510(k) · Cleared
ClearedMedical Concepts Interbody Fusion System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medical Concepts, Inc. · MAX Intervertebral Fusion Device With Bone Graft, Lumbar
Cleared on Sep 13, 2011 as substantially equivalent to K090064 (Eminent Spine, 2009) and 2 other predicates after a 190-day review. Its family tree reaches back 10 generations to 1984. 1 later device descends from it.
- Decided
- Sep 13, 2011
- Review
- 190 days
- Class
- Class II
- Product code
- MAX
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 10 generations to K841189 (1984). 35 ancestors in all. 1 later device descends from it, 1 citing it directly.
- Root · 10 generations backK841189 Oec/Rezaian Spinal FixatorOrthopedic Equipment Co., Inc. · 1984
- 6 generations between
- 3 generations backK080728 LDR Spine Roi-C ImplantLdr Spine USA · 2008
- 2 generations backK083857 LDR Spine Roi-C ImplantLdr Spine USA · 2009
- 1 generation backK091088 LDR Spine Cervical Interbody Fusion SystemLdr Spine USA · 2009
- This deviceK110659 Medical Concepts Interbody Fusion SystemMedical Concepts, Inc. · 2011
- Descendant · cites it directly · 0 of its ownK254130 C.A. Medical Interbody Fusion SystemC.A. Medical, LLC · 2026
Show all 10 generations
- Root · 10 generations backK841189 Oec/Rezaian Spinal FixatorOrthopedic Equipment Co., Inc. · 1984
- 9 generations backK990148 Stackable Cage SystemDepuy Motech Acromed · 1999
- 8 generations backK003043 Surgical Titanium Mesh SystemDepuyacromed · 2001
- 7 generations backK022793 Tetris Spinal ImplantSignus Medical, LLC · 2003
- 6 generations backK031757 Peek Tetris Spinal ImplantSignus Medical, LLC · 2003
- 5 generations backK033109 Ellys and Aurys Vertebral Body ReplacementsScient'X · 2004
- 4 generations backK043479 MC+ Partial VBRLdr Spine USA · 2005
- 3 generations backK080728 LDR Spine Roi-C ImplantLdr Spine USA · 2008
- 2 generations backK083857 LDR Spine Roi-C ImplantLdr Spine USA · 2009
- 1 generation backK091088 LDR Spine Cervical Interbody Fusion SystemLdr Spine USA · 2009
- This deviceK110659 Medical Concepts Interbody Fusion SystemMedical Concepts, Inc. · 2011
Most influential descendants
Showing 1 of 1 · See all- K254130C.A. Medical Interbody Fusion SystemC.A. Medical, LLC · 2026 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −10 | K841189 | Oec/Rezaian Spinal Fixator | Orthopedic Equipment Co., Inc. | 1984 | — |
| −9 | K990148 | Stackable Cage System | Depuy Motech Acromed | 1999 | — |
| −8 | K003043 | Surgical Titanium Mesh System | Depuyacromed | 2001 | — |
| −7 | K022793 | Tetris Spinal Implant | Signus Medical, LLC | 2003 | — |
| −6 | K031757 | Peek Tetris Spinal Implant | Signus Medical, LLC | 2003 | — |
| −5 | K033109 | Ellys and Aurys Vertebral Body Replacements | Scient'X | 2004 | — |
| −4 | K043479 | MC+ Partial VBR | Ldr Spine USA | 2005 | — |
| −3 | K080728 | LDR Spine Roi-C Implant | Ldr Spine USA | 2008 | — |
| −2 | K083857 | LDR Spine Roi-C Implant | Ldr Spine USA | 2009 | — |
| −1 | K091088 | LDR Spine Cervical Interbody Fusion System | Ldr Spine USA | 2009 | — |
| 0 (this device) | K110659 | Medical Concepts Interbody Fusion System | Medical Concepts, Inc. | 2011 | — |
| +1 | K254130 | C.A. Medical Interbody Fusion System | C.A. Medical, LLC | 2026 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1996 | 2 | 0 |
| 1999 | 2 | 0 |
| 2000 | 1 | 0 |
| 2001 | 8 | 0 |
| 2002 | 4 | 0 |
| 2003 | 1 | 0 |
| 2004 | 3 | 0 |
| 2005 | 1 | 0 |
| 2008 | 2 | 0 |
| 2009 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MAX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MAX device
- #1 K203714 NuVasive Thoracolumbar Interbody Systems…score 102.5 · 24 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K090064 | Eminent Spine Interbody Fusion SystemSummary page 1…ude various cleared interbody fusion and vertebral body replacement systems: - Eminent Spine System (K090064) - MC+ (K043479, K091088)… | 2009 |
| * | K043479 | MC+ Partial VBRSummary page 1…and vertebral body replacement systems: - Eminent Spine System (K090064) - MC+ (K043479, K091088) K110659… | 2005 |
| * | K091088 | LDR Spine Cervical Interbody Fusion SystemSummary page 1…and vertebral body replacement systems: - Eminent Spine System (K090064) - MC+ (K043479, K091088) K110659… | 2009 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K254130 | C.A. Medical Interbody Fusion System | 2026 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 27 years and passes through 7 companies; a new generation was cleared every 1.7 years on median.
- 6 of the 35 ancestors have a recall of any class.
- Of its descendants, K254130 (C.A. Medical, LLC, 2026) has gone furthest, with 0 descendants of its own.
- 33 other devices also cite its predicate K090064.
How does its category compare?
All MAX devicesMAX Intervertebral Fusion Device With Bone Graft, Lumbar: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · MAX
29in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MAX
85in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MAX
5in 2025
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · MAX
811in 2025
MAUDE reports naming product code MAX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 7 | 86 | 0 | 12 |
| 2008 | 35 | 88 | 2 | 19 |
| 2009 | 31 | 102 | 9 | 90 |
| 2010 | 29 | 137 | 0 | 154 |
| 2011 | 49 | 98 | 3 | 201 |
| 2012 | 48 | 69 | 11 (1) | 327 |
| 2013 | 58 | 102 | 0 | 380 |
| 2014 | 58 | 115 | 3 | 366 |
| 2015 | 53 | 113 | 1 | 524 |
| 2016 | 64 | 124 | 6 | 647 |
| 2017 | 76 | 116 | 1 | 596 |
| 2018 | 64 | 114 | 4 | 616 |
| 2019 | 60 | 131 | 1 | 699 |
| 2020 | 56 | 106 | 0 | 640 |
| 2021 | 53 | 109 | 0 | 622 |
| 2022 | 41 | 95 | 1 | 618 |
| 2023 | 30 | 87 | 0 | 576 |
| 2024 | 38 | 91 | 1 | 729 |
| 2025 | 29 | 85 | 5 | 811 |
| 2026 | 18 | 95 | 0 | — |
What is it indicated for?
When used as a cervical intervertebral body fusion device, the Medical Concepts Interbody Fusion System is indicated for intervertebral body fusion in skeletally mature patients with degenerative disc disease (ODD) of the cervical spine with accompanying radicular symptoms at one disc level from the C2-C3 disc to the C7-TI disc. DODD is defined as discogenic pain with degeneration of the disc confirmed by history and radiographic studies. The device…
Read the full statement (312 words)
When used as a cervical intervertebral body fusion device, the Medical Concepts Interbody Fusion System is indicated for intervertebral body fusion in skeletally mature patients with degenerative disc disease (ODD) of the cervical spine with accompanying radicular symptoms at one disc level from the C2-C3 disc to the C7-TI disc. DODD is defined as discogenic pain with degeneration of the disc confirmed by history and radiographic studies. The device system is designed for use with supplemental fixation and with autograft to facilitate fusion. Patients should have at least six (6) weeks of non-operative treatment prior to treatment with an intervertebral cage.
When used as a lumbar intervertebral body fusion device, the Medical Concepts Interbody Fusion System is indicated for intervertelbral body fusion of the lumbar spine, from L2 to SI, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (ODD) with up to Grade I spondylolisthesis or retrolisthesis at the involved level(s). DOID is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The device system is designed for use with supplemental fixation and with autograft to facilitate fusion.
When used as a vertebral body replacement device, the Medical Concepts System is indicated for use to replace a vertebral body that has been resected or excised (i.e. partial or total vertebrectomy) due to tumor or trauma/fracture. The device system is intended for use in the thoracolumbar spine (from Ti to L5) and is intended for use with supplemental fixation. These devices are designed to restore the biomnechanical integrity of the anterior, middle and posterior spinal column even in the absence of fusion for a prolonged period. The device system is intended to be used with autograft or allograft bone.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K110659 · printed Nov 4, 2026
Cite this page
510(k) Report. “K110659: Medical Concepts Interbody Fusion System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K110659
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026