510(k) · Cleared
ClearedHeater-Cooler Unit Hcu 40
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Maquet Cardiopulmonary, AG · DWC Controller, Temperature, Cardiopulmonary Bypass
Cleared on Jul 1, 2013 as substantially equivalent to K031544 (Jostra AB, 2003) after a 144-day review. Its family tree reaches back 2 generations to 1988.
- Decided
- Jul 1, 2013
- Review
- 144 days
- Class
- Class II
- Product code
- DWC
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K883603 (1988). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DWC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DWC device
- #1 K220635 Heater-Cooler System 3Tscore 5.3 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K031544 | Heater Cooler Unit, Model Hcu 30Summary page 1…DWC PREDICATE DEVCE INFORMATION: The Heater-Cooler Unit HCU 40 is substantially equivalent in function and intended use to the Heater-Cooler Unit HCU 30 (K03 1544). DEVICE DESCRIPTION AND INTENDED USE: The Heater-Cooler Unit HCU 40 is used to supply temperature-controlled water to regulat… | 2003 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 25 years and passes through 3 companies; a new generation was cleared every 14.8 years on median.
- 2 of the 2 ancestors have a recall of any class.
- 2 other devices also cite its predicate K031544.
How does its category compare?
All DWC devicesDWC Controller, Temperature, Cardiopulmonary Bypass: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.
FDA decisions per year · DWC
2in 2022
2026 to Oct 25, outlined.
Median 510(k) review, days · DWC
Too few DWC 510(k)s in any year since 2007 to give a median.
Recalls per year · DWC
5in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DWC
670in 2025
MAUDE reports naming product code DWC, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 3 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 2 |
| 2010 | 1 | — | 1 | 243 |
| 2011 | 0 | — | 0 | 281 |
| 2012 | 1 | — | 2 | 351 |
| 2013 | 1 | — | 0 | 244 |
| 2014 | 1 | — | 1 | 378 |
| 2015 | 0 | — | 1 | 575 |
| 2016 | 0 | — | 1 | 787 |
| 2017 | 0 | — | 1 | 716 |
| 2018 | 0 | — | 3 | 564 |
| 2019 | 0 | — | 0 | 697 |
| 2020 | 1 | — | 0 | 548 |
| 2021 | 0 | — | 5 | 622 |
| 2022 | 2 | — | 0 | 605 |
| 2023 | 0 | — | 5 | 928 |
| 2024 | 0 | — | 0 | 555 |
| 2025 | 0 | — | 0 | 670 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The HCU 40 is intended to circulate water through heat exchange circuits to
warm or cool a patient during short duration cardiopulmonary bypass procedures
lasting 6 hours or less.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K130300 · printed Nov 4, 2026
Cite this page
510(k) Report. “K130300: Heater-Cooler Unit Hcu 40.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K130300
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026