510(k) Report

510(k) · Cleared

Cleared

Stockert Centrifugal Pump Console

K020571510(k) TraditionalCleared Sep 23, 2002214-day reviewClass II21 CFR 870.4220

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Stockert Instrumente GmbH · DTQ Console, Heart-Lung Machine, Cardiopulmonary Bypass

Cleared on Sep 23, 2002 as substantially equivalent to K991864 (Jostra Medizintechnik AG, 2000) and 2 other predicates after a 214-day review. Its family tree reaches back 2 generations to 1993.

Decided
Sep 23, 2002
Review
214 days
Class
Class II
Product code
DTQ
Recalls
None
Predicates
3

Its longest line of descent runs back 2 generations to K920077 (1993). 4 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2000: 1 other ancestor1998: 1 other ancestorK920077 · Nikkiso NK Pump · International Medical Products, Inc. · 1993K972740 · Himex Centriflow Centrifugal Perfusion Pump System (CFK01) · Himex Production Corp. · 199819901992199419961998200020022004
  1. Root · 2 generations backK920077 Nikkiso NK PumpInternational Medical Products, Inc. · 1993
  2. 1 generation backK972740 Himex Centriflow Centrifugal Perfusion Pump System (CFK01)Himex Production Corp. · 1998
  3. This deviceK020571 Stockert Centrifugal Pump ConsoleStockert Instrumente GmbH · 2002
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K920077Nikkiso NK PumpInternational Medical Products, Inc.1993—
−1K972740Himex Centriflow Centrifugal Perfusion Pump System (CFK01)Himex Production Corp.1998—
0 (this device)K020571Stockert Centrifugal Pump ConsoleStockert Instrumente GmbH2002—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199810
200010
FIG. 1 — Lineage of K020571, 1993–2002Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DTQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DTQ device

  1. #1 K221373 Essenz HLMscore 8.9 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K991864Rotaflow Centrifugal Pump SystemJostra Medizintechnik AG20002
*K972740Himex Centriflow Centrifugal Perfusion Pump System (CFK01)
Summary page 1
…edtronic Bio-Console 540/550 (Multiple) 0 RotaFlow Centrifugal Pump System (E99 1864) 0 Himex Centriflow Centrifugal Perfision Pump System (K972740) 0 Stockert Compact System (K982014) ~~ ~~ Stockert Instrumente GmbH 5 1O(k)…
Himex Production Corp.1998—
*K982014Stockert Compact System
Summary page 1
…0 RotaFlow Centrifugal Pump System (E99 1864) 0 Himex Centriflow Centrifugal Perfision Pump System (K972740) 0 Stockert Compact System (K982014) ~~ ~~ Stockert Instrumente GmbH 5 1O(k) July 9, 2002 Stockert Centrifugal…
Stoeckert Instrumente1998—
*—Medtronic Bio-Console 540/550
Named without a submission number
—

Also cleared against K991864: 8 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 3 companies; a new generation was cleared every 4.6 years on median.
  • 1 of the 4 ancestors has a recall of any class.
  • 8 other devices also cite its predicate K991864.

How does its category compare?

All DTQ devices

DTQ Console, Heart-Lung Machine, Cardiopulmonary Bypass: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DTQ

3in 2023

2007: 22008: 12009: 32010: 12011: 22014: 22015: 22017: 22018: 12019: 12021: 22023: 3
2007high 3 (2009) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DTQ

292in 2023

2009: 86 days median2023: 292 days median
2007high 292 (2023) · low 86 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DTQ

1in 2024

2007: 92008: 172009: 12010: 172011: 222012: 422013: 42014: 12018: 12019: 1, 1 Class I2022: 12023: 7, 1 Class I2024: 1
2007high 42 (2012) · low 0 (2015)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · DTQ

1,014in 2025

2007: 4202008: 5482009: 5892010: 8112011: 1,0812012: 1,6262013: 9062014: 1,2902015: 1,1842016: 7142017: 5272018: 6762019: 8572020: 6272021: 7292022: 7172023: 8182024: 8632025: 1,014
2007high 1,626 (2012) · low 420 (2007)2025

MAUDE reports naming product code DTQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—9420
20081—17548
20093861589
20101—17811
20112—221,081
20120—421,626
20130—4906
20142—11,290
20152—01,184
20160—0714
20172—0527
20181—1676
20191—1 (1)857
20200—0627
20212—0729
20220—1717
202332927 (1)818
20240—1863
20250—01,014
20260—0—

What is it indicated for?

The Stockert Centrifugal Pump Console (SCPC System) is a sofhvare-controlled cardiopulmonary bypass device containing an unintermptable power supply (UPS) and S3 Sensor Modules that is designed for operation of the Stockert Centrifugal Pump (SCP) and monitoring the cardiopulmonary bypass circuit. The SCPC System, in combination with the SCP and the COBE Revolution Pump Head, is indicated for speed-controlled pumping through the cardiopulmonary bypass…

Read the full statement (120 words)

The Stockert Centrifugal Pump Console (SCPC System) is a sofhvare-controlled cardiopulmonary bypass device containing an unintermptable power supply (UPS) and S3 Sensor Modules that is designed for operation of the Stockert Centrifugal Pump (SCP) and monitoring the cardiopulmonary bypass circuit. The SCPC System, in combination with the SCP and the COBE Revolution Pump Head, is indicated for speed-controlled pumping through the cardiopulmonary bypass circuit for typical durations of six hours or less.

The SCPC System has been qualified only for durations appropriate to cardiopulmonary bypass procedures and has not been qualified through in vitro, in vivo, or clinical studies, for long term use as a bridge to transplant, pending recovery of the natural head, or extracorporeal membrane oxygenation (ECMO) procedures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K020571: Stockert Centrifugal Pump Console.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K020571

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026