510(k) Report

510(k) · Cleared

Recalled · Class I · 2016

AVEA

K013642510(k) TraditionalCleared May 22, 2002198-day reviewClass II21 CFR 868.5895Recalls 19 (13 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bird Products Corp. · CBK Ventilator, Continuous, Facility Use

Cleared on May 22, 2002 as substantially equivalent to K970460 (Puritan Bennett Corp., 1998) and 6 other predicates after a 198-day review. Its family tree reaches back 4 generations to 1991. 42 of the 154 devices in its family, counting itself, have a Class I recall. 133 later devices descend from it. It has been recalled 19 times, including 13 Class I recalls.

Decided
May 22, 2002
Review
198 days
Class
Class II
Product code
CBK
Recalls
19 (13 Class I)
Predicates
7

Its longest line of descent runs back 4 generations to K902859 (1991). 20 ancestors in all, the oldest K895541 (1990). 133 later devices descend from it, 5 citing it directly. 42 of the 154 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2000: 1 other ancestor1999: 1 other ancestor1998: 3 other ancestors, 1 with a Class I recall11996: 1 other ancestor1995: 2 other ancestors1994: 2 other ancestors1992: 2 other ancestors1991: 1 other ancestor1990: 3 other ancestors2008: 8 descendants cleared, 1 with a Class I recall12012: 11 descendants cleared, 4 with a Class I recall42004: 2 descendants cleared2002: 1 descendant cleared2007: 3 descendants cleared, 1 with a Class I recall12006: 4 descendants cleared2005: 1 descendant cleared2011: 12 descendants cleared, 7 with a Class I recall72014: 6 descendants cleared, 1 with a Class I recall12010: 5 descendants cleared, 1 with a Class I recall12025: 4 descendants cleared2009: 5 descendants cleared, 1 with a Class I recall12021: 7 descendants cleared, 3 with a Class I recall32015: 8 descendants cleared, 1 with a Class I recall12017: 11 descendants cleared, 5 with a Class I recall52013: 10 descendants cleared, 4 with a Class I recall42016: 8 descendants cleared, 3 with a Class I recall32019: 7 descendants cleared, 3 with a Class I recall32024: 5 descendants cleared2018: 3 descendants cleared, 1 with a Class I recall12026: 5 descendants cleared2020: 4 descendants cleared, 3 with a Class I recall32023: 2 descendants cleared, 1 with a Class I recall12022: 1 descendant clearedK902859 · Servo Ventilator 300 · Siemens Life Support Systems · 1991 · recalledK960010 · Servo Ventilator 300 Computer Interface · Siemens Elema AB · 1996K970839 · Servo Ventilator 300A · Siemens Elema AB · 1997 · recalledK992788 · Bear Cub 750 PSV · Bear Medical Systems, Inc. · 19991990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 5 other ancestors, 1 with a Class I recall12 generations back: 10 other ancestors3 generations back: 1 other ancestor 1 generation forward: 5 descendants2 generations forward: 12 descendants, 1 with a Class I recall13 generations forward: 23 descendants, 7 with a Class I recall74 generations forward: 26 descendants, 11 with a Class I recall115 generations forward: 25 descendants, 8 with a Class I recall86 generations forward: 19 descendants, 7 with a Class I recall77 generations forward: 11 descendants, 4 with a Class I recall48 generations forward: 6 descendants9 generations forward: 2 descendants, 1 with a Class I recall110 generations forward: 3 descendants, 1 with a Class I recall111 generations forward: 1 descendant K992788 · Bear Cub 750 PSV · Bear Medical Systems, Inc. · 1999K970839 · Servo Ventilator 300A · Siemens Elema AB · 1997 · recalledK960010 · Servo Ventilator 300 Computer Interface · Siemens Elema AB · 1996K902859 · Servo Ventilator 300 · Siemens Life Support Systems · 1991 · recalled0+5+10
  1. Root · 4 generations backK902859 Servo Ventilator 300Siemens Life Support Systems · 1991 · Recalled
  2. 3 generations backK960010 Servo Ventilator 300 Computer InterfaceSiemens Elema AB · 1996
  3. 2 generations backK970839 Servo Ventilator 300ASiemens Elema AB · 1997 · Recalled
  4. 1 generation backK992788 Bear Cub 750 PSVBear Medical Systems, Inc. · 1999
  5. This deviceK013642 AVEABird Products Corp. · 2002
  6. Descendant · cites it directly · 114 of its ownK032451 Bird Tbird Vela VentilatorBird Products Corp. · 2004 · Recalled
  7. Descendant · 2 generations on · 112 of its ownK052554 Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc. · 2005
  8. Descendant · 2 generations on · 87 of its ownK053270 IVENT 201Versamed Medical Systems, Inc. · 2006
  9. Descendant · 3 generations on · 86 of its ownK061627 Modification to I Vent 201Versamed Medical Systems, Inc. · 2006
  10. Descendant · 4 generations on · 61 of its ownK063404 Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB · 2007

Showing 5 of 133 descendants. See all descendants

Descendants cleared per year

2002: 12004: 22005: 12006: 42007: 32008: 82009: 52010: 52011: 122012: 112013: 102014: 62015: 82016: 82017: 112018: 32019: 72020: 42021: 72022: 12023: 22024: 52025: 42026: 5
2002high 12 (2011) · low 0 (2003)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 133 · See all
  • K032451Bird Tbird Vela VentilatorBird Products Corp. · 2004 · cites it directly114descendants
  • K052554Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc. · 2005 · 2 generations on112descendants
  • K053270IVENT 201Versamed Medical Systems, Inc. · 2006 · 2 generations on87descendants
  • K061627Modification to I Vent 201Versamed Medical Systems, Inc. · 2006 · 3 generations on86descendants
  • K063404Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB · 2007 · 4 generations on61descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K902859Servo Ventilator 300Siemens Life Support Systems19913
−3K960010Servo Ventilator 300 Computer InterfaceSiemens Elema AB1996—
−2K970839Servo Ventilator 300ASiemens Elema AB19974
−1K992788Bear Cub 750 PSVBear Medical Systems, Inc.1999—
0 (this device)K013642AVEABird Products Corp.2002—
+1K032451Bird Tbird Vela VentilatorBird Products Corp.20041
+2K052554Modification to: Ivent 201 Portable VentilatorVersamed Medical Systems, Inc.2005—
+2K053270IVENT 201Versamed Medical Systems, Inc.2006—
+3K061627Modification to I Vent 201Versamed Medical Systems, Inc.2006—
+4K063404Servo-I Ventilator System, Models 64, 87 and 800Maquet Critical Care AB2007—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199030
199110
199220
199420
199520
199610
199831
199910
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200210
200420
200510
200640
200731
200881
200951
201051
2011127
2012114
2013104
201461
201581
201683
2017115
201831
201973
202043
202173
202210
202321
202450
202540
202650
FIG. 1 — Lineage of K013642, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

42 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CBK device

  1. #1 K252663 Inbentus Versatilescore 16.0 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (7)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K970460Nellcor Puritan Bennett, 840 Ventilator System (Model 840)
Summary page 2
…predicate device. The predicate devices used for substantial equivalence determination are as follows: 510(k) Number Trade or proprietary or model name Manufacturer 1 K970460 840 Puritan Bennett 2 K961687 EVITA 4 Drager 3 K902859 SERVO VENTILATOR 300 SIEMENS 4 K992788 Bear Cub 750 PSV Bear Medical Sy…
Puritan Bennett Corp.1998Class I
*K961687EVITA 4
Summary page 2
…e devices used for substantial equivalence determination are as follows: 510(k) Number Trade or proprietary or model name Manufacturer 1 K970460 840 Puritan Bennett 2 K961687 EVITA 4 Drager 3 K902859 SERVO VENTILATOR 300 SIEMENS 4 K992788 Bear Cub 750 PSV Bear Medical Systems 5 K983981 Bear 1000es Be…
Drager, Inc.1996—
*K902859Servo Ventilator 300
Summary page 2
…tial equivalence determination are as follows: 510(k) Number Trade or proprietary or model name Manufacturer 1 K970460 840 Puritan Bennett 2 K961687 EVITA 4 Drager 3 K902859 SERVO VENTILATOR 300 SIEMENS 4 K992788 Bear Cub 750 PSV Bear Medical Systems 5 K983981 Bear 1000es Bear Medical Systems 6 K993…
Siemens Life Support Systems19913
*K992788Bear Cub 750 PSV
Summary page 2
…llows: 510(k) Number Trade or proprietary or model name Manufacturer 1 K970460 840 Puritan Bennett 2 K961687 EVITA 4 Drager 3 K902859 SERVO VENTILATOR 300 SIEMENS 4 K992788 Bear Cub 750 PSV Bear Medical Systems 5 K983981 Bear 1000es Bear Medical Systems 6 K993449 VIP Gold/Sterling Bird Products Corp…
Bear Medical Systems, Inc.1999—
*K983981Bear 1000, Veolar W Leonardo Graphics, Bicore CP-2000, Bicore CP-100, HI-LO Jet ET Tube
Summary page 2
…el name Manufacturer 1 K970460 840 Puritan Bennett 2 K961687 EVITA 4 Drager 3 K902859 SERVO VENTILATOR 300 SIEMENS 4 K992788 Bear Cub 750 PSV Bear Medical Systems 5 K983981 Bear 1000es Bear Medical Systems 6 K993449 VIP Gold/Sterling Bird Products Corporation 7 KO00706 DATEX-OHMEDA AESTIVA/S with 710…
Bear Medical Systems, Inc.1998—
*K993449Bird V.I.P. Gold/Sterling
Summary page 2
…Bennett 2 K961687 EVITA 4 Drager 3 K902859 SERVO VENTILATOR 300 SIEMENS 4 K992788 Bear Cub 750 PSV Bear Medical Systems 5 K983981 Bear 1000es Bear Medical Systems 6 K993449 VIP Gold/Sterling Bird Products Corporation 7 KO00706 DATEX-OHMEDA AESTIVA/S with 7100 DATEX: OHMEDA Ventilator Anesthesia Syste…
Bird Products Corp.19992
*K000706Datex-Ohmeda Aestiva/5 with 7100 VentilatorDatex-Ohmeda, Inc.20004

Also cleared against K970460: 6 other devices →

What descends from it? (133)

See all 133

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K032451Bird Tbird Vela VentilatorBird Products Corp.2004114
K022674Bird Avea VentilatorBird Products Corp.200258
K081837Avea VentilatorCardinal Health 207, Inc.200813
K110083V200 Ventilator with Aprv Mode, Esprit Ventilator with Aprv ModeRespironics California, Inc.20120
K062793Servo-I Ventilator System, Model 64 87 800 E407E; Nava OptionMaquet Critical Care AB20070

Has anything in its family been recalled? (42 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 17, 2016Class IZ-1888-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1895-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1896-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1899-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1892-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1897-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1898-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1894-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1889-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1891-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1890-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
May 17, 2016Class IZ-1893-2016Under Investigation by firmCareFusion has identified a potential risk associated with AVEA Ventilator caused by an incorrect F1 fuse on the AVEA Ventilator Transducer Communication Alarm (TCA) Board which may fail/blow, causing loss of power to the User Interface…
Sep 5, 2013Class IZ-2273-2013Component design/selectionCareFusion has identified a potential risk associated with AVEA¿ ventilators when used at higher altitudes. A proactive complaint review identified an error in the barometric pressure compensation. CareFusion is voluntarily initiating a…
Sep 8, 2011Not classifiedZ-0510-2012Nonconforming Material/ComponentThe recall was initiated because Carefusion has identified a potential risk associated with certain AVEA ventilators and affected replacement parts manufactured between March 1, 2009 and June 30, 2011. Carefusion is voluntarily initiating…
Dec 17, 2007Not classifiedZ-0982-2008Component design/selectionAlarm Failure -- There is a potential of alarms not being activated subsequent to specific electronic faults that may cause INOP condition.
Dec 17, 2007Not classifiedZ-0983-2008Component design/selectionAlarm Failure -- There is a potential of alarms not being activated subsequent to specific electronic faults that may cause INOP condition.
Dec 17, 2007Not classifiedZ-0984-2008Component design/selectionAlarm Failure -- There is a potential of alarms not being activated subsequent to specific electronic faults that may cause INOP condition.
Dec 17, 2007Not classifiedZ-0986-2008Component design/selectionAlarm Failure -- There is a potential of alarms not being activated subsequent to specific electronic faults that may cause INOP condition.
Dec 17, 2007Not classifiedZ-0985-2008Component design/selectionAlarm Failure -- There is a potential of alarms not being activated subsequent to specific electronic faults that may cause INOP condition.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K970460Nellcor Puritan Bennett, 840 Ventilator System (Model 840)Puritan Bennett Corp. · 1998 · Direct predicate · ◆ in the 1998 ancestors bar of FIG. 11 Class I recall
  • K070594Palmtop Ventilator, Models PTV-8, PTV-10Pulmonetic Systems, Inc. · 2007 · 2 generations on · ◆ in the 2007 descendants bar of FIG. 12 Class I recalls
  • K090888Newport HT70 Family of VentilatorsNewport Medical Instruments, Inc. · 2009 · 3 generations on · ◆ in the 2009 descendants bar of FIG. 13 Class I recalls
  • K093261MOVESThornhill Research, Inc. · 2010 · 3 generations on · ◆ in the 2010 descendants bar of FIG. 12 Class I recalls
  • K111146Newport HT70 VentilatorNewport Medical Instruments, Inc. · 2011 · 3 generations on · ◆ in the 2011 descendants bar of FIG. 14 Class I recalls
  • K162877VOCSN Unified Respiratory SystemVentec Life Systems, Inc. · 2017 · 3 generations on · ◆ in the 2017 descendants bar of FIG. 114 Class I recalls
  • K162832731 Series VentilatorsZOLL Medical Corporation · 2017 · 3 generations on · ◆ in the 2017 descendants bar of FIG. 11 Class I recall
  • K131774Hamilton-G5Hamilton Medical AG · 2013 · 3 generations on · ◆ in the 2013 descendants bar of FIG. 12 Class I recalls
  • K131252Puritan Bennett 980 Series Ventilator SystemCovidien · 2014 · 3 generations on · ◆ in the 2014 descendants bar of FIG. 13 Class I recalls
  • K072885Carina System, Model 8419350; Carina Basic Device, Model 5704110Draeger Medical AG & Co. KG · 2008 · 4 generations on · ◆ in the 2008 descendants bar of FIG. 11 Class I recall
  • K111610Trilogy Series Ventilator with OximetryRespironics, Inc. · 2011 · 4 generations on · ◆ in the 2011 descendants bar of FIG. 12 Class I recalls
  • K103211Avea VentilatorCare Fusion · 2011 · 4 generations on · ◆ in the 2011 descendants bar of FIG. 114 Class I recalls

Nearest 12 of 41 shown.

What does this lineage say?

  • The line of descent spans 11 years and passes through 4 companies; a new generation was cleared every 2.7 years on median.
  • 6 of the 20 ancestors have a recall of any class; 1 has a Class I recall.
  • Of its descendants, K032451 (Bird Products Corp., 2004) has gone furthest, with 114 descendants of its own.
  • 6 other devices also cite its predicate K970460.

How does its category compare?

All CBK devices

CBK Ventilator, Continuous, Facility Use: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CBK

4in 2025

2007: 112008: 182009: 122010: 142011: 132012: 172013: 52014: 52015: 72016: 42017: 62018: 42019: 82020: 52021: 62023: 52024: 92025: 42026 (partial year): 3
2007high 18 (2008) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CBK

163in 2025

2007: 142 days median2008: 115 days median2009: 122 days median2010: 150 days median2011: 192 days median2012: 207 days median2013: 277 days median2014: 439 days median2015: 266 days median2016: 323 days median2017: 280 days median2018: 183 days median2019: 435 days median2020: 176 days median2021: 267 days median2023: 309 days median2024: 203 days median2025: 163 days median2026 (partial year): 235 days median
2007high 439 (2014) · low 115 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CBK

14in 2024

2007: 172008: 232009: 82010: 92011: 122012: 2, 1 Class I2013: 5, 2 Class I2014: 5, 4 Class I2015: 6, 4 Class I2016: 4, 1 Class I2017: 12018: 3, 3 Class I2019: 14, 13 Class I2020: 42021: 21, 19 Class I2022: 8, 4 Class I2023: 4, 3 Class I2024: 14, 14 Class I2026 (partial year): 15, 13 Class I
2007high 23 (2008) · low 0 (2025)2026

Class I (81 since 2007) Class II/III not classified

Adverse event reports per year · CBK

13,991in 2025

2007: 1,5312008: 1,9332009: 1,7662010: 1,7992011: 1,8772012: 5,5092013: 7,9212014: 7,6002015: 11,8762016: 16,0562017: 14,4512018: 9,8492019: 9,1002020: 11,0962021: 13,3222022: 15,9742023: 24,9282024: 20,3362025: 13,991
2007high 24,928 (2023) · low 1,531 (2007)2025

MAUDE reports naming product code CBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711142171,531
200818115231,933
20091212281,766
20101415091,799
201113192121,877
2012172072 (1)5,509
201352775 (2)7,921
201454395 (4)7,600
201572666 (4)11,876
201643234 (1)16,056
20176280114,451
201841833 (3)9,849
2019843514 (13)9,100
20205176411,096
2021626721 (19)13,322
20220—8 (4)15,974
202353094 (3)24,928
2024920314 (14)20,336
20254163013,991
2026323515 (13)—

What is it indicated for?

The AVEA is intended to provide continuous respiratory support in an institutional health care environment (e.g. hospitals). It may be used on adult, pediatric, and neonatal patients. It should only be operated by properly trained clinical personnel, under the direction of a physician.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K013642: AVEA.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K013642

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026