510(k) Report

510(k) · Cleared

Recalled · Class II · 2015

Philips Integris V5000 and BV5000

K973482510(k) TraditionalCleared Nov 10, 199756-day reviewClass II21 CFR 892.1600Recalls 4

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Philips Medical Systems North America, Inc. · IZI System, X-Ray, Angiographic

Cleared on Nov 10, 1997 as substantially equivalent to K910370 (Philips Medical Systems, Inc., 1991) after a 56-day review. Its family tree reaches back 1 generation to 1991. 1 later device descends from it. It has been recalled 4 times.

Decided
Nov 10, 1997
Review
56 days
Class
Class II
Product code
IZI
Recalls
4
Predicates
1

Its longest line of descent runs back 1 generation to K910370 (1991). 1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2010: 1 descendant clearedK910370 · Philips Integris V3000 and V4000 · Philips Medical Systems, Inc. · 19911990200020102020
Descendants, by generation 1 generation forward: 1 descendant K910370 · Philips Integris V3000 and V4000 · Philips Medical Systems, Inc. · 19910
  1. Root · 1 generation backK910370 Philips Integris V3000 and V4000Philips Medical Systems, Inc. · 1991
  2. This deviceK973482 Philips Integris V5000 and BV5000Philips Medical Systems North America, Inc. · 1997
  3. Descendant · cites it directly · 0 of its ownK092713 Spectre Wireless Encrypted Footswitch and Hand Switch SystemTransamerican Medical Imaging · 2010 · Recalled

Most influential descendants

Showing 1 of 1 · See all
  • K092713Spectre Wireless Encrypted Footswitch and Hand Switch SystemTransamerican Medical Imaging · 2010 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K910370Philips Integris V3000 and V4000Philips Medical Systems, Inc.1991—
0 (this device)K973482Philips Integris V5000 and BV5000Philips Medical Systems North America, Inc.1997—
+1K092713Spectre Wireless Encrypted Footswitch and Hand Switch SystemTransamerican Medical Imaging20101

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
FIG. 1 — Lineage of K973482, 1991–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IZI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IZI device

  1. #1 K230727 SPY Portable Handheld Imaging (SPY-PHI) Systemscore 23.2 · 20 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K910370Philips Integris V3000 and V4000
Summary page 1
…tion name: Angiographic X-ray system, 21 CFR 892.1600 Class I1 (90 1Z]) Common/Usual name: Angiographic x-ray system Predicate Device(s): Philips Integris V3000 ( Re.: K910370) Intended use: The Philips INTEGRIS V5000 and BV5000 system family is intended for use in dedicated vascular and neurovascular…
Philips Medical Systems, Inc.1991—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K092713Spectre Wireless Encrypted Footswitch and Hand Switch SystemTransamerican Medical Imaging20100

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Nov 3, 2015Class IIZ-0722-2016Device DesignThe use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
Nov 3, 2015Class IIZ-0723-2016Device DesignThe use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
Nov 3, 2015Class IIZ-0724-2016Device DesignThe use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
Nov 3, 2015Class IIZ-0725-2016Device DesignThe use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K092713 (Transamerican Medical Imaging, 2010) has gone furthest, with 0 descendants of its own.

How does its category compare?

All IZI devices

IZI System, X-Ray, Angiographic: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · IZI

2in 2025

2007: 72008: 62009: 22010: 22011: 42012: 12013: 12014: 42016: 12017: 22018: 22019: 22020: 12021: 12022: 12023: 32024: 22025: 22026 (partial year): 2
2007high 7 (2007) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IZI

81in 2023

2007: 28 days median2008: 68 days median2011: 104 days median2014: 111 days median2023: 81 days median
2007high 111 (2014) · low 28 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IZI

1in 2021

2007: 62008: 522009: 182010: 112011: 62012: 62013: 62014: 52015: 142016: 72017: 12018: 22019: 22020: 22021: 12026 (partial year): 1
2007high 52 (2008) · low 0 (2022)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IZI

2,171in 2025

2007: 922008: 1012009: 1322010: 2522011: 3772012: 772013: 582014: 1232015: 362016: 1022017: 882018: 492019: 302020: 142021: 292022: 2652023: 1,2042024: 1,3322025: 2,171
2007high 2,171 (2025) · low 14 (2020)2025

MAUDE reports naming product code IZI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007728692
200866852101
20092—18132
20102—11252
201141046377
20121—677
20131—658
201441115123
20150—1436
20161—7102
20172—188
20182—249
20192—230
20201—214
20211—129
20221—0265
202338101,204
20242—01,332
20252—02,171
20262—1—

What is it indicated for?

The Philips INTEGRIS V5000 and BV5000 system family is intended for use in

dedicated vascular and neurovascular applications, including diagnostic and

interventional procedures.

This includes, e.g., peripheral, cerebral, thoracic and abdominal angiography as well

as PTA’s stent placements, embolisations, and thrombolysis. The systems are also

intended for use in mixed cardiac/vascular/neuro applications and also non vascular

interventions.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K973482: Philips Integris V5000 and BV5000.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K973482

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.