PA 15143 ll. Name of predicate device(s): ISG Allegro Viewing Wand (K911783) Pelorus Arc Carrier (K851659A) CORITechs CORITaxic I Workstation (K915791) Cordis Micra Microosurgical Instruments (K862971) - for use of Titanium in contact… | 1985 |
| * | K915791 | Coritaxic Multi-Modal Stereotaxi WorkstationSummary page 1…d Bayne Road Sewickley, PA 15143 ll. Name of predicate device(s): ISG Allegro Viewing Wand (K911783) Pelorus Arc Carrier (K851659A) CORITechs CORITaxic I Workstation (K915791) Cordis Micra Microosurgical Instruments (K862971) - for use of Titanium in contact with Brain Tissue l1l. Classification: Neu… | 1992 |
| † | K862971 | Micra Microsurgical Instruments | 1986 |
What descends from it? (15)
See all 155 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K981424 | Nomos Bat Ultrasound Localization and Positioning System | 1998 | 10 |
| K982244 | Mayfield Acciss Optical System | 1998 | 2 |
| K992843 | The Mayfield / Acciss System with Windows NT for Cranial Surgery, the Mayfield / Optical… | 1999 | 0 |
| K991636 | Elekta Stereotactic Guide | 1999 | 0 |
| K991267 | Spine Applications for the Mayfield/Acciss Operating Arm and Optical Acciss Systems… | 1999 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All HAW devicesHAW Neurological Stereotaxic Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · HAW
9in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HAW
163in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HAW
2in 2025
Class I (9 since 2007) Class II/III not classified
Adverse event reports per year · HAW
3,425in 2025
MAUDE reports naming product code HAW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 15 | 107 | 2 | 49 |
| 2008 | 12 | 112 | 10 | 53 |
| 2009 | 8 | 221 | 6 | 96 |
| 2010 | 6 | 138 | 28 | 299 |
| 2011 | 4 | 66 | 5 | 1,725 |
| 2012 | 8 | 178 | 4 | 986 |
| 2013 | 3 | 172 | 6 (1) | 1,290 |
| 2014 | 5 | 238 | 5 | 1,606 |
| 2015 | 10 | 232 | 3 | 1,767 |
| 2016 | 9 | 175 | 5 | 1,828 |
| 2017 | 7 | 226 | 2 | 3,505 |
| 2018 | 6 | 112 | 2 (2) | 4,439 |
| 2019 | 10 | 147 | 4 (1) | 6,062 |
| 2020 | 5 | 88 | 1 | 3,480 |
| 2021 | 9 | 168 | 4 (2) | 2,827 |
| 2022 | 7 | 128 | 1 | 1,929 |
| 2023 | 14 | 142 | 4 (1) | 2,510 |
| 2024 | 7 | 107 | 2 (2) | 3,755 |
| 2025 | 9 | 163 | 2 | 3,425 |
| 2026 | 5 | 162 | 6 | — |
What is it indicated for?
ACCISS is to be used both for guidance and localization in open craniotomies and for surgeries which are traditionally performed with a stereotactic apparatus, such as biopsies, thalamotomies and electrode implants. The system may also be used to review medical images in a neurosurgical context.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K955397 · printed Nov 4, 2026
Cite this page
510(k) Report. “K955397: Mayfield-Acciss Workstation.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K955397
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026