510(k) Report

510(k) · Cleared

Cleared

Welch Allyn 1500 Patient Monitor

K101619510(k) TraditionalCleared Nov 12, 2010156-day reviewClass II21 CFR 870.1025

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Schiller AG · MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms)

Cleared on Nov 12, 2010 as substantially equivalent to K053207 (Schiller AG, 2006) and 4 other predicates after a 156-day review. Its family tree reaches back 10 generations to 1997. 1 of the 82 devices in its family, counting itself, has a Class I recall. 4 later devices descend from it.

Decided
Nov 12, 2010
Review
156 days
Class
Class II
Product code
MHX
Recalls
None
Predicates
5

Its longest line of descent runs back 10 generations to K962603 (1997). 77 ancestors in all, the oldest K842616 (1984). 4 later devices descend from it, 1 citing it directly. 1 of the 82 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2007: 1 other ancestor2006: 2 other ancestors2005: 2 other ancestors2002: 4 other ancestors2004: 3 other ancestors2000: 4 other ancestors1998: 7 other ancestors1997: 7 other ancestors, 1 with a Class I recall11996: 6 other ancestors1999: 4 other ancestors1995: 7 other ancestors1993: 3 other ancestors1990: 4 other ancestors1984: 1 other ancestor2003: 1 other ancestor2001: 1 other ancestor1994: 4 other ancestors1991: 4 other ancestors1989: 1 other ancestor1992: 1 other ancestor2014: 1 descendant cleared2017: 1 descendant cleared2018: 1 descendant cleared2020: 1 descendant clearedK962603 · Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables · Masimo Corp. · 1997K973887 · Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables · Masimo Corp. · 1998K982255 · Model 2000 Pulse Oximeter · Ivy Biomedical Systems, Inc. · 1998K991823 · N-395 Pulse Oximeter, Model N-395 · Nellcor Puritan Bennett, Inc. · 1999×2: 2 generations cleared close together, K012891 (2002), K021090 (2002) K033048 · Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS, 740-2NL, 740M-2NL, 740-2NN, 740M-2NN, 740-3MS, 740M-3MS · Cas Medical Systems, Inc. · 2004 · recalledK050844 · 750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL, 750CM-2NL, 750C-3MS, 750CM-3MS, 750C-3NL, 750CM-3NL · Cas Medical Systems, Inc. · 2005K060065 · CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter Bedside Monitor · Oridion Capnography, Inc. · 2006 · recalledK072295 · Capnostream 20 with A2 Adaptive Averaging Software · Oridion Capnography, Inc. · 200719801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 4 other ancestors2 generations back: 7 other ancestors3 generations back: 20 other ancestors4 generations back: 19 other ancestors5 generations back: 10 other ancestors, 1 with a Class I recall16 generations back: 5 other ancestors7 generations back: 2 other ancestors 1 generation forward: 1 descendant2 generations forward: 1 descendant3 generations forward: 1 descendant4 generations forward: 1 descendant K072295 · Capnostream 20 with A2 Adaptive Averaging Software · Oridion Capnography, Inc. · 2007K060065 · CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter Bedside Monitor · Oridion Capnography, Inc. · 2006 · recalledK050844 · 750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL, 750CM-2NL, 750C-3MS, 750CM-3MS, 750C-3NL, 750CM-3NL · Cas Medical Systems, Inc. · 2005K033048 · Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS, 740-2NL, 740M-2NL, 740-2NN, 740M-2NN, 740-3MS, 740M-3MS · Cas Medical Systems, Inc. · 2004 · recalledK021090 · Oximax N-550 Pulse Oximeter,Model N-550 Pulse Oximeter · Nellcor Puritan Bennett, Inc. · 2002K012891 · Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax Sensors and Cables (Aka Accessories) · Nellcor Puritan Bennett, Inc. · 2002 · recalledK991823 · N-395 Pulse Oximeter, Model N-395 · Nellcor Puritan Bennett, Inc. · 1999K982255 · Model 2000 Pulse Oximeter · Ivy Biomedical Systems, Inc. · 1998K973887 · Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables · Masimo Corp. · 1998K962603 · Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables · Masimo Corp. · 1997−10−50
  1. Root · 10 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 6 generations between
  3. 3 generations backK050844 750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL…Cas Medical Systems, Inc. · 2005
  4. 2 generations backK060065 CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One…Oridion Capnography, Inc. · 2006 · Recalled
  5. 1 generation backK072295 Capnostream 20 with A2 Adaptive Averaging SoftwareOridion Capnography, Inc. · 2007
  6. This deviceK101619 Welch Allyn 1500 Patient MonitorSchiller AG · 2010
  7. Descendant · cites it directly · 3 of its ownK133973 Tempus Pro with Enhanced FeaturesRemote Diagnostic Technologies, Ltd. · 2014
  8. Descendant · 2 generations on · 2 of its ownK170567 Tempus Pro Patient MonitorRemote Diagnostic Technologies, Ltd. · 2017
  9. Descendant · 3 generations on · 1 of its ownK173768 Tempus Pro Patient MonitorRemote Diagnostic Technologies, Ltd. · 2018
  10. Descendant · 4 generations on · 0 of its ownK201746 Tempus Pro Patient MonitorRemote Diagnostic Technologies Limited · 2020 · Recalled
Show all 10 generations
  1. Root · 10 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 9 generations backK973887 Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and…Masimo Corp. · 1998
  3. 8 generations backK982255 Model 2000 Pulse OximeterIvy Biomedical Systems, Inc. · 1998
  4. 7 generations backK991823 N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc. · 1999
  5. 6 generations backK012891 Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax…Nellcor Puritan Bennett, Inc. · 2002 · Recalled
  6. 5 generations backK021090 Oximax N-550 Pulse Oximeter,Model N-550 Pulse OximeterNellcor Puritan Bennett, Inc. · 2002
  7. 4 generations backK033048 Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS…Cas Medical Systems, Inc. · 2004 · Recalled
  8. 3 generations backK050844 750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL…Cas Medical Systems, Inc. · 2005
  9. 2 generations backK060065 CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One…Oridion Capnography, Inc. · 2006 · Recalled
  10. 1 generation backK072295 Capnostream 20 with A2 Adaptive Averaging SoftwareOridion Capnography, Inc. · 2007
  11. This deviceK101619 Welch Allyn 1500 Patient MonitorSchiller AG · 2010

Class I recalls in this family

Most influential descendants

Showing 4 of 4 · See all
  • K133973Tempus Pro with Enhanced FeaturesRemote Diagnostic Technologies, Ltd. · 2014 · cites it directly3descendants
  • K170567Tempus Pro Patient MonitorRemote Diagnostic Technologies, Ltd. · 2017 · 2 generations on2descendants
  • K173768Tempus Pro Patient MonitorRemote Diagnostic Technologies, Ltd. · 2018 · 3 generations on1descendant
  • K201746Tempus Pro Patient MonitorRemote Diagnostic Technologies Limited · 2020 · 4 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K962603Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp.1997—
−9K973887Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and CablesMasimo Corp.1998—
−8K982255Model 2000 Pulse OximeterIvy Biomedical Systems, Inc.1998—
−7K991823N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc.1999—
−6K012891Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax Sensors and…Nellcor Puritan Bennett, Inc.20021
−5K021090Oximax N-550 Pulse Oximeter,Model N-550 Pulse OximeterNellcor Puritan Bennett, Inc.2002—
−4K033048Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS, 740-2NL…Cas Medical Systems, Inc.20041
−3K050844750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL, 750CM-2NL…Cas Medical Systems, Inc.2005—
−2K060065CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter…Oridion Capnography, Inc.20063
−1K072295Capnostream 20 with A2 Adaptive Averaging SoftwareOridion Capnography, Inc.2007—
0 (this device)K101619Welch Allyn 1500 Patient MonitorSchiller AG2010—
+1K133973Tempus Pro with Enhanced FeaturesRemote Diagnostic Technologies, Ltd.2014—
+2K170567Tempus Pro Patient MonitorRemote Diagnostic Technologies, Ltd.2017—
+3K173768Tempus Pro Patient MonitorRemote Diagnostic Technologies, Ltd.2018—
+4K201746Tempus Pro Patient MonitorRemote Diagnostic Technologies Limited20207

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198410
198910
199040
199140
199210
199330
199440
199570
199660
199771
199870
199940
200040
200110
200240
200310
200430
200520
200620
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
201710
201810
202010
FIG. 1 — Lineage of K101619, 1997–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MHX device

  1. #1 K251702 IntelliVue Patient Monitor MX750; IntelliVue…score 23.0 · 40 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (5)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K053207Argus, Model LCM
Summary page 1
…- 12-lead Rest-ECG Analysis The 12-lead Rest-ECG Analysis algorithm used in the 1500 Patient Monitor has been FDA- cleared in the SCHILLER ARGUS [CM K053207). Parameters - Temperature The Patient Temperature parameter circuitry and algorithm used in theWelch Allyn 1…
Schiller AG2006—
*K063814BP-200 Plus
Summary page 1
…e The Not Invasive Blood Pressure parameter circuitry and algorithm used in the 1500 Patient Monitor has been FDA-cleared in the SCHILLER BP-200plus (K063814). Parameters -Invasive Blood Pressure The Invasive Blood Pressure parameter circuitry and algorithm used in t…
Schiller AG2007—
*K051352Oximax NPB-40 Handheld Pulse Oximeter
Summary page 2
…pOZ) The SpO2 parameter circuitry and algorithm used in the 1500 Patient Monitor has been FDA- cleared in the Nellcor Oximax NPB-40 Pulse Oximeter (K051352). Parameters - ECG Arrhythmia / ST-segment Analysis The Mortara ECG Arrhythmia and ST-segment analysis algo…
Nellcor Puritan Bennett, Inc.2005—
*K020550Passport 2 with View 12 Ecg Analysis Module Model # 0998-00-0170-XXXX
Summary page 5
…e medical device standards and equivalent to the SCHILLER ARGUS LCMKOS32O7; SP02 Module Nelcor K051352; C02 Module Oridien K072295; ECG Library Mortara K020550; NIBPNodule SCHILLER K063814 all parameters currently on the market. Baar (Switzerland) 2 8 th May 2010…
Datascope Corp.20021
*K072295Capnostream 20 with A2 Adaptive Averaging Software
Summary page 5
…e, comply with the appropriate medical device standards and equivalent to the SCHILLER ARGUS LCMKOS32O7; SP02 Module Nelcor K051352; C02 Module Oridien K072295; ECG Library Mortara K020550; NIBPNodule SCHILLER K063814 all parameters currently on the market. Baar (Switzerland)…
Oridion Capnography, Inc.2007—

What descends from it? (4)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K133973Tempus Pro with Enhanced FeaturesRemote Diagnostic Technologies, Ltd.20143

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K970209Capnocheck PlusBci Intl., Inc. · 1997 · 5 generations back · ◆ in the 1997 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 13 years and passes through 6 companies; a new generation was cleared every 1.1 years on median.
  • 13 of the 77 ancestors have a recall of any class; 1 has a Class I recall.
  • Of its descendants, K133973 (Remote Diagnostic Technologies, Ltd., 2014) has gone furthest, with 3 descendants of its own.

How does its category compare?

All MHX devices

MHX Monitor, Physiological, Patient (With Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · MHX

8in 2025

2007: 152008: 162009: 132010: 202011: 122012: 162013: 212014: 132015: 142016: 132017: 142018: 112019: 72020: 112021: 52022: 152023: 82024: 52025: 82026 (partial year): 14
2007high 21 (2013) · low 5 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MHX

192in 2025

2007: 96 days median2008: 58 days median2009: 57 days median2010: 90 days median2011: 81 days median2012: 88 days median2013: 120 days median2014: 248 days median2015: 203 days median2016: 149 days median2017: 134 days median2018: 203 days median2019: 243 days median2020: 196 days median2021: 195 days median2022: 189 days median2023: 229 days median2024: 181 days median2025: 192 days median2026 (partial year): 205 days median
2007high 248 (2014) · low 57 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MHX

21so far in 2026, the most since 2007

2007: 32008: 22009: 72010: 132011: 162012: 112013: 142014: 62015: 52016: 72017: 62018: 122019: 62022: 62023: 32024: 32025: 152026 (partial year): 21
2007high 21 (2026) · low 0 (2020)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MHX

3,761in 2025

2007: 1312008: 2322009: 3822010: 9552011: 9492012: 6762013: 1,9972014: 1,6092015: 1,2842016: 1,1052017: 1,1152018: 2,1572019: 1,4622020: 1,7142021: 2,4232022: 1,4702023: 2,2542024: 2,8142025: 3,761
2007high 3,761 (2025) · low 131 (2007)2025

MAUDE reports naming product code MHX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200715963131
200816582232
200913577382
2010209013955
2011128116949
2012168811676
201321120141,997
20141324861,609
20151420351,284
20161314971,105
20171413461,115
201811203122,157
2019724361,462
20201119601,714
2021519502,423
20221518961,470
2023822932,254
2024518132,814
20258192153,761
20261420521—

What is it indicated for?

The Welch Allyn 1500 Patient Monitor is an ultra-flat patient monitor designed for neonates; children, adult and paediatric use. It has a LCD screen for comprehensive vital data monitoring. Mains power supply is used for stationary use. The Welch Allyn 1500 Patient Monitor also provides full vital data monitoring during transport with the built-in battery. The Welch Allyn® 1500 Patient Monitor patient monitoring unit is designed for the monitoring of…

Read the full statement (234 words)

The Welch Allyn 1500 Patient Monitor is an ultra-flat patient monitor designed for

neonates; children, adult and paediatric use. It has a LCD screen for comprehensive

vital data monitoring.

Mains power supply is used for stationary use. The Welch Allyn 1500 Patient Monitor

also provides full vital data monitoring during transport with the built-in battery.

The Welch Allyn® 1500 Patient Monitor patient monitoring unit is designed for the

monitoring of vital parameters such as ECG, SpO2, etCO2, non invasive blood pressure

(NIBP), invasive blood pressure (11BP), temperature and respiration of a patient.

>The device is intended to be used by qualified doctors or trained medical

personnel.

>The device is not suitable for transport.

>There is no danger for patients with pacemaker.

>The device is intended for the monitoring of one patient at a time.

> The device is not designed for sterile use nor is it designed for outdoor use.

- Do not use this monitor in areas where there is any danger of explosion or in the

presence of flammable gases.

> The device is classified CF. It is defibrillation protected when the original

accessories are used. However, as a safety precaution when possible, remove the

electrodes before defibrillation.

> This product is not designed for direct cardiac application.

> The arrhythmia module is not intended for use with neonatal patients.

> The ST-analysis module is not intended for use with neonatal patients.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K101619: Welch Allyn 1500 Patient Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K101619

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026