510(k) · Cleared
Recalled · Class II · 2013Reliance Endoscope Processing System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
STERIS Corporation · NZA Accessories, Germicide, Cleaning, For Endoscopes
Cleared on Mar 16, 2011 as substantially equivalent to K102244 (STERIS Corporation, 2010) after a 28-day review. Its family tree reaches back 2 generations to 2004. It has been recalled once.
- Decided
- Mar 16, 2011
- Review
- 28 days
- Class
- Class II
- Product code
- NZA
- Recalls
- 1
- Predicates
- 1
Its longest line of descent runs back 2 generations to K040049 (2004). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in NZA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new NZA device
- #1 K230560 enspire 300 Series Automated Endoscope…score 9.6 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K102244 | Reliance Endoscope Processing SystemSummary page 2…cation Name: 21 CFR 876.1500 Endoscope and Accessories 2. Predicate Device Reliance Endoscope Processing System K102244 3. Description of Device The Reliance Endoscope Processing System is an economical, easy-to-use high level disinfec… | 2010 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Aug 29, 2013 | Class II | Z-2263-2013 | Use error | The air pipe that delivers unfiltered ambient air from the procedure room into the water bottle on the listed FUJINON G5 & G8 type flexible GI endoscopes does not connect to the main air/water channel within the light guide (LG)… |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 7 years and passes through 1 company; a new generation was cleared every 6.0 years on median.
- 2 of the 2 ancestors have a recall of any class.
- 2 other devices also cite its predicate K102244.
How does its category compare?
All NZA devicesNZA Accessories, Germicide, Cleaning, For Endoscopes: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · NZA
2in 2023
2026 to Oct 25, outlined.
Median 510(k) review, days · NZA
Too few NZA 510(k)s in any year since 2007 to give a median.
Recalls per year · NZA
No recall names NZA since 2007.
Adverse event reports per year · NZA
2in 2022
MAUDE reports naming product code NZA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 1 | — | 0 | 1 |
| 2011 | 1 | — | 0 | 1 |
| 2012 | 0 | — | 0 | 14 |
| 2013 | 1 | — | 0 | 11 |
| 2014 | 0 | — | 0 | 6 |
| 2015 | 0 | — | 0 | 10 |
| 2016 | 0 | — | 0 | 21 |
| 2017 | 0 | — | 0 | 9 |
| 2018 | 0 | — | 0 | 8 |
| 2019 | 0 | — | 0 | 2 |
| 2020 | 1 | — | 0 | 1 |
| 2021 | 1 | — | 0 | 4 |
| 2022 | 1 | — | 0 | 2 |
| 2023 | 2 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Reliance Endoscope Processing System is intended for washing and high level
disinfection of up to two manually pre-cleaned, immersible, reusable, heat-sensitive,
semi-critical devices such as GI flexible endoscopes, bronchoscopes and their
accessories. High level disinfection is achieved within the 50 - 57 0 C HLD Phase of the
Endoscope Processing Cycle (4 minute generation sequence followed by a 6-minute
exposure sequence).
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K110453 · printed Nov 6, 2026
Cite this page
510(k) Report. “K110453: Reliance Endoscope Processing System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K110453
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026