510(k) Report

510(k) · Cleared

Recalled · 2005

Baxter Accura System, Model 5M5660

K021615510(k) TraditionalCleared Nov 18, 2002186-day reviewClass II21 CFR 876.5860Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Baxter Healthcare Corp · KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System

Cleared on Nov 18, 2002 as substantially equivalent to K993064 (Gambro Renal Care Products, 1999) and 4 other predicates after a 186-day review. Its family tree reaches back 4 generations to 1991. 8 later devices descend from it. It has been recalled 3 times.

Decided
Nov 18, 2002
Review
186 days
Class
Class II
Product code
KDI
Recalls
3
Predicates
5

Its longest line of descent runs back 4 generations to K910215 (1991). 16 ancestors in all, the oldest K873279 (1987). 8 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1998: 3 other ancestors1997: 3 other ancestors1991: 2 other ancestors1996: 1 other ancestor1995: 1 other ancestor1993: 1 other ancestor1987: 1 other ancestor2007: 2 descendants cleared2004: 1 descendant cleared2005: 1 descendant cleared2008: 1 descendant cleared2022: 2 descendants cleared2009: 1 descendant clearedK910215 · Drake Willock System 1000 Dialysate Delivery Syst · Cd Medical, Inc. · 1991 · recalledK954987 · Altratouch 1000 Hemodialysis Delivery System · Althin Medical AB an Affiliate of Baxter Intl · 1996 · recalledK970446 · Drake Willock System & Altra Touch 1000 Dialysis Delivery System · Althin Medical AB an Affiliate of Baxter Intl · 1997 · recalledK993064 · Prisma CFM (Continuous Fluid Management System) · Gambro Renal Care Products · 1999 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 4 other ancestors2 generations back: 3 other ancestors3 generations back: 4 other ancestors4 generations back: 1 other ancestor 1 generation forward: 3 descendants2 generations forward: 4 descendants3 generations forward: 1 descendant K993064 · Prisma CFM (Continuous Fluid Management System) · Gambro Renal Care Products · 1999 · recalledK970446 · Drake Willock System & Altra Touch 1000 Dialysis Delivery System · Althin Medical AB an Affiliate of Baxter Intl · 1997 · recalledK954987 · Altratouch 1000 Hemodialysis Delivery System · Althin Medical AB an Affiliate of Baxter Intl · 1996 · recalledK910215 · Drake Willock System 1000 Dialysate Delivery Syst · Cd Medical, Inc. · 1991 · recalled0
  1. Root · 4 generations backK910215 Drake Willock System 1000 Dialysate Delivery SystCd Medical, Inc. · 1991 · Recalled
  2. 3 generations backK954987 Altratouch 1000 Hemodialysis Delivery SystemAlthin Medical AB an Affiliate of Baxter Intl · 1996 · Recalled
  3. 2 generations backK970446 Drake Willock System & Altra Touch 1000 Dialysis Delivery SystemAlthin Medical AB an Affiliate of Baxter Intl · 1997 · Recalled
  4. 1 generation backK993064 Prisma CFM (Continuous Fluid Management System)Gambro Renal Care Products · 1999 · Recalled
  5. This deviceK021615 Baxter Accura System, Model 5M5660Baxter Healthcare Corp · 2002
  6. Descendant · cites it directly · 4 of its ownK041005 Gambro Prismaflex and Gambro Prismaflex M60 & M100 SetsGambro Renal Products · 2004 · Recalled
  7. Descendant · 2 generations on · 1 of its ownK080519 Prismaflex M150 SetGambro Renal Products, Inc. · 2008 · Recalled
  8. Descendant · cites it directly · 1 of its ownK070320 Edwards Aquarius Hemofiltration System, Model Abm 01Edwards Lifesciences Services GmbH · 2007 · Recalled
  9. Descendant · 2 generations on · 1 of its ownK042938 Gambro Prismaflex HF1000 and HF1400 SetsGambro Renal Products · 2005 · Recalled
  10. Descendant · 3 generations on · 0 of its ownK220281 multiFiltratePRO SystemFresenius Medical Care Renal Therapies Group, LLC · 2022

Showing 5 of 8 descendants. See all descendants

Descendants cleared per year

2004: 12005: 12007: 22008: 12009: 12022: 2
2004high 2 (2007) · low 0 (2006)2026

Most influential descendants

Showing 5 of 8 · See all
  • K041005Gambro Prismaflex and Gambro Prismaflex M60 & M100 SetsGambro Renal Products · 2004 · cites it directly4descendants
  • K080519Prismaflex M150 SetGambro Renal Products, Inc. · 2008 · 2 generations on1descendant
  • K070320Edwards Aquarius Hemofiltration System, Model Abm 01Edwards Lifesciences Services GmbH · 2007 · cites it directly1descendant
  • K042938Gambro Prismaflex HF1000 and HF1400 SetsGambro Renal Products · 2005 · 2 generations on1descendant
  • K220281multiFiltratePRO SystemFresenius Medical Care Renal Therapies Group, LLC · 2022 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K910215Drake Willock System 1000 Dialysate Delivery SystCd Medical, Inc.19915
−3K954987Altratouch 1000 Hemodialysis Delivery SystemAlthin Medical AB an Affiliate of Baxter Intl19961
−2K970446Drake Willock System & Altra Touch 1000 Dialysis Delivery SystemAlthin Medical AB an Affiliate of Baxter Intl19975
−1K993064Prisma CFM (Continuous Fluid Management System)Gambro Renal Care Products19991
0 (this device)K021615Baxter Accura System, Model 5M5660Baxter Healthcare Corp2002—
+1K041005Gambro Prismaflex and Gambro Prismaflex M60 & M100 SetsGambro Renal Products20047
+2K080519Prismaflex M150 SetGambro Renal Products, Inc.20083
+1K070320Edwards Aquarius Hemofiltration System, Model Abm 01Edwards Lifesciences Services GmbH20071
+2K042938Gambro Prismaflex HF1000 and HF1400 SetsGambro Renal Products20057
+3K220281multiFiltratePRO SystemFresenius Medical Care Renal Therapies Group, LLC2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
199120
199310
199510
199610
199730
199830

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200410
200510
200720
200810
200910
202220
FIG. 1 — Lineage of K021615, 1991–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KDI device

  1. #1 K243874 FX CorAL 60 (F00012969); FX CorAL 80…score 18.2 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (5)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K993064Prisma CFM (Continuous Fluid Management System)
Summary page 1
…stem for Continuous Renal Replacement Therapy Classification Name: High Permeability Hemodialysis System per 21 CFR 876.5860 Equivalent Predicate: PFUSMATMSystem (K993064, K98168 1,K946279) Diapact CRRT (K973322) Bml 1 Blood Monitor Pump Disposable Tub…
Gambro Renal Care Products19991
*K981681Prisma CFM (Continuous Fluid Management System)
Summary page 1
…Continuous Renal Replacement Therapy Classification Name: High Permeability Hemodialysis System per 21 CFR 876.5860 Equivalent Predicate: PFUSMATMSystem (K993064, K98168 1,K946279) Diapact CRRT (K973322) Bml 1 Blood Monitor Pump Disposable Tubing Set…
Gambro Healthcare19981
*K946279Prisma CFM (Continuous Fluid Management System)
Summary page 1
…s Renal Replacement Therapy Classification Name: High Permeability Hemodialysis System per 21 CFR 876.5860 Equivalent Predicate: PFUSMATMSystem (K993064, K98168 1,K946279) Diapact CRRT (K973322) Bml 1 Blood Monitor Pump Disposable Tubing Set…
Cobe Renal Care, Inc.1997—
*K973322Diapact CRRT
Summary page 1
…e: High Permeability Hemodialysis System per 21 CFR 876.5860 Equivalent Predicate: PFUSMATMSystem (K993064, K98168 1,K946279) Diapact CRRT (K973322) Bml 1 Blood Monitor Pump Disposable Tubing Set (K9 113 15/A) Device Description…
B.Braun Medical, Inc.1998—
*K911315Extracorporeal Blood Pumping Syst for Hemofiltrat
Summary page 1
…K993064, K98168 1,K946279) Diapact CRRT (K973322) Bml 1 Blood Monitor Pump Disposable Tubing Set (K9 113 15/A) Device Description: The Accura System hardware consists of blood pumps, scales and various monito…
Baxter Healthcare Corp19911

Also cleared against K993064: 1 other device →

What descends from it? (8)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K041005Gambro Prismaflex and Gambro Prismaflex M60 & M100 SetsGambro Renal Products20044
K070320Edwards Aquarius Hemofiltration System, Model Abm 01Edwards Lifesciences Services GmbH20071
K063293Edwards Aqualine Sterile Tubing Set; Edwards Aqualins Sterile Tubing Set; Edwards…Edwards Lifesciences Services GmbH20070

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 29, 2005Not classifiedZ-0153-06OtherA software anomaly that occurs when the Reset Totals option is selected during CVVHD therapy with a diaylsate flow rate of less than 600 mL/hour, or CVVH therapy with a predilution flow rate of less than 600 mL/hour, causes balance alarms…
Jul 13, 2005Not classifiedZ-1380-05Device DesignIn the event therapy is terminated, as part of routine instrument programming or therapy maintenance, the Accura instrument may experience difficulty in performing a successful self-test (failure) upon an immediate attempt to restart…
Jul 26, 2004Not classifiedZ-1338-04OtherThe Accura machine display screen may go blank during patient treatment. There is a potential risk to the patient in that the operator may try to manipulate the controls in response to a blank screen, which could affect the current…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 4 companies; a new generation was cleared every 3.1 years on median.
  • 6 of the 16 ancestors have a recall of any class.
  • Of its descendants, K041005 (Gambro Renal Products, 2004) has gone furthest, with 4 descendants of its own.
  • 1 other device also cites its predicate K993064.

How does its category compare?

All KDI devices

KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KDI

9in 2025

2007: 112008: 62009: 42010: 92011: 52012: 62013: 112014: 82015: 52016: 52017: 82018: 22019: 42020: 92021: 22022: 72023: 72024: 72025: 92026 (partial year): 6
2007high 11 (2007) · low 2 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KDI

199in 2025

2007: 91 days median2008: 148 days median2009: 236 days median2010: 186 days median2011: 85 days median2012: 153 days median2013: 247 days median2014: 164 days median2015: 69 days median2016: 230 days median2017: 188 days median2019: 263 days median2020: 266 days median2022: 259 days median2023: 157 days median2024: 235 days median2025: 199 days median2026 (partial year): 154 days median
2007high 266 (2020) · low 69 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KDI

2in 2025

2007: 42009: 32010: 12011: 42012: 12013: 22014: 32015: 52016: 42017: 12018: 12019: 62021: 22022: 172023: 8, 8 Class I2024: 4, 2 Class I2025: 22026 (partial year): 2
2007high 17 (2022) · low 0 (2008)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · KDI

2,786in 2025

2007: 9162008: 1,0422009: 5222010: 8232011: 2,2702012: 1,7652013: 2,3602014: 6,1542015: 4,1822016: 7662017: 9632018: 1,7162019: 1,5872020: 1,6332021: 1,9442022: 2,1802023: 2,6922024: 2,4412025: 2,786
2007high 6,154 (2014) · low 522 (2009)2025

MAUDE reports naming product code KDI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711914916
2008614801,042
200942363522
201091861823
201158542,270
2012615311,765
20131124722,360
2014816436,154
201556954,182
201652304766
201781881963
20182—11,716
2019426361,587
2020926601,633
20212—21,944
20227259172,180
202371578 (8)2,692
202472354 (2)2,441
2025919922,786
202661542—

What is it indicated for?

The Baxter Accura System is indicated for continuous solute and/or fluid removal in patients with acute renal failure or fluid overload. The Baxter Accura System may also be used in Therapeutic Plasma Exchange (TPE) therapies.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K021615: Baxter Accura System, Model 5M5660.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K021615

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026