510(k) Report

510(k) · Cleared

Recalled · Class I · 2025

Z-800 Infusion System

K130690510(k) SpecialCleared Jun 12, 201390-day reviewClass II21 CFR 880.5725Recalls 9 (5 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Zyno Medical, LLC · FRN Pump, Infusion

Cleared on Jun 12, 2013 as substantially equivalent to K100705 (Zyno Medical, LLC, 2010) after a 90-day review. Its family tree reaches back 2 generations to 1995. 3 of the 6 devices in its family, counting itself, have a Class I recall. It has been recalled 9 times, including 5 Class I recalls.

Decided
Jun 12, 2013
Review
90 days
Class
Class II
Product code
FRN
Recalls
9 (5 Class I)
Predicates
1

Its longest line of descent runs back 2 generations to K950766 (1995). 5 ancestors in all. No later device cites it as a predicate yet. 3 of the 6 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year cleared 2007: 1 other ancestor2000: 1 other ancestor1999: 1 other ancestor, 1 with a Class I recall1K950766 · Sigma 8000 and Sigma 8002 · Sigma Intl. General Medical Apparatus, Inc. · 1995K100705 · Zyno Z-800 Infusion System Model Z-800 · Zyno Medical, LLC · 2010 · Class I recall19952000200520102015
Other ancestors, by generation 2 generations back: 3 other ancestors, 1 with a Class I recall1 K100705 · Zyno Z-800 Infusion System Model Z-800 · Zyno Medical, LLC · 2010 · Class I recallK950766 · Sigma 8000 and Sigma 8002 · Sigma Intl. General Medical Apparatus, Inc. · 19950
  1. Root · 2 generations backK950766 Sigma 8000 and Sigma 8002Sigma Intl. General Medical Apparatus, Inc. · 1995
  2. 1 generation backK100705 Zyno Z-800 Infusion System Model Z-800Zyno Medical, LLC · 2010 · Recalled (Class I)
  3. This deviceK130690 Z-800 Infusion SystemZyno Medical, LLC · 2013

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K950766Sigma 8000 and Sigma 8002Sigma Intl. General Medical Apparatus, Inc.1995—
−1K100705Zyno Z-800 Infusion System Model Z-800Zyno Medical, LLC2010Class I
0 (this device)K130690Z-800 Infusion SystemZyno Medical, LLC2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199911
200010
200710
FIG. 1 — Lineage of K130690, 1995–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRN device

  1. #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K100705Zyno Z-800 Infusion System Model Z-800
Summary page 1
…tric Infusion Pump Classification Name: Infusion Pump Product code: FRN 880.5725 Establishment Registration Number: 3006575795 Predicate Devices Z-800 Infusion System (K100705) Intended Use K300 JUN 1 2 2013 The Z-800 Infusion system is intended to provide intravenous infusion of parenteral fluids, b…
Zyno Medical, LLC2010Class I

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (3 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 7, 2025Class IZ-1867-2025Software design (manufacturing process)Unreleased software versions were installed on distributed devices without verification or validation.
May 7, 2025Class IZ-1868-2025Software design (manufacturing process)Unreleased software versions were installed on distributed devices without verification or validation.
May 7, 2025Class IZ-1865-2025Software design (manufacturing process)Unreleased software versions were installed on distributed devices without verification or validation.
May 7, 2025Class IZ-1866-2025Software design (manufacturing process)Unreleased software versions were installed on distributed devices without verification or validation.
Oct 18, 2024Class IIZ-0506-2025Device DesignPotential for the battery to deplete over time from self-discharge and internal parasitic leakage current despite being continuously plugged into AC mains.
Sep 30, 2024Class IIIZ-0523-2025Software design (manufacturing process)For the Z-800WF pumps, the WiFi software was not compatible with the pump software that had been loaded in accordance with ongoing correction Z-1183-2024.
Sep 13, 2024Class IZ-0005-2025Process change controlThere is a defect in the air-in-line software algorithm.
Jun 4, 2024Class IIZ-2263-2024Process controlZyno Medical has found that certain Z800, Z800F, Z800W, and Z800WF pumps have faulty power supply modules that will not provide a charge to the rechargeable battery within the pump. This may lead to the battery having insufficient or no…
Dec 20, 2023Class IIZ-1183-2024Software designWhen utlizing the patient query feature on the Zyno Medical Z-800WF pumps with software version 5.2.05, the alarm volume may inadvertently revert from a higher volume setting to a low one, causing potential delays in therapy and in…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K100705Zyno Z-800 Infusion System Model Z-800Zyno Medical, LLC · 2010 · Direct predicate · ◆ on the line of descent in FIG. 15 Class I recalls
  • K991501Acclaim Infusion PumpAbbott Laboratories · 1999 · 2 generations back · ◆ in the 1999 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 18 years and passes through 2 companies; a new generation was cleared every 15.3 years on median.
  • 3 of the 5 ancestors have a recall of any class; 2 have a Class I recall.

How does its category compare?

All FRN devices

FRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · FRN

8in 2025

2007: 122008: 82009: 92010: 32011: 32012: 42013: 62014: 62015: 32016: 32017: 32018: 32019: 22020: 12021: 22022: 62023: 72024: 52025: 82026 (partial year): 2
2007high 12 (2007) · low 1 (2020)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRN

172in 2025

2007: 102 days median2008: 89 days median2009: 66 days median2010: 93 days median2011: 103 days median2012: 217 days median2013: 312 days median2014: 172 days median2015: 232 days median2016: 301 days median2017: 305 days median2018: 267 days median2022: 268 days median2023: 265 days median2024: 103 days median2025: 172 days median
2007high 312 (2013) · low 66 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRN

7in 2025

2007: 152008: 242009: 1022010: 372011: 692012: 42, 2 Class I2013: 22, 3 Class I2014: 4, 3 Class I2015: 52016: 7, 1 Class I2017: 132018: 12019: 18, 1 Class I2020: 16, 5 Class I2021: 3, 2 Class I2022: 22023: 16, 10 Class I2024: 9, 4 Class I2025: 7, 4 Class I2026 (partial year): 11, 2 Class I
2007high 102 (2009) · low 1 (2018)2026

Class I (37 since 2007) Class II/III not classified

Adverse event reports per year · FRN

52,792in 2025

2007: 1,0862008: 8,2612009: 1,9522010: 6,1332011: 41,3672012: 15,4822013: 40,0822014: 94,1802015: 26,7422016: 16,5602017: 12,0602018: 16,5912019: 15,8502020: 94,1862021: 199,3422022: 888,0202023: 165,8382024: 57,7302025: 52,792
2007high 888,020 (2022) · low 1,086 (2007)2025

MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200712102151,086
2008889248,261
20099661021,952
2010393376,133
201131036941,367
2012421742 (2)15,482
2013631222 (3)40,082
201461724 (3)94,180
20153232526,742
201633017 (1)16,560
201733051312,060
20183267116,591
20192—18 (1)15,850
20201—16 (5)94,186
20212—3 (2)199,342
202262682888,020
2023726516 (10)165,838
202451039 (4)57,730
202581727 (4)52,792
20262—11 (2)—

What is it indicated for?

The Z-800 Infusion system is intended to provide

intravenous infusion of parenteral fluids, blood and blood products to a patient

under the direction or supervision of physician or other certified health care

professional.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K130690: Z-800 Infusion System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K130690

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026