510(k) Report

510(k) · Cleared

Recalled · Class I · 2017

Heartstart MRX Monitor/Defibrillator

K062233510(k) SpecialCleared Nov 22, 2006112-day reviewClass III21 CFR 870.5310Recalls 11 (2 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Philips Medical Systems North America, Inc. · MKJ Automated External Defibrillators (Non-Wearable)

Cleared on Nov 22, 2006 as substantially equivalent to K031187 (Philips Medical Systems, 2003) and 1 other predicate after a 112-day review. Its family tree reaches back 1 generation to 2003. 3 of the 3 devices in its family, counting itself, have a Class I recall. It has been recalled 11 times, including 2 Class I recalls.

Decided
Nov 22, 2006
Review
112 days
Class
Class III
Product code
MKJ
Recalls
11 (2 Class I)
Predicates
2

Its longest line of descent runs back 1 generation to K031187 (2003). 2 ancestors in all. No later device cites it as a predicate yet. 3 of the 3 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year cleared 2005: 1 other ancestor, 1 with a Class I recall1K031187 · Heartstart MRX, Model M3535A · Philips Medical Systems · 2003 · Class I recall20002002200420062008
Other ancestors, by generation 1 generation back: 1 other ancestor, 1 with a Class I recall1 K031187 · Heartstart MRX, Model M3535A · Philips Medical Systems · 2003 · Class I recall0
  1. Root · 1 generation backK031187 Heartstart MRX, Model M3535APhilips Medical Systems · 2003 · Recalled (Class I)
  2. This deviceK062233 Heartstart MRX Monitor/DefibrillatorPhilips Medical Systems North America, Inc. · 2006

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K031187Heartstart MRX, Model M3535APhilips Medical Systems2003Class I
0 (this device)K062233Heartstart MRX Monitor/DefibrillatorPhilips Medical Systems North America, Inc.2006—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200511
FIG. 1 — Lineage of K062233, 2003–2006Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K031187Heartstart MRX, Model M3535A
Summary page 1
…Cardiopulmonary Resuscitation Aid 3. The new device is substantially equivalent to the previously cleared HeartStart MRx Monitor/Defibrillator software cleared under K031187 and K051134. 4. The modification is a change that provides network connectivity via the Philips IntelliVue Network. 5. Th…
Philips Medical Systems2003Class I
*K051134Heartstart MRX with Q-CPR Option, Models M3535A or M3536A
Summary page 1
…Resuscitation Aid 3. The new device is substantially equivalent to the previously cleared HeartStart MRx Monitor/Defibrillator software cleared under K031187 and K051134. 4. The modification is a change that provides network connectivity via the Philips IntelliVue Network. 5. The new device ha…
Philips Medical Systems2005Class I

Also cleared against K031187: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (3 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 28, 2017Class IIZ-0278-2018Nonconforming Material/ComponentPhilips MRx devices have an EtCO2 module that may contain contamination; this contamination (will/may) cause the device to be unable to display the EtCO2 or CO2 waveform (capnogram).
Jul 17, 2017Class IIZ-0348-2018Device DesignIssue with ECG out cables. When a Philips monitor/defibrillator is receiving an ECG signal from an auxiliary bedside monitor via a sync cable or ECG out cable, the following can occur if the monitor/defibrillator experiences interference…
Jul 12, 2017Class IZ-0489-2018Nonconforming Material/ComponentAffected units may have a defective component that is intended to protect the internal circuitry from high voltages during shock delivery. The defective component may also prevent delivery of shocks in AED mode.
Feb 24, 2017Class IZ-1417-2017Device DesignHeartStart MRx Monitor/Defibrillator may may exhibit abnormal behavior when operating using a single battery as the sole source of power may fail to deliver therapy or monitoring
Aug 26, 2016Class IIZ-2842-2016Device DesignThe handle can separate from the MRx housing due to breakage of mounts on the rear case.
Apr 14, 2016Class IIZ-1612-2016Employee errorMRx monitor/defibrillators could fail to charge because the therapy printed circuit board may have been loaded with an incorrect electronic component.
Oct 14, 2015Class IIZ-0320-2016Software designThe following MRx software issue has been identified: MRx model M3535A with software version F.03.06 and earlier, and model M3536A with version T.00.05 and earlier may stop the automated Ready-For-Use (RFU) test in an abnormal state when…
Dec 23, 2014Class IIZ-0219-2016Software designMRx monitor/defibrillator could reboot at an indeterminate time, potentially causing therapy to be interrupted or delayed
Nov 19, 2014Class IIZ-0204-2016Process control1. Device will perform the weekly automated tests hourly, which could cause the therapy capacitors to degrade sooner than intended and 2. While connected to AC or DC power and with no battery installed or the battery installed has a…
Nov 19, 2014Class IIZ-0262-2016Device DesignMRx Defib can be susceptible to one or both issues: 1. The C02 Inlet Port associated with end-tidal carbon dioxide (EtCO2) monitoring on MRx Monitor/Defibrillators can be pushed into the MRx housing, making it inaccessible. 2. The handle…
Nov 19, 2014Class IIZ-0963-2015Software designDevice may malfunction, which could cause therapy to be delayed, disabled, or delivered inadvertently.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K051134Heartstart MRX with Q-CPR Option, Models M3535A or M3536APhilips Medical Systems · 2005 · Direct predicate · ◆ in the 2005 ancestors bar of FIG. 12 Class I recalls
  • K031187Heartstart MRX, Model M3535APhilips Medical Systems · 2003 · Direct predicate · ◆ on the line of descent in FIG. 12 Class I recalls

What does this lineage say?

  • 2 of the 2 ancestors have a recall of any class; 2 have a Class I recall.
  • 3 other devices also cite its predicate K031187.

How does its category compare?

All MKJ devices

MKJ Automated External Defibrillators (Non-Wearable): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MKJ

48in 2025

2007: 72008: 132009: 82010: 42011: 112012: 102013: 72014: 112015: 62017: 42018: 202019: 252020: 522021: 412022: 192023: 242024: 272025: 482026 (partial year): 31
2007high 52 (2020) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MKJ

156in 2015

2007: 69 days median2008: 141 days median2009: 165 days median2010: 250 days median2011: 36 days median2012: 197 days median2013: 191 days median2014: 196 days median2015: 156 days median
2007high 250 (2010) · low 36 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MKJ

1in 2025

2007: 122008: 242009: 372010: 352011: 72012: 5, 1 Class I2013: 42014: 24, 15 Class I2015: 12016: 2, 1 Class I2017: 6, 4 Class I2018: 32019: 6, 2 Class I2020: 22021: 42022: 32023: 112024: 52025: 12026 (partial year): 3
2007high 37 (2009) · low 1 (2015)2026

Class I (23 since 2007) Class II/III not classified

Adverse event reports per year · MKJ

13,315in 2025

2007: 3,9582008: 4,7522009: 6,7822010: 7,3992011: 8,1702012: 9,7322013: 14,9552014: 15,3992015: 16,1292016: 17,0622017: 16,6842018: 16,5912019: 16,8612020: 16,1972021: 16,3002022: 14,8672023: 13,7662024: 15,1092025: 13,315
2007high 17,062 (2016) · low 3,958 (2007)2025

MAUDE reports naming product code MKJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007769123,958
200813141244,752
20098165376,782
20104250357,399
2011113678,170
2012101975 (1)9,732
20137191414,955
20141119624 (15)15,399
20156156116,129
20160—2 (1)17,062
20174—6 (4)16,684
201820—316,591
201925—6 (2)16,861
202052—216,197
202141—416,300
202219—314,867
202324—1113,766
202427—515,109
202548—113,315
202631—3—

What is it indicated for?

The HeartStart MRx is for use for the termination of ventricular tachycardia and ventricular fibrillation. The device is for use by qualified medical personnel trained in the operation of the device and qualified by training in basic life support, advanced cardiac support, or defibrillation. It must be used by or on the order of a physician. AED Therapy To be used in the presence of a suspected cardiac arrest on patients of at least 8 years of age that…

Read the full statement (300 words)

The HeartStart MRx is for use for the termination of ventricular tachycardia and ventricular fibrillation. The device is for use by qualified medical personnel trained in the operation of the device and qualified by training in basic life support, advanced cardiac support, or defibrillation. It must be used by or on the order of a physician.

AED Therapy

To be used in the presence of a suspected cardiac arrest on patients of at least 8 years of age that are unresponsive, not breathing and pulseless.

Manual Defibrillation

Asynchronous defibrillation is the initial treatment for ventricularfibrillation and ventricular tachycardia in patients that are pulseless and unresponsive. Synchronous dlefibrillation is indicated for termination of atrial fibrillation.

Non-invasive External Pacing Therapy

The pacing option is intended for treating patients with symptomatic bradycardia. Itcan also be helpful in patients with asystole, if performed early.

Pulse Oximetry

The SpO2 option is intended for use when it is beneficial to assess a patient's oxygen saturation level.

Non-invasive Blood Pressure Monitoring

The NBP option is intended for non-invasive measurement of a patient's arterial blood pressure.

End-tidal C02

The EtCO2 option is intended for non-invasive monitoring of a patient's exhaled carbon dioxide and to provide a respiration rate.

12-Lead ECG

The 12-Lead ECG function is to provide a conventional diagnostic 12-Lead ECG report, which may include measurements and interpretative statements.

Q-CPR

The Q-CPRTM option provides feedback designed to encourage rescuers to perform resuscitation in accordance with AHA/ERC guidelines for chest compression rate, depth, and duty cycle and ventilation rate, volume and flow rate (inflation time).

The Q-CPR option is contraindicated as folldws:

- The Q-CPR option is contraindicated for use on neonatal and pediatric patients (under 8 years of age or weighing less that 25 kg).

- The Q-CPR option is not for use when CPR is contraindicated.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K062233: Heartstart MRX Monitor/Defibrillator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K062233

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026