510(k) Report

510(k) · Cleared

Cleared

CT Pulmonary Analysis

K130552510(k) TraditionalCleared Jan 13, 2014315-day reviewClass II21 CFR 892.1750

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Qi Imaging, LLC · JAK System, X-Ray, Tomography, Computed

Cleared on Jan 13, 2014 as substantially equivalent to K083227 (Vida Diagnostics, Inc., 2008) and 1 other predicate after a 315-day review. Its family tree reaches back 12 generations to 1991. 2 later devices descend from it.

Decided
Jan 13, 2014
Review
315 days
Class
Class II
Product code
JAK
Recalls
None
Predicates
2

Its longest line of descent runs back 12 generations to K913770 (1991). 165 ancestors in all, the oldest K871859 (1987). 2 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2008: 7 other ancestors2010: 1 other ancestor2007: 7 other ancestors2009: 2 other ancestors2006: 8 other ancestors2005: 10 other ancestors2004: 14 other ancestors2001: 16 other ancestors2000: 11 other ancestors1996: 9 other ancestors2003: 6 other ancestors2002: 12 other ancestors1999: 7 other ancestors1997: 8 other ancestors1998: 11 other ancestors1994: 4 other ancestors1995: 6 other ancestors1993: 2 other ancestors1987: 1 other ancestor1992: 2 other ancestors1991: 5 other ancestors1988: 2 other ancestors1990: 1 other ancestor1989: 1 other ancestor2018: 1 descendant cleared2020: 1 descendant clearedK913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991K960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK023003 · Imagechecker-CT Workstation · R2 Technology, Inc. · 2002×2: 2 generations cleared close together, K032748 (2003), K040305 (2004) K043333 · VITREA2, Version 3.7 Medical Image Processing System · Vital Images, Inc. · 2004 · recalledK052632 · VITREA2 Version 3.8 Medical Image Processing Software · Vital Images, Inc. · 2005 · recalledK061624 · Vitrea, Version 3.9 · Vital Images, Inc. · 2006 · recalledK071000 · Myrian · Intrasense · 2007K091001 · Myrian 1.4 · Intrasense · 2009K113620 · Myrian 1.11 · Intrasense · 20121990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 5 other ancestors3 generations back: 12 other ancestors4 generations back: 21 other ancestors5 generations back: 26 other ancestors6 generations back: 32 other ancestors7 generations back: 26 other ancestors8 generations back: 17 other ancestors9 generations back: 10 other ancestors10 generations back: 2 other ancestors11 generations back: 1 other ancestor 1 generation forward: 1 descendant2 generations forward: 1 descendant K113620 · Myrian 1.11 · Intrasense · 2012K091001 · Myrian 1.4 · Intrasense · 2009K071000 · Myrian · Intrasense · 2007K061624 · Vitrea, Version 3.9 · Vital Images, Inc. · 2006 · recalledK052632 · VITREA2 Version 3.8 Medical Image Processing Software · Vital Images, Inc. · 2005 · recalledK043333 · VITREA2, Version 3.7 Medical Image Processing System · Vital Images, Inc. · 2004 · recalledK040305 · VITREA2 Version 3.5 · Vital Images, Inc. · 2004K032748 · VITREA2, Version 3.4 Medical Image Processing Software · Vital Images, Inc. · 2003 · recalledK023003 · Imagechecker-CT Workstation · R2 Technology, Inc. · 2002K020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991−10−50
  1. Root · 12 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 8 generations between
  3. 3 generations backK071000 MyrianIntrasense · 2007
  4. 2 generations backK091001 Myrian 1.4Intrasense · 2009
  5. 1 generation backK113620 Myrian 1.11Intrasense · 2012
  6. This deviceK130552 CT Pulmonary AnalysisQi Imaging, LLC · 2014
  7. Descendant · cites it directly · 1 of its ownK181892 Ziostation2Ziosoft, Inc. · 2018
  8. Descendant · 2 generations on · 0 of its ownK200315 Ziostation2Ziosoft, Inc. · 2020
Show all 12 generations
  1. Root · 12 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 11 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
  3. 10 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
  4. 9 generations backK023003 Imagechecker-CT WorkstationR2 Technology, Inc. · 2002
  5. 8 generations backK032748 VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc. · 2003 · Recalled
  6. 7 generations backK040305 VITREA2 Version 3.5Vital Images, Inc. · 2004
  7. 6 generations backK043333 VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc. · 2004 · Recalled
  8. 5 generations backK052632 VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc. · 2005 · Recalled
  9. 4 generations backK061624 Vitrea, Version 3.9Vital Images, Inc. · 2006 · Recalled
  10. 3 generations backK071000 MyrianIntrasense · 2007
  11. 2 generations backK091001 Myrian 1.4Intrasense · 2009
  12. 1 generation backK113620 Myrian 1.11Intrasense · 2012
  13. This deviceK130552 CT Pulmonary AnalysisQi Imaging, LLC · 2014

Most influential descendants

Showing 2 of 2 · See all
  • K181892Ziostation2Ziosoft, Inc. · 2018 · cites it directly1descendant
  • K200315Ziostation2Ziosoft, Inc. · 2020 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−12K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−11K960613GE Advantage Windows Review WorkstationGE Medical Systems1996—
−10K020483Advantage Workstation 4.1GE Medical Systems20022
−9K023003Imagechecker-CT WorkstationR2 Technology, Inc.2002—
−8K032748VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc.20032
−7K040305VITREA2 Version 3.5Vital Images, Inc.2004—
−6K043333VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc.20041
−5K052632VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc.20052
−4K061624Vitrea, Version 3.9Vital Images, Inc.20061
−3K071000MyrianIntrasense2007—
−2K091001Myrian 1.4Intrasense2009—
−1K113620Myrian 1.11Intrasense2012—
0 (this device)K130552CT Pulmonary AnalysisQi Imaging, LLC2014—
+1K181892Ziostation2Ziosoft, Inc.2018—
+2K200315Ziostation2Ziosoft, Inc.2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
198820
198910
199010
199150
199220
199320
199440
199560
199690
199780
1998110
199970
2000110
2001160
2002120
200360
2004140
2005100
200680
200770
200870
200920
201010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
202010
FIG. 1 — Lineage of K130552, 1991–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JAK device

  1. #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K083227Vida Pulmonary Workstation 2 (PW2)
Summary page 1
…Number VIDA VIDA Pulmonary K083227 CT PULMONARY ANALYSIS Workstaion 2.…
Vida Diagnostics, Inc.2008—
*K113620Myrian 1.11
Summary page 1
…NARY ANALYSIS Workstaion 2. Intrasense M .yrian vlii .2 K113620 ____________________ ________________________…
Intrasense2012—

Also cleared against K083227: 11 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K181892Ziostation2Ziosoft, Inc.20181

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 23 years and passes through 6 companies; a new generation was cleared every 12 months on median.
  • 40 of the 165 ancestors have a recall of any class.
  • Of its descendants, K181892 (Ziosoft, Inc., 2018) has gone furthest, with 1 descendant of its own.
  • 11 other devices also cite its predicate K083227.

How does its category compare?

All JAK devices

JAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · JAK

27in 2025

2007: 142008: 262009: 152010: 72011: 162012: 282013: 172014: 302015: 302016: 252017: 292018: 242019: 282020: 302021: 202022: 302023: 272024: 262025: 272026 (partial year): 21
2007high 30 (2014) · low 7 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JAK

141in 2025

2007: 27 days median2008: 42 days median2009: 31 days median2010: 92 days median2011: 155 days median2012: 121 days median2013: 132 days median2014: 200 days median2015: 140 days median2016: 129 days median2017: 96 days median2018: 114 days median2019: 94 days median2020: 112 days median2021: 145 days median2022: 131 days median2023: 139 days median2024: 141 days median2025: 141 days median2026 (partial year): 167 days median
2007high 200 (2014) · low 27 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JAK

17in 2025

2007: 112008: 162009: 292010: 512011: 342012: 232013: 112014: 102015: 282016: 442017: 332018: 102019: 52020: 82021: 152022: 92023: 92024: 202025: 172026 (partial year): 23
2007high 51 (2010) · low 5 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JAK

219in 2025

2007: 762008: 1202009: 1052010: 1192011: 2052012: 1922013: 4142014: 3082015: 4542016: 3652017: 3382018: 5432019: 2332020: 1772021: 2612022: 1992023: 3102024: 2122025: 219
2007high 543 (2018) · low 76 (2007)2025

MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200714271176
2008264216120
2009153129105
201079251119
20111615534205
20122812123192
20131713211414
20143020010308
20153014028454
20162512944365
2017299633338
20182411410543
201928945233
2020301128177
20212014515261
2022301319199
2023271399310
20242614120212
20252714117219
20262116723—

What is it indicated for?

Ziostation is an image processing workstation software package designed to run on standard PC hardware. It provides for the viewing, quantification, manipulation, communication, printing, and management of medical images. It is intended for use by trained medical professionals to aid in their reading and review of such data. In addition, Ziostation has the following indication:

The CT PULMONARY ANALYSIS software option is an independent image analysis software tool providing additional image process capabilities to the Ziostation system. The CT PULMONARY ANALYSIS option is intended to assist the physician in assessing possible airway obstruction.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K130552: CT Pulmonary Analysis.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K130552

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026