510(k) · Cleared
ClearedSteritite Perforated Bottom Rigid Reusable Sterilization Container System with SCF02 - Polypropylene Non-Woven Disposabl
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Case Medical, Inc. · FRG Wrap, Sterilization
Cleared on Jan 27, 2000 after a 304-day review. The FDA summary names its predicate without a number. 21 later devices descend from it.
- Decided
- Jan 27, 2000
- Review
- 304 days
- Class
- Class II
- Product code
- FRG
- Recalls
- None
- Predicates
- 0
21 later devices descend from it, 3 citing it directly.
- This deviceK991023 Steritite Perforated Bottom Rigid Reusable Sterilization Container…Case Medical, Inc. · 2000
- Descendant · cites it directly · 18 of its ownK012931 Genesis Sterrad Compatible Reusable Sterilization Container SystemAllegiance Healthcare Corp. · 2002
- Descendant · 2 generations on · 9 of its ownK023614 Steritite Rigid Reusable Sterilization Container SystemCase Medical, Inc. · 2003 · Recalled
- Descendant · 2 generations on · 7 of its ownK112535 Genesis Reusable Rigid Container SystemCarefusion 2200, Inc. · 2012
- Descendant · 3 generations on · 7 of its ownK050570 Miltex Rigid Sterilization Container SystemMiltex, Inc. · 2005
- Descendant · 4 generations on · 6 of its ownK091720 Sklarlite Rigid Sterilization Container SystemSklar Corp. · 2010
Showing 5 of 21 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 21 · See all- K012931Genesis Sterrad Compatible Reusable Sterilization Container SystemAllegiance Healthcare Corp. · 2002 · cites it directly18descendants
- K023614Steritite Rigid Reusable Sterilization Container SystemCase Medical, Inc. · 2003 · 2 generations on9descendants
- K112535Genesis Reusable Rigid Container SystemCarefusion 2200, Inc. · 2012 · 2 generations on7descendants
- K050570Miltex Rigid Sterilization Container SystemMiltex, Inc. · 2005 · 3 generations on7descendants
- K091720Sklarlite Rigid Sterilization Container SystemSklar Corp. · 2010 · 4 generations on6descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K991023 | Steritite Perforated Bottom Rigid Reusable Sterilization Container System with… | Case Medical, Inc. | 2000 | — |
| +1 | K012931 | Genesis Sterrad Compatible Reusable Sterilization Container System | Allegiance Healthcare Corp. | 2002 | — |
| +2 | K023614 | Steritite Rigid Reusable Sterilization Container System | Case Medical, Inc. | 2003 | 1 |
| +2 | K112535 | Genesis Reusable Rigid Container System | Carefusion 2200, Inc. | 2012 | — |
| +3 | K050570 | Miltex Rigid Sterilization Container System | Miltex, Inc. | 2005 | — |
| +4 | K091720 | Sklarlite Rigid Sterilization Container System | Sklar Corp. | 2010 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2002 | 1 | 0 |
| 2003 | 2 | 0 |
| 2005 | 1 | 0 |
| 2006 | 1 | 0 |
| 2010 | 2 | 0 |
| 2012 | 2 | 0 |
| 2013 | 1 | 0 |
| 2014 | 3 | 0 |
| 2015 | 2 | 0 |
| 2016 | 2 | 0 |
| 2017 | 1 | 0 |
| 2018 | 1 | 0 |
| 2019 | 1 | 0 |
| 2024 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FRG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FRG device
- #1 K234050 HALYARD® ONE-STEP® Sterilization Wrap…score 15.8 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Spunguard wrap/SteriTite® Container System Named without a submission number | |
| † | K960738 | Steritite Sealed Container (SC08F,SC06F,SC04F,SC08Q,SC06Q,SC04Q,SC08H,SC06H,SC04H) | 1997 |
What descends from it? (21)
See all 213 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K012931 (Allegiance Healthcare Corp., 2002) has gone furthest, with 18 descendants of its own.
How does its category compare?
All FRG devicesFRG Wrap, Sterilization: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FRG
9in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FRG
151in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FRG
2in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FRG
18in 2025
MAUDE reports naming product code FRG, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 182 | 0 | 1 |
| 2008 | 2 | — | 0 | 2 |
| 2009 | 4 | 171 | 0 | 2 |
| 2010 | 4 | 213 | 0 | 0 |
| 2011 | 6 | 110 | 0 | 12 |
| 2012 | 10 | 133 | 0 | 4 |
| 2013 | 6 | 146 | 2 | 5 |
| 2014 | 8 | 177 | 0 | 13 |
| 2015 | 12 | 196 | 0 | 9 |
| 2016 | 9 | 131 | 0 | 20 |
| 2017 | 9 | 260 | 29 | 7 |
| 2018 | 5 | 150 | 0 | 22 |
| 2019 | 9 | 258 | 0 | 10 |
| 2020 | 5 | 122 | 14 | 21 |
| 2021 | 4 | 170 | 0 | 9 |
| 2022 | 9 | 217 | 2 | 4 |
| 2023 | 9 | 230 | 0 | 13 |
| 2024 | 11 | 182 | 0 | 21 |
| 2025 | 9 | 151 | 0 | 18 |
| 2026 | 4 | 247 | 0 | — |
What is it indicated for?
The perforated base containers are part of the SteriTite® Reusable Rigid Sterilization Container system.
The SteriTite® perforated base containers using polypropylene nonwoven Disposable Filter # SCF02 may be used for the sterilization of surgical instruments in STERRAD 100 Sterilization for a hospital or other health care facilities.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K991023 · printed Nov 4, 2026
Cite this page
510(k) Report. “K991023: Steritite Perforated Bottom Rigid Reusable Sterilization Container System with SCF02 - Polypropylene Non-Woven Disposabl.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K991023
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026