510(k) · Cleared
ClearedSyngo Neuro PBV CT
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Siemens AG · JAK System, X-Ray, Tomography, Computed
Cleared on Nov 30, 2006 as substantially equivalent to K053024 (Siemens AG, 2005) and 2 other predicates after a 10-day review. Its family tree reaches back 6 generations to 1995.
- Decided
- Nov 30, 2006
- Review
- 10 days
- Class
- Class II
- Product code
- JAK
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 6 generations to K954355 (1995). 17 ancestors in all, the oldest K880965 (1988). No later device cites it as a predicate yet.
- Root · 6 generations backK954355 Advantage Windows 3D with Navigator OptionGeneral Electric Co. · 1995
- 5 generations backK974715 Advantage 3D XRGE Medical Systems · 1998
- 4 generations backK984634 3D-AngioSiemens Medical Corp. · 1999
- 3 generations backK011447 IN Space 3DSiemens Medical Solutions USA, Inc. · 2001
- 2 generations backK043469 Syngo Inspace 4DSiemens AG Medical Solutions · 2005
- 1 generation backK053024 Syngo Neuro Dsa CTSiemens AG · 2005
- This deviceK063507 Syngo Neuro PBV CTSiemens AG · 2006
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −6 | K954355 | Advantage Windows 3D with Navigator Option | General Electric Co. | 1995 | — |
| −5 | K974715 | Advantage 3D XR | GE Medical Systems | 1998 | — |
| −4 | K984634 | 3D-Angio | Siemens Medical Corp. | 1999 | — |
| −3 | K011447 | IN Space 3D | Siemens Medical Solutions USA, Inc. | 2001 | — |
| −2 | K043469 | Syngo Inspace 4D | Siemens AG Medical Solutions | 2005 | — |
| −1 | K053024 | Syngo Neuro Dsa CT | Siemens AG | 2005 | — |
| 0 (this device) | K063507 | Syngo Neuro PBV CT | Siemens AG | 2006 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1988 | 2 | 0 |
| 1991 | 1 | 0 |
| 1998 | 3 | 0 |
| 2000 | 1 | 0 |
| 2001 | 2 | 0 |
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JAK device
- #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K053024 | Syngo Neuro Dsa CTSummary page 2…device: Manufacturer Product 510(k) Clearance date 1. Siemens NeuroDSA CT K053024 11/04/2005 /*16ko 2. Siemens Perfusion CT K033832 12/23/2003 3. Siemen… | 2005 |
| * | K033832 | Syngo Perfusion-CTSummary page 2…e date 1. Siemens NeuroDSA CT K053024 11/04/2005 /*16ko 2. Siemens Perfusion CT K033832 12/23/2003 3. Siemens AG Leonardo (syngo Fused Vision 3D) K040970 07/08/2004 8. Device Descri… | 2003 |
| * | K040970 | LeonardoSummary page 2…4/2005 /*16ko 2. Siemens Perfusion CT K033832 12/23/2003 3. Siemens AG Leonardo (syngo Fused Vision 3D) K040970 07/08/2004 8. Device Description and Intended Use: syngo Neuro PBV CT is a dedicated post-processing applicati… | 2004 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 11 years and passes through 6 companies; a new generation was cleared every 2.4 years on median.
- 3 of the 17 ancestors have a recall of any class.
- 1 other device also cites its predicate K053024.
How does its category compare?
All JAK devicesJAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JAK
27in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JAK
141in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JAK
17in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JAK
219in 2025
MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 14 | 27 | 11 | 76 |
| 2008 | 26 | 42 | 16 | 120 |
| 2009 | 15 | 31 | 29 | 105 |
| 2010 | 7 | 92 | 51 | 119 |
| 2011 | 16 | 155 | 34 | 205 |
| 2012 | 28 | 121 | 23 | 192 |
| 2013 | 17 | 132 | 11 | 414 |
| 2014 | 30 | 200 | 10 | 308 |
| 2015 | 30 | 140 | 28 | 454 |
| 2016 | 25 | 129 | 44 | 365 |
| 2017 | 29 | 96 | 33 | 338 |
| 2018 | 24 | 114 | 10 | 543 |
| 2019 | 28 | 94 | 5 | 233 |
| 2020 | 30 | 112 | 8 | 177 |
| 2021 | 20 | 145 | 15 | 261 |
| 2022 | 30 | 131 | 9 | 199 |
| 2023 | 27 | 139 | 9 | 310 |
| 2024 | 26 | 141 | 20 | 212 |
| 2025 | 27 | 141 | 17 | 219 |
| 2026 | 21 | 167 | 23 | — |
What is it indicated for?
syngo Neuro PBV CT is a dedicated post-processing application used in cases of suspected stroke. The application calculates a volume that represents the amount of blood in the parenchyma. Decreased blood volume in a certain region of the brain is an indicator for stroke. As syngo Neuro PBV CT calculates a blood volume the stroke region can be measured in 3D. Neuro PBV CT is calculated using a non-enhanced CT dataset (NECT) and a CT Angiography (CTA) that…
Read the full statement (161 words)
syngo Neuro PBV CT is a dedicated post-processing application used in cases of suspected stroke. The application calculates a volume that represents the amount of blood in the parenchyma. Decreased blood volume in a certain region of the brain is an indicator for stroke. As syngo Neuro PBV CT calculates a blood volume the stroke region can be measured in 3D.
Neuro PBV CT is calculated using a non-enhanced CT dataset (NECT) and a CT Angiography (CTA) that both are acquired during modern stroke protocol. The two volumes are first registered and after segmentation of bones, CSF, and vessels the volumes are low pass filtered and subtracted. The result is adjusted to the enhancement of a vessel to allow semi-quantitative measurements.
Syngo Neuro PBV CT helps to diagnosing stroke while enlarging the cerebral blood volume (CBV) of perfusion CT (PCT) that covers only a portion of the brain. Thus it facilitates the treatment decision and is an addition to Perfusion CT.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K063507 · printed Nov 6, 2026
Cite this page
510(k) Report. “K063507: Syngo Neuro PBV CT.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K063507
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026