510(k) Report

510(k) · Cleared

Recalled · Class I · 2016

Avea Ventilator

K103211510(k) TraditionalCleared May 12, 2011192-day reviewClass II21 CFR 868.5895Recalls 15 (14 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Care Fusion · CBK Ventilator, Continuous, Facility Use

Cleared on May 12, 2011 as substantially equivalent to K083693 (Covidien, Formerly Nellcor Puritan Bennett, Inc., 2009) and 1 other predicate after a 192-day review. Its family tree reaches back 12 generations to 1991. 11 of the 79 devices in its family, counting itself, have a Class I recall. 5 later devices descend from it. It has been recalled 15 times, including 14 Class I recalls.

Decided
May 12, 2011
Review
192 days
Class
Class II
Product code
CBK
Recalls
15 (14 Class I)
Predicates
2

Its longest line of descent runs back 12 generations to K902859 (1991). 73 ancestors in all, the oldest K883038 (1988). 5 later devices descend from it, 2 citing it directly. 11 of the 79 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 1998: 9 other ancestors, 3 with a Class I recall32007: 1 other ancestor2000: 3 other ancestors, 1 with a Class I recall11994: 3 other ancestors2006: 1 other ancestor2004: 5 other ancestors, 1 with a Class I recall12002: 4 other ancestors2005: 2 other ancestors2001: 5 other ancestors1990: 5 other ancestors2003: 2 other ancestors1999: 5 other ancestors1996: 2 other ancestors1997: 3 other ancestors1995: 3 other ancestors1992: 2 other ancestors1991: 4 other ancestors1993: 1 other ancestor1988: 1 other ancestor2017: 2 descendants cleared, 2 with a Class I recall22014: 1 descendant cleared, 1 with a Class I recall12024: 1 descendant cleared2020: 1 descendant cleared, 1 with a Class I recall1K902859 · Servo Ventilator 300 · Siemens Life Support Systems · 1991 · recalledK960010 · Servo Ventilator 300 Computer Interface · Siemens Elema AB · 1996K970839 · Servo Ventilator 300A · Siemens Elema AB · 1997 · recalledK992788 · Bear Cub 750 PSV · Bear Medical Systems, Inc. · 1999K013642 · AVEA · Bird Products Corp. · 2002 · Class I recallK032451 · Bird Tbird Vela Ventilator · Bird Products Corp. · 2004 · recalled×3: 3 generations cleared close together, K052554 (2005), K053270 (2006), K061627 (2006) K063404 · Servo-I Ventilator System, Models 64, 87 and 800 · Maquet Critical Care AB · 2007K073179 · Servo-I Ventilator System Model 64 87 800 E4073, Heliox Option, Model 6675585 · Maquet Critical Care AB · 2008K083693 · PB 840 Ventilator System with Leak Compensation Option, Model 840 · Covidien, Formerly Nellcor Puritan Bennett, Inc. · 20091990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 3 other ancestors, 1 with a Class I recall13 generations back: 4 other ancestors, 1 with a Class I recall14 generations back: 8 other ancestors5 generations back: 13 other ancestors, 2 with a Class I recall26 generations back: 14 other ancestors7 generations back: 4 other ancestors, 1 with a Class I recall18 generations back: 6 other ancestors9 generations back: 5 other ancestors10 generations back: 2 other ancestors11 generations back: 1 other ancestor 1 generation forward: 2 descendants, 2 with a Class I recall22 generations forward: 2 descendants, 1 with a Class I recall13 generations forward: 1 descendant, 1 with a Class I recall1 K083693 · PB 840 Ventilator System with Leak Compensation Option, Model 840 · Covidien, Formerly Nellcor Puritan Bennett, Inc. · 2009K073179 · Servo-I Ventilator System Model 64 87 800 E4073, Heliox Option, Model 6675585 · Maquet Critical Care AB · 2008K063404 · Servo-I Ventilator System, Models 64, 87 and 800 · Maquet Critical Care AB · 2007K061627 · Modification to I Vent 201 · Versamed Medical Systems, Inc. · 2006K053270 · IVENT 201 · Versamed Medical Systems, Inc. · 2006K052554 · Modification to: Ivent 201 Portable Ventilator · Versamed Medical Systems, Inc. · 2005K032451 · Bird Tbird Vela Ventilator · Bird Products Corp. · 2004 · recalledK013642 · AVEA · Bird Products Corp. · 2002 · Class I recallK992788 · Bear Cub 750 PSV · Bear Medical Systems, Inc. · 1999K970839 · Servo Ventilator 300A · Siemens Elema AB · 1997 · recalledK960010 · Servo Ventilator 300 Computer Interface · Siemens Elema AB · 1996K902859 · Servo Ventilator 300 · Siemens Life Support Systems · 1991 · recalled−10−50
  1. Root · 12 generations backK902859 Servo Ventilator 300Siemens Life Support Systems · 1991 · Recalled
  2. 8 generations between
  3. 3 generations backK063404 Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB · 2007
  4. 2 generations backK073179 Servo-I Ventilator System Model 64 87 800 E4073, Heliox Option…Maquet Critical Care AB · 2008
  5. 1 generation backK083693 PB 840 Ventilator System with Leak Compensation Option, Model 840Covidien, Formerly Nellcor Puritan Bennett, Inc. · 2009
  6. This deviceK103211 Avea VentilatorCare Fusion · 2011
  7. Descendant · cites it directly · 2 of its ownK131252 Puritan Bennett 980 Series Ventilator SystemCovidien · 2014 · Recalled (Class I)
  8. Descendant · 2 generations on · 1 of its ownK162738 Puritan Bennett 980 Ventilator SystemCovidien · 2017 · Recalled (Class I)
  9. Descendant · cites it directly · 1 of its ownK162832 731 Series VentilatorsZOLL Medical Corporation · 2017 · Recalled (Class I)
  10. Descendant · 2 generations on · 0 of its ownK233486 731 Series VentilatorZOLL Medical Corporation · 2024
  11. Descendant · 3 generations on · 0 of its ownK193056 Puritan Bennett 980 Series Ventilator SystemCovidien, LLC · 2020 · Recalled (Class I)
Show all 12 generations
  1. Root · 12 generations backK902859 Servo Ventilator 300Siemens Life Support Systems · 1991 · Recalled
  2. 11 generations backK960010 Servo Ventilator 300 Computer InterfaceSiemens Elema AB · 1996
  3. 10 generations backK970839 Servo Ventilator 300ASiemens Elema AB · 1997 · Recalled
  4. 9 generations backK992788 Bear Cub 750 PSVBear Medical Systems, Inc. · 1999
  5. 8 generations backK013642 AVEABird Products Corp. · 2002 · Recalled (Class I)
  6. 7 generations backK032451 Bird Tbird Vela VentilatorBird Products Corp. · 2004 · Recalled
  7. 6 generations backK052554 Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc. · 2005
  8. 5 generations backK053270 IVENT 201Versamed Medical Systems, Inc. · 2006
  9. 4 generations backK061627 Modification to I Vent 201Versamed Medical Systems, Inc. · 2006
  10. 3 generations backK063404 Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB · 2007
  11. 2 generations backK073179 Servo-I Ventilator System Model 64 87 800 E4073, Heliox Option…Maquet Critical Care AB · 2008
  12. 1 generation backK083693 PB 840 Ventilator System with Leak Compensation Option, Model 840Covidien, Formerly Nellcor Puritan Bennett, Inc. · 2009
  13. This deviceK103211 Avea VentilatorCare Fusion · 2011

Class I recalls in this family

Most influential descendants

Showing 5 of 5 · See all
  • K131252Puritan Bennett 980 Series Ventilator SystemCovidien · 2014 · cites it directly2descendants
  • K162738Puritan Bennett 980 Ventilator SystemCovidien · 2017 · 2 generations on1descendant
  • K162832731 Series VentilatorsZOLL Medical Corporation · 2017 · cites it directly1descendant
  • K233486731 Series VentilatorZOLL Medical Corporation · 2024 · 2 generations on0descendants
  • K193056Puritan Bennett 980 Series Ventilator SystemCovidien, LLC · 2020 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−12K902859Servo Ventilator 300Siemens Life Support Systems19913
−11K960010Servo Ventilator 300 Computer InterfaceSiemens Elema AB1996—
−10K970839Servo Ventilator 300ASiemens Elema AB19974
−9K992788Bear Cub 750 PSVBear Medical Systems, Inc.1999—
−8K013642AVEABird Products Corp.2002Class I
−7K032451Bird Tbird Vela VentilatorBird Products Corp.20041
−6K052554Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc.2005—
−5K053270IVENT 201Versamed Medical Systems, Inc.2006—
−4K061627Modification to I Vent 201Versamed Medical Systems, Inc.2006—
−3K063404Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB2007—
−2K073179Servo-I Ventilator System Model 64 87 800 E4073, Heliox Option, Model 6675585Maquet Critical Care AB2008—
−1K083693PB 840 Ventilator System with Leak Compensation Option, Model 840Covidien, Formerly Nellcor Puritan Bennett, Inc.2009—
0 (this device)K103211Avea VentilatorCare Fusion2011—
+1K131252Puritan Bennett 980 Series Ventilator SystemCovidien2014Class I
+2K162738Puritan Bennett 980 Ventilator SystemCovidien2017Class I
+1K162832731 Series VentilatorsZOLL Medical Corporation2017Class I
+2K233486731 Series VentilatorZOLL Medical Corporation2024—
+3K193056Puritan Bennett 980 Series Ventilator SystemCovidien, LLC2020Class I

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198810
199050
199140
199220
199310
199430
199530
199620
199730
199893
199950
200031
200150
200240
200320
200451
200520
200610
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201411
201722
202011
202410
FIG. 1 — Lineage of K103211, 1991–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

11 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CBK device

  1. #1 K252663 Inbentus Versatilescore 16.0 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K083693PB 840 Ventilator System with Leak Compensation Option, Model 840
Summary page 1
…0001 Registration Number Device Class: Class 11 Classification Anesthesiology Panel: Predicate Device: The predicate devices are: 1. K083693: 840 Ventilator (Covidien) 2. K974176: Baby log 8000 (Drager Inc.) Device The AVEA is a se…
Covidien, Formerly Nellcor Puritan Bennett, Inc.2009—
*K974176Babylog 8000 Plus
Summary page 1
…assification Anesthesiology Panel: Predicate Device: The predicate devices are: 1. K083693: 840 Ventilator (Covidien) 2. K974176: Baby log 8000 (Drager Inc.) Device The AVEA is a servo-controlled, software-driven ventilator. It has a Descr…
Drager, Inc.19981

What descends from it? (5)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K131252Puritan Bennett 980 Series Ventilator System Class ICovidien20142
K162832731 Series Ventilators Class IZOLL Medical Corporation20171

Has anything in its family been recalled? (11 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 17, 2016Class IZ-1888-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1895-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1896-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1899-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1892-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1897-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1898-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1894-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1889-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1891-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1890-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1893-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
Apr 3, 2015Class IZ-1609-2015Process controlA pressure transducer failure can develop, activating a false Extended High Ppeak or Circuit Occlusion Alarm. The Safety Valve will open to ambient air and the unit will stop ventilating, allowing spontaneous breathing patients to…
Sep 5, 2013Class IZ-2273-2013Component design/selectionCareFusion has identified a potential risk associated with AVEA¿ ventilators when used at higher altitudes. A proactive complaint review identified an error in the barometric pressure compensation. CareFusion is voluntarily initiating a…
Sep 8, 2011Not classifiedZ-0510-2012Nonconforming Material/ComponentThe recall was initiated because Carefusion has identified a potential risk associated with certain AVEA ventilators and affected replacement parts manufactured between March 1, 2009 and June 30, 2011. Carefusion is voluntarily initiating…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K001646Puritan-Bennett 840 Ventilator System with Neomode OptionPuritan Bennett Corp. · 2000 · 2 generations back · ◆ in the 2000 ancestors bar of FIG. 11 Class I recall
  • K041223Modification to Servo-I Ventilator System, Model 64 87 800 E407EMaquet Critical Care AB · 2004 · 3 generations back · ◆ in the 2004 ancestors bar of FIG. 11 Class I recall
  • K013642AVEABird Products Corp. · 2002 · 4 generations back · ◆ on the line of descent in FIG. 113 Class I recalls
  • K984535Puritan-Bennett 840 Ventilatory System with Bilevel OptionPuritan Bennett Corp. · 1998 · 5 generations back · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall
  • K970460Nellcor Puritan Bennett, 840 Ventilator System (Model 840)Puritan Bennett Corp. · 1998 · 5 generations back · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall
  • K981072Esprit VentilatorRespironics, Inc. · 1998 · 7 generations back · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall
  • K162832731 Series VentilatorsZOLL Medical Corporation · 2017 · Cites it directly · ◆ in the 2017 descendants bar of FIG. 11 Class I recall
  • K131252Puritan Bennett 980 Series Ventilator SystemCovidien · 2014 · Cites it directly · ◆ in the 2014 descendants bar of FIG. 13 Class I recalls
  • K162738Puritan Bennett 980 Ventilator SystemCovidien · 2017 · 2 generations on · ◆ in the 2017 descendants bar of FIG. 11 Class I recall
  • K193056Puritan Bennett 980 Series Ventilator SystemCovidien, LLC · 2020 · 3 generations on · ◆ in the 2020 descendants bar of FIG. 117 Class I recalls

What does this lineage say?

  • The line of descent spans 20 years and passes through 8 companies; a new generation was cleared every 1.5 years on median.
  • 21 of the 73 ancestors have a recall of any class; 6 have a Class I recall.
  • Of its descendants, K131252 (Covidien, 2014) has gone furthest, with 2 descendants of its own.

How does its category compare?

All CBK devices

CBK Ventilator, Continuous, Facility Use: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · CBK

4in 2025

2007: 112008: 182009: 122010: 142011: 132012: 172013: 52014: 52015: 72016: 42017: 62018: 42019: 82020: 52021: 62023: 52024: 92025: 42026 (partial year): 3
2007high 18 (2008) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CBK

163in 2025

2007: 142 days median2008: 115 days median2009: 122 days median2010: 150 days median2011: 192 days median2012: 207 days median2013: 277 days median2014: 439 days median2015: 266 days median2016: 323 days median2017: 280 days median2018: 183 days median2019: 435 days median2020: 176 days median2021: 267 days median2023: 309 days median2024: 203 days median2025: 163 days median2026 (partial year): 235 days median
2007high 439 (2014) · low 115 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CBK

14in 2024

2007: 172008: 232009: 82010: 92011: 122012: 2, 1 Class I2013: 5, 2 Class I2014: 5, 4 Class I2015: 6, 4 Class I2016: 4, 1 Class I2017: 12018: 3, 3 Class I2019: 14, 13 Class I2020: 42021: 21, 19 Class I2022: 8, 4 Class I2023: 4, 3 Class I2024: 14, 14 Class I2026 (partial year): 15, 13 Class I
2007high 23 (2008) · low 0 (2025)2026

Class I (81 since 2007) Class II/III not classified

Adverse event reports per year · CBK

13,991in 2025

2007: 1,5312008: 1,9332009: 1,7662010: 1,7992011: 1,8772012: 5,5092013: 7,9212014: 7,6002015: 11,8762016: 16,0562017: 14,4512018: 9,8492019: 9,1002020: 11,0962021: 13,3222022: 15,9742023: 24,9282024: 20,3362025: 13,991
2007high 24,928 (2023) · low 1,531 (2007)2025

MAUDE reports naming product code CBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711142171,531
200818115231,933
20091212281,766
20101415091,799
201113192121,877
2012172072 (1)5,509
201352775 (2)7,921
201454395 (4)7,600
201572666 (4)11,876
201643234 (1)16,056
20176280114,451
201841833 (3)9,849
2019843514 (13)9,100
20205176411,096
2021626721 (19)13,322
20220—8 (4)15,974
202353094 (3)24,928
2024920314 (14)20,336
20254163013,991
2026323515 (13)—

What is it indicated for?

The AVEA is intended to provide continuous respiratory support in an institutional health care environment (e.g. hospitals). It may be used on neonatal through adult patients. It should only be operated by properly trained clinical personnel, under the direction of a physician.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K103211: Avea Ventilator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K103211

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026