510(k) Report

510(k) · Cleared

Recalled · 2009

Eclos Computed Tomography X-Ray System

K071806510(k) AbbreviatedCleared Aug 28, 200757-day reviewClass II21 CFR 892.1750Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Hitachi Medical Systems America, Inc. · JAK System, X-Ray, Tomography, Computed

Cleared on Aug 28, 2007 as substantially equivalent to K040902 (Hitachi Medical Systems America, Inc., 2004) after a 57-day review. Its family tree reaches back 6 generations to 1995. 12 later devices descend from it. It has been recalled once.

Decided
Aug 28, 2007
Review
57 days
Class
Class II
Product code
JAK
Recalls
1
Predicates
1

Its longest line of descent runs back 6 generations to K944131 (1995). 9 ancestors in all, the oldest K920950 (1992). 12 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1995: 1 other ancestor1992: 1 other ancestor1994: 1 other ancestor2011: 1 descendant cleared2009: 1 descendant cleared2012: 1 descendant cleared2017: 1 descendant cleared2013: 1 descendant cleared2014: 1 descendant cleared2016: 1 descendant cleared2022: 1 descendant cleared2026: 2 descendants cleared2018: 1 descendant cleared2025: 1 descendant clearedK944131 · Anatom 2000 · Analogic Corp. · 1995K964890 · Anatom 2000 · Analogic Corp. · 1997K982631 · Philips Tomoscan CS · Philips Medical Systems, Inc. · 1998K991278 · Philips Tomoscan AV-NT · Philips Medical Systems North America, Inc. · 1999K014240 · Pronto · Hitachi Medical Systems America, Inc. · 2002K040902 · Hitachi Presto · Hitachi Medical Systems America, Inc. · 2004 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 4 generations back: 2 other ancestors5 generations back: 1 other ancestor 1 generation forward: 2 descendants2 generations forward: 4 descendants3 generations forward: 3 descendants4 generations forward: 2 descendants5 generations forward: 1 descendant K040902 · Hitachi Presto · Hitachi Medical Systems America, Inc. · 2004 · recalledK014240 · Pronto · Hitachi Medical Systems America, Inc. · 2002K991278 · Philips Tomoscan AV-NT · Philips Medical Systems North America, Inc. · 1999K982631 · Philips Tomoscan CS · Philips Medical Systems, Inc. · 1998K964890 · Anatom 2000 · Analogic Corp. · 1997K944131 · Anatom 2000 · Analogic Corp. · 1995−50+5
  1. Root · 6 generations backK944131 Anatom 2000Analogic Corp. · 1995
  2. 5 generations backK964890 Anatom 2000Analogic Corp. · 1997
  3. 4 generations backK982631 Philips Tomoscan CSPhilips Medical Systems, Inc. · 1998
  4. 3 generations backK991278 Philips Tomoscan AV-NTPhilips Medical Systems North America, Inc. · 1999
  5. 2 generations backK014240 ProntoHitachi Medical Systems America, Inc. · 2002
  6. 1 generation backK040902 Hitachi PrestoHitachi Medical Systems America, Inc. · 2004 · Recalled
  7. This deviceK071806 Eclos Computed Tomography X-Ray SystemHitachi Medical Systems America, Inc. · 2007
  8. Descendant · cites it directly · 9 of its ownK102677 Bodytom NL 4000Neurologica Corporation · 2011
  9. Descendant · 2 generations on · 4 of its ownK170238 BodyTom EliteNeurologica Corporation, A Subsidiary of Samsung Electronics · 2017
  10. Descendant · 3 generations on · 2 of its ownK213649 BodyTom 64Neurologica Corporation · 2022
  11. Descendant · 2 generations on · 2 of its ownK131431 Airo CT SystemMobius Imaging, LLC · 2013 · Recalled
  12. Descendant · 4 generations on · 1 of its ownK242811 BodyTom 64Neurologica Corporation, A Subsidiary of Samsung · 2025

Showing 5 of 12 descendants. See all descendants

Descendants cleared per year

2009: 12011: 12012: 12013: 12014: 12016: 12017: 12018: 12022: 12025: 12026: 2
2009high 2 (2026) · low 0 (2010)2026

Most influential descendants

Showing 5 of 12 · See all
  • K102677Bodytom NL 4000Neurologica Corporation · 2011 · cites it directly9descendants
  • K170238BodyTom EliteNeurologica Corporation, A Subsidiary of Samsung Electronics · 2017 · 2 generations on4descendants
  • K213649BodyTom 64Neurologica Corporation · 2022 · 3 generations on2descendants
  • K131431Airo CT SystemMobius Imaging, LLC · 2013 · 2 generations on2descendants
  • K242811BodyTom 64Neurologica Corporation, A Subsidiary of Samsung · 2025 · 4 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K944131Anatom 2000Analogic Corp.1995—
−5K964890Anatom 2000Analogic Corp.1997—
−4K982631Philips Tomoscan CSPhilips Medical Systems, Inc.1998—
−3K991278Philips Tomoscan AV-NTPhilips Medical Systems North America, Inc.1999—
−2K014240ProntoHitachi Medical Systems America, Inc.2002—
−1K040902Hitachi PrestoHitachi Medical Systems America, Inc.20044
0 (this device)K071806Eclos Computed Tomography X-Ray SystemHitachi Medical Systems America, Inc.2007—
+1K102677Bodytom NL 4000Neurologica Corporation2011—
+2K170238BodyTom EliteNeurologica Corporation, A Subsidiary of Samsung Electronics2017—
+3K213649BodyTom 64Neurologica Corporation2022—
+2K131431Airo CT SystemMobius Imaging, LLC20131
+4K242811BodyTom 64Neurologica Corporation, A Subsidiary of Samsung2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199210
199410
199510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201110
201210
201310
201410
201610
201710
201810
202210
202510
202620
FIG. 1 — Lineage of K071806, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JAK device

  1. #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K040902Hitachi Presto
Summary page 1
…ATION NUMBER: Sec. 892.1750 TRADE/PROPRIETARY NAME: ECLOS PREDICATE DEVICE(S): Hitachi PRESTO CT, 510(k) K040902 Device Intended Use The ECLOS Computed Tomography system is an x-ray imaging device that produces cross-sectional image of the…
Hitachi Medical Systems America, Inc.20044

Also cleared against K040902: 3 other devices →

What descends from it? (12)

See all 12

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K102677Bodytom NL 4000Neurologica Corporation20119
K091103Guideshot Option for CXR4 and Eclos CT SystemsHitachi Medical Systems America, Inc.20091

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 14, 2009Not classifiedZ-1652-2009Software designIncorrect scale on image: A software error can occur if two (2) different Field-of-View (FOV) settings are registered in a protocol using Multi-Reconstruction. This could cause the image generated to be displayed with the wrong scale…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 12 years and passes through 4 companies; a new generation was cleared every 2.1 years on median.
  • 2 of the 9 ancestors have a recall of any class.
  • Of its descendants, K102677 (Neurologica Corporation, 2011) has gone furthest, with 9 descendants of its own.
  • 3 other devices also cite its predicate K040902.

How does its category compare?

All JAK devices

JAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · JAK

27in 2025

2007: 142008: 262009: 152010: 72011: 162012: 282013: 172014: 302015: 302016: 252017: 292018: 242019: 282020: 302021: 202022: 302023: 272024: 262025: 272026 (partial year): 21
2007high 30 (2014) · low 7 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JAK

141in 2025

2007: 27 days median2008: 42 days median2009: 31 days median2010: 92 days median2011: 155 days median2012: 121 days median2013: 132 days median2014: 200 days median2015: 140 days median2016: 129 days median2017: 96 days median2018: 114 days median2019: 94 days median2020: 112 days median2021: 145 days median2022: 131 days median2023: 139 days median2024: 141 days median2025: 141 days median2026 (partial year): 167 days median
2007high 200 (2014) · low 27 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JAK

17in 2025

2007: 112008: 162009: 292010: 512011: 342012: 232013: 112014: 102015: 282016: 442017: 332018: 102019: 52020: 82021: 152022: 92023: 92024: 202025: 172026 (partial year): 23
2007high 51 (2010) · low 5 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JAK

219in 2025

2007: 762008: 1202009: 1052010: 1192011: 2052012: 1922013: 4142014: 3082015: 4542016: 3652017: 3382018: 5432019: 2332020: 1772021: 2612022: 1992023: 3102024: 2122025: 219
2007high 543 (2018) · low 76 (2007)2025

MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200714271176
2008264216120
2009153129105
201079251119
20111615534205
20122812123192
20131713211414
20143020010308
20153014028454
20162512944365
2017299633338
20182411410543
201928945233
2020301128177
20212014515261
2022301319199
2023271399310
20242614120212
20252714117219
20262116723—

What is it indicated for?

The ECLOS Computed Tomography system is an x-ray imaging device that produces cross-sectional images of the body at different angles. The system reconstructs, processes, displays, and stores the collected images. The device output can provide an aid to diagnosis when used by a qualified physician and is intended for general purpose CT applications.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K071806: Eclos Computed Tomography X-Ray System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K071806

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026